Installation and Operation, cont’d
RGBS from RGBS
OUTPUTS
R | G | B |
/Y | ||
H | V | S |
8
9
RGB or HD component
Remote
The default protocol is 9600 baud, 1 stop bit, no parity, and no flow control.
The rear panel
Pin |
| Description |
1 | Input #1 | Contact closure |
2 | Tx | Transmit data |
3 | Rx | Receive data |
4 | Input #2 | Contact closure |
5 | Gnd | Signal ground |
|
|
|
6 | Input #3 | Contact closure |
7 | Input #4 | Contact closure |
8 | – | No connection |
9 | Hardwired IR | IR input |
The Remote connector also provides a way to select an input using a remote contact closure device. Contact closure control uses pins on the Remote connector that are not used by the
To select a different input number using a contact closure device, momentarily short the pin for the desired input number to logic ground (pin 5). To force one of the inputs to be always selected, leave the short to logic ground in place. The short overrides front panel input selections.