TROUBLESHOOTING (cont.)
PROBLEM
Brew cycle will not start (cont.)
PROBABLE CAUSE
6.Brew Timer
7.Brew Solenoid Valve
REMEDY
Refer to Service - Brew Timer for testing procedures. See page 16 or 17.
Refer to Service - Brew Solenoid Valve for testing procedures. See page 15.
Water is not hot
1. Limit Thermostat | Refer to Service - Limit Thermostat |
CAUTION - Do not eliminate or by- | for testing procedures. See page |
pass limit thermostat or thermal | 20. |
| |
part #29329.1000 |
|
2. Control Thermostat | Refer to Service - Control Thermo- |
| stat for testing procedures. See |
| page 19. |
Dilution cycle will not start
Inconsistent beverage level in dispenser
3. Tank Heater
1.ON/OFF (UNSWEET/OFF/SWEET) Switch
2.Start Switch
1.Syphon System
2.Lime Build-up
CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral
Refer to Service - Tank Heater for testing procedures. See page 23.
Refer to Service - ON/OFF Switch for testing. See page 21. For OFF/ SELECTOR switch See page 25.
Refer to Service - Start Switch for testing procedures. See page 22.
The brewer must be level or slightly lower in front to syphon properly.
Inspect the tank assembly for ex- cessive lime deposits. Delime as required.
3. Water Pressure | The water pressure to the brewer |
| must be at least 20 psi (138 kPa). |
Page 10 | 10288 031604 |
|