Bunn TU3Q service manual Problem Probable Cause

Page 11

TROUBLESHOOTING (cont.)

 

 

PROBLEM

PROBABLE CAUSE

REMEDY

Consistently high or low beverage level in the dispenser

Spitting or excessive steaming

1.External Strainer/Flow Control (.750 GPM)

1. Lime Build-up

CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral build-up on stainless steel surfaces can ini- tiate corrosive reactions resulting in serious leaks.

(A)Direction of flow arrow must be pointing towards brewer.

(B)Remove the strainer/flow con- trol and check for obstructions. Clear or replace.

Inspect tank assembly for excessive lime deposits. Delime as required.

 

2.

Control Thermostat

Refer to Service - Control Thermo-

 

 

 

stat for testing procedures. See

 

 

 

page 19.

Drip-out time too long

1. Funnel Tip

The brew funnel should be cleaned

 

 

 

thoroughly before each brew cycle

 

 

 

to lessen the chance of tea leaf par-

 

 

 

ticles clogging the drip-out tip.

Sweetener is not working

1.

Sweetener box is empty

Check the Sweetener box to make

 

 

 

sure it is not out of product.

 

2. Flow Adjustment screw is closed

Check the Flow Adjustment screw

 

 

 

to make sure the valve has not

 

 

 

closed.

 

3.

Solenoid is defective

Refer to Service -Sweetener Sole-

 

 

 

noid Valve for testing procedures.

 

 

 

See page 24.

 

3.

The Pump is defective

Check the manufacturers warranty

 

 

 

for additional information on test-

 

 

 

ing and replacement of a defective

 

 

 

pump.

Page 11

10288 031604

 

Image 11
Contents Phone 217 529-6601 FAX 217 TU3QIntroduction ContentsBUNN-O-MATIC Commercial Product Warranty #03408.0002 #03409.0002 #03408.0000 #03536.0000 #03409.0000 User Notices#00831.0000 #00656.0000 Electrical Hook-Up Electrical RequirementsPlumbing Requirements Auto Sweetener SET-UP Initial SET-UPAuto Sweetener SET-UP Adjusting Brew VolumesOperating Controls CleaningAuto Sweetener Cleaning TEA Brewing Remedy TroubleshootingProblem Probable Cause Remedy TroubleshootingProblem Probable CauseProblem Probable Cause Dispenser Beverage overflows dispenser Brew TimerDripping from sprayhead Syphon System Lime Build-upProblem Probable Cause Remedy Component Access ServiceSolenoid valve ServiceTest Procedures Disconnect the brewer from the power source Brew Solenoid ValveWiring Diagram and check the wiring harness Brew Timer Early ModelsIf voltage is as described, proceed to #7 Service Digital Brew Timer Late ModelsDigital Timer Wiring Control Thermostat Control ThermostatLimit Thermostat Limit ThermostatOn the switch terminal ON/OFF SwitchRefer to when reconnecting the wires Location Switch terminalsStart Switch Start SwitchTank Heater Sweetener Solenoid Valve Optional OFF/SELECTOR Switch Volts AC 2 Wire Single Phase Schematic Wiring Diagram TU3QVolts AC Wire