Bunn TU3Q Service Digital Brew Timer Late Models, If voltage is as described, proceed to #7

Page 17

SERVICE (cont.)

DIGITAL BREW TIMER (Late Models)

P2200.50

FIG. 6 DIGITAL BREW TIMER

Location:

The timer is located inside the hood, on the left side.

Test Procedure.

NOTE: Do not remove or install wires while timer board is installed. Pressure applied to one side may cause damage to the board.

1.Disconnect the brewer from the power source and remove the top cover.

2.Remove the two #8-32 screws securing circuit board to the mounting bracket.

3.Remove circuit board and spacers (as required).

4.With a voltmeter, check the voltage across termi- nals TL1 and TL2 when the "ON/OFF" switch is in the "ON" position. Connect the brewer to the power source. The indication must be:

a)120 volts ac for two wire 120 volt models

b)230 volts ac for two wire 230 volt models.

c)100 volts ac for two wire 100 volt models.

5.Disconnect the brewer from the power source.

If voltage is present as described, proceed to #6.

If voltage is not present as described, refer to the Wiring Diagrams and check the brewer wiring har- ness.

6.With a voltmeter, check the voltage across termi- nals TL1 and TL4 when the "ON/OFF" switch is in the "ON" position. Connect the brewer to the power source. The indication must be 0 volts.

If voltage is as described, proceed to #7.

If voltage is not as described, disconnect the brewer from the power source and replace the timer.

7.With a voltmeter, check the voltage across termi- nals TL1 and TL4 when the "ON/OFF" switch is in the "ON" position. Connect the brewer to the power source and press the "START" switch. The indica- tion must be as follows:

a)120 volts ac for two wire 120 volt models.

b)230 volts ac on two wire 230 volt models.

c)100 volts ac for two wire 100 volt models.

If voltage is present as described, the brew timer is operating properly. Reset the timer as required, to obtain the desired brew volume.

If voltage is not present as described, disconnect the brewer from the power source and replace the timer.

Removal and Replacement:

1.Remove the two #8-32 screws securing circuit board to the mounting bracket.

2.Remove circuit board and spacers (as required).

3.Remove all wires from the timer.

4.Attach all wires to the replacement timer board prior to installation to the component mounting bracket. Refer to FIG. 7 when reconnecting the wires.

5.Install new circuit board with spacers (as re- quired) to the hood.

6.Adjust the timer as described below.

Timer Setting:

NOTE: Prior to setting or modifying volumes, check that the brewer is connected to water supply, the tank is properly filled, and a funnel and server are in place. NOTE: All volume settings must be done with the sprayhead installed.

1.Modifying brew volumes. To modify a brew vol- ume, first check that the SET/LOCK switch is in the ÒSETÓ position on the circuit board.

Page 17

10288 071000

 

Image 17
Contents Phone 217 529-6601 FAX 217 TU3QIntroduction ContentsBUNN-O-MATIC Commercial Product Warranty #03408.0002 #03409.0002 #03408.0000 #03536.0000 #03409.0000 User Notices#00831.0000 #00656.0000 Electrical Hook-Up Electrical RequirementsPlumbing Requirements Auto Sweetener SET-UP Initial SET-UPAuto Sweetener SET-UP Adjusting Brew VolumesOperating Controls CleaningAuto Sweetener Cleaning TEA Brewing Remedy TroubleshootingProblem Probable Cause Problem TroubleshootingProbable Cause RemedyProblem Probable Cause Dripping from sprayhead Beverage overflows dispenser Brew TimerSyphon System Lime Build-up DispenserProblem Probable Cause Remedy Component Access ServiceTest Procedures Disconnect the brewer from the power source ServiceBrew Solenoid Valve Solenoid valveWiring Diagram and check the wiring harness Brew Timer Early ModelsIf voltage is as described, proceed to #7 Service Digital Brew Timer Late ModelsDigital Timer Wiring Control Thermostat Control ThermostatLimit Thermostat Limit ThermostatRefer to when reconnecting the wires Location ON/OFF SwitchSwitch terminals On the switch terminalStart Switch Start SwitchTank Heater Sweetener Solenoid Valve Optional OFF/SELECTOR Switch Volts AC 2 Wire Single Phase Schematic Wiring Diagram TU3QVolts AC Wire