Bunn TU3Q service manual Electrical Requirements, Plumbing Requirements, Electrical Hook-Up

Page 4

ELECTRICAL REQUIREMENTS

CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up.

120V model brewers require 2-wire, grounded service rated 120 volts ac, 15 amp, single phase, 60 Hz. "A" model brewers require 2-wire, grounded service rated 230 volts ac, 10 amp, single phase, 50 Hz. "B" model brewers require 2-wire, grounded service rated 100 volts ac, 15 amp, single phase, 60 Hz. Proceed as follows:

Electrical Hook-Up

CAUTION - Improper electrical installation will damage electronic components.

1.An electrician must provide electrical service as specified.

2.Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.

3.Remove top cover from the brewer.

4.Rotate the control thermostat knob fully counterclockwise to the "OFF" position and replace the top cover.

5.Connect the brewer to the power source.

6.If plumbing is to be hooked up later be sure the brewer is disconnected from the power source. If plumbing has been hooked up, the brewer is ready for Initial Set-Up.

PLUMBING REQUIREMENTS

These brewers must be connected to a cold water system with operating pressure between 20 and 90 psi (138 and 621 kPa) from a 1Ú2" or larger supply line. A shut-off valve should be installed in the line before the brewer. Install a regulator in the line when pressure is greater than 90 psi (621kPa) to reduce it to 50 psi (345 kPa). The water inlet fitting is 1Ú4" flare.

NOTE: Bunn-O-Matic recommends 1Ú4" copper tubing for installations of less than 25 feet and 3Ú8" for more than 25 feet from the 1Ú2" water supply line. A tight coil of copper tubing in the water line will facilitate moving the brewer to clean the countertop. Bunn-O-Matic does not recommend the use of a saddle valve to install the brewer. The size and shape of the hole made in the supply line by this type of device may restrict water flow.

This equipment must be installed to comply with the Basic Plumbing Code of the

Building Officials and Code Administrators International, Inc. (BOCA)

and the Food Service Sanitation Manual of the Food and Drug Administration (FDA).

Standard Flow Control

Quiet Flow Control

Page 4

10288 031604

 

Image 4
Contents TU3Q Phone 217 529-6601 FAX 217BUNN-O-MATIC Commercial Product Warranty ContentsIntroduction #00831.0000 #00656.0000 User Notices#03408.0002 #03409.0002 #03408.0000 #03536.0000 #03409.0000 Plumbing Requirements Electrical RequirementsElectrical Hook-Up Initial SET-UP Auto Sweetener SET-UPAdjusting Brew Volumes Auto Sweetener SET-UPAuto Sweetener Cleaning CleaningOperating Controls TEA Brewing Problem Probable Cause TroubleshootingRemedy Troubleshooting ProblemProbable Cause RemedyProblem Probable Cause Beverage overflows dispenser Brew Timer Dripping from sprayheadSyphon System Lime Build-up DispenserProblem Probable Cause Remedy Service Component AccessService Test Procedures Disconnect the brewer from the power sourceBrew Solenoid Valve Solenoid valveBrew Timer Early Models Wiring Diagram and check the wiring harnessService Digital Brew Timer Late Models If voltage is as described, proceed to #7Digital Timer Wiring Control Thermostat Control ThermostatLimit Thermostat Limit ThermostatON/OFF Switch Refer to when reconnecting the wires LocationSwitch terminals On the switch terminalStart Switch Start SwitchTank Heater Sweetener Solenoid Valve Optional OFF/SELECTOR Switch Schematic Wiring Diagram TU3Q Volts AC 2 Wire Single PhaseWire Volts AC