TROUBLESHOOTING (cont.) |
|
|
PROBLEM | PROBABLE CAUSE | REMEDY |
Product will not dispense | 1. No water | Water lines and valves to the |
|
| dispenser must be open. |
| 2. No power or incorrect voltage to | (A1) Check the terminal block for |
| the dispenser | 120 volts across the black and |
|
| white terminals on two wire 120 |
|
| volt dispenser. |
|
| (A2) Check the terminal block for |
|
| 120 volts across the red and |
|
| white terminal and the black and |
|
| white terminal on three wire |
|
| 120/240 volt dispenser. |
|
| (A3) Check the terminal block for |
|
| 240 volts across the white and |
|
| black terminal on two wire 240 |
|
| volt dispenser. |
|
| (B) Check circuit breakers or |
|
| fuses. |
| 3. Dispense switch | Refer to Service - Dispense |
|
| Switch for testing procedure. |
|
| See page 18 |
| 4. Dispense solenoid valve | Refer to Service - Dispense |
| (Hot or Cold) | solenoid valve for testing proce- |
|
| dures. See page 30 or 31 |
| 5. Solenoid valve (Inlet) | Refer to Service - Solenoid Valve |
|
| (Inlet) for testing procedures. |
|
| See page 32 |
| 6. Level control board and probe | Refer to Service - Level Control |
|
| Board and Probe for testing |
|
| procedures. See page 26 |
| 7. Overflow protection switch | Refer to Service - Overflow |
|
| protection switch for testing |
|
| procedures. See page 28 |
| 8. Auger drive | Refer to Service - Auger Drive. |
|
| See page 12 |