SERVICE (cont.) |
|
|
|
SWEETENER SOLENOID VALVE (OPTIONAL) | 5. | Check the solenoid valve for coil action. Connect | |
|
| the brewer to the power source, place the | |
|
| OFF/SELECTOR switch in the ÒSWEETÓ position | |
|
| and momentarily place the start switch in the lower | |
|
| position and release. At the start of a brew cycle, | |
|
| listen carefully in the vicinity of the solenoid valve | |
|
| for a ÒclickingÓ sound as the coil magnet attracts | |
|
| and at the end of the brew cycle when the plunger | |
|
| is released. |
|
| 6. | Disconnect the brewer from the power source. | |
| If the sound is heard as described and sweetener will | ||
P2844 | not pass through the solenoid valve, there may be a | ||
FIG. 18 SWEETENER SOLENOID VALVE | blockage in the sweetener line before or after the so- | ||
Location: | lenoid valve or, the solenoid valve may require inspec- | ||
tion for wear, and removal of particles. |
| ||
Viewing the brewer from the front, the sweetener | If the sound is not heard as described, replace the | ||
solenoid is mounted on the left side of the solenoid | solenoid valve. |
| |
mounting bracket which is secured to the bottom base |
|
|
|
housing. | Removal and Replacement: |
| |
Test Procedure: | 1. | Remove all wires from the solenoid valves. |
|
2. | Turn off the sweetener supply to the brewer. |
| |
1. Disconnect the brewer from the power source. | 3. | Disconnect the water lines to and from the sole- | |
2. With a voltmeter, check the voltage across the |
| noid valves. |
|
brown/white and white/violet wires on the sweet- | 4. | Remove the two | |
ener solenoid terminals when the OFF/SELECTOR |
| mounting bracket to the trunk base. |
|
switch is in the ÒSWEETÓ position and the start | 5. | Lift out the bracket. |
|
switch is momentarily placed in the lower posi- | 6. | Remove the two | |
tion. Connect the brewer to the power source. |
| ing the solenoid valve to the mounting bracket. | |
After the approximate setting on the delay dial, | 7. | Securely install the new solenoid valve to the | |
the indication must be: |
| mounting bracket. |
|
a) 120 volts ac for two wire 120 volt models. | 8. | Attach the mounting bracket to the trunk base. | |
b) 230 volts ac for two wire 230 volt models. | 9. | Securely fasten the sweetener and water lines to | |
c) 100 volts ac for two wire 100 volt models, re- |
| and from the solenoid valves. |
|
main for the approximate setting on the dilution | 10. | Refer to Fig. 19 when reconnecting the wires. | |
dial, and then return to its previous indication. |
|
|
|
3. Disconnect the brewer from the power supply. |
|
|
|
If voltage is present as described, proceed to #4. |
| WHI/VIO to Brew Timer TL1 | |
| WHI/VIO to Brew Solenoid | ||
If voltage is not present as described, refer to the Wir- |
| ||
|
|
| |
ing Diagrams and check the wiring harness. |
|
|
|
4. Remove both wires from the coil and check for |
| BRN/WHI to |
|
| Selector Switch |
| |
continuity across the coil terminals. If continuity |
| SWEETENER |
|
is present as described, reconnect the brown/white |
|
| |
| SOLENOID (OPTIONAL) |
| |
and white/violet wires and proceed to #5. |
|
|
|
If continuity is not present as described, replace the |
| P2843 | |
solenoid valve. |
| FIG.19 SOLENOID VALVE TERMINALS |
|
Page 24 | 10288 | 031604 | |
|
|