TEA BREWING

1.Begin each brew cycle with a clean empty brew funnel and server. (Be sure the server lid doesnÕt interfere with the flow of dilution water.)

2.Insert a BUNN¨ filter into the funnel.

3.Pour the packet of loose fresh tea leaves into the filter. Approximately three to five ounces is recommended for three gallons of beverage.

4.Level the bed of tea leaves by gently shaking.

5.Slide the funnel into the funnel rails until it stops.

6.Place the ON/OFF switch in the ÒONÓ position. (For brewers with a sweetener, place the UNSWEET/OFF/ SWEET switch in the "SWEET" or "UNSWEET" position.)

7.Momentarily press the START switch.

CAUTION - The funnel contains hot liquids. Remove funnel slowly.

8.Carefully remove the brew funnel and discard the used filter when tea no longer drips from the funnel tip.

9.Place the ON/OFF (UNSWEET/OFF/SWEET) switch in the "OFF" position to prevent a false start.

10.Fresh tea is available at the faucet.

Page 8

10288 031604

 

Image 8
Contents TU3Q Phone 217 529-6601 FAX 217Introduction ContentsBUNN-O-MATIC Commercial Product Warranty #03408.0002 #03409.0002 #03408.0000 #03536.0000 #03409.0000 User Notices#00831.0000 #00656.0000 Electrical Hook-Up Electrical RequirementsPlumbing Requirements Initial SET-UP Auto Sweetener SET-UPAdjusting Brew Volumes Auto Sweetener SET-UPOperating Controls CleaningAuto Sweetener Cleaning TEA Brewing Remedy TroubleshootingProblem Probable Cause Troubleshooting ProblemProbable Cause RemedyProblem Probable Cause Beverage overflows dispenser Brew Timer Dripping from sprayheadSyphon System Lime Build-up DispenserProblem Probable Cause Remedy Service Component AccessService Test Procedures Disconnect the brewer from the power sourceBrew Solenoid Valve Solenoid valveBrew Timer Early Models Wiring Diagram and check the wiring harnessService Digital Brew Timer Late Models If voltage is as described, proceed to #7Digital Timer Wiring Control Thermostat Control ThermostatLimit Thermostat Limit ThermostatON/OFF Switch Refer to when reconnecting the wires LocationSwitch terminals On the switch terminalStart Switch Start SwitchTank Heater Sweetener Solenoid Valve Optional OFF/SELECTOR Switch Schematic Wiring Diagram TU3Q Volts AC 2 Wire Single PhaseWire Volts AC