TROUBLESHOOTING (cont.)
PROBLEM
Product will not dispense (cont.)
PROBABLE CAUSE
9. Water strainer
10. Lime
CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral
REMEDY
(A)Direction of flow arrow must be pointing towards dispenser.
(B)Remove the flow control and check for obstructions. Clear or replace.
Inspect the tank assembly for excessive lime deposits. Delime as required.
Water is not hot
1. | Limit thermostat | Refer to Service - Limit Thermo- |
CAUTION - Do not eliminate or | stat for testing procedures. See | |
bypass limit thermostat. Use only | page 27 | |
BOM replacement part |
| |
#29329.1000 |
| |
2. | Control thermostat (mechanical | Refer to Service - Control Thermo- |
or electronic) | stat for testing procedures. See | |
|
| page 16 |
3. | Tank Heater | Refer to Service - Tank Heater for |
|
| testing procedures. See page 33 |
4. | Tank heater switch | Refer to Service - Tank Heater |
|
| Switch for testing procedures. See |
|
| page 34 |
Spitting or excessive steaming
1. Lime
CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral
Inspect tank assembly for exces- sive lime deposits. Delime as required.
2. Control thermostat (mechanical | Refer to Service - Control Thermo- |
or electronic) | stat for testing procedures. See |
| page 16 |
8 | 27591 061500 |
|