Carrier 30XW325-400 manual A30-4745, Standard 30XW Unit Dimensions

Page 12

Dimensions

30XW UNIT DIMENSIONS

a30-4745

SEE NIH EVAPORATOR

DETAIL FOR NOZZLE

MEASUREMENTS

SUCTION

END

SEE NIH CONDENSER

DETAIL FOR NOZZLE

MEASUREMENTS

EVAPORATOR

CONDENSER

MLV (OPTIONAL)

MLV (OPTIONAL)

DISCHARGE END

STANDARD 30XW UNIT DIMENSIONS

30XW UNIT

OPERATING

MOUNTING LOCATION WEIGHT, lb [kg]

 

DIMENSIONS (ft-in. [mm])

SIZE

WEIGHT, lb [kg]

1

2

3

4

 

A

 

B

 

C

325

14,319 [6495]

3734 [1694]

3828 [1736]

3337 [1514]

3420 [1551]

6-3/8

[1837]

6-3/8

[1837]

3/8

[9.53]

350

14,515 [6584]

3785 [1717]

3880 [1760]

3383 [1535]

3467 [1573]

6-3/8

[1837]

6-3/8

[1837]

3/8

[9.53]

400

14,759 [6695]

3848 [1745]

3946 [1790]

3439 [1560]

3526 [1599]

6-3/8

[1837]

6-3/8

[1837]

3/8

[9.53]

NOTES:

1.Weights shown for standard chiller (2 pass with NIH, victaulic waterboxes).

2.See page 14 for unit mounting locations.

30XW UNIT AND WATERBOX DIMENSIONS

LEGEND

MLV — Minimum Load Valve

MWB — Marine Waterbox

NIH — Nozzle-In-Head

SSV — Suction Service Valve

CONNECTIONS

PASSES

WATERBOX

NOZZLE

D

E

F

 

MAX UNIT OPERATING WEIGHT lb [kg]

 

 

(EVAP/COND)

TYPE

ft-in. [mm]

ft-in. [mm]

ft-in. [mm]

325

350

400

 

 

NIH/NIH

Victaulic

13-33/4[4057]

 

 

 

14,319 [6495]

14,515 [6495]

14,759 [6695]

 

 

Flange

13-91/16[4193]

 

 

 

14,651 [6646]

14,847 [6646]

15,091 [6845]

 

 

 

 

 

 

 

 

NIH/MWB

Victaulic

 

 

 

 

14,498 [6576]

14,694 [6576]

14,938 [6776]

Same Ends

 

Flange

 

3-113/8[1210]

6-611/16

[1999]

14,739 [6685]

14,935 [6685]

15,179 [6885]

 

 

 

 

MWB/NIH

Victaulic

13-115/8[4258]

14,489 [6572]

14,685 [6572]

14,929 [6772]

 

 

 

 

 

 

 

Flange

 

 

 

14,746 [6689]

14,768 [6689]

15,012 [6809]

 

 

 

 

 

 

 

 

 

MWB/MWB

Victaulic

 

 

 

 

14,668 [6653]

14,864 [6653]

15,108 [6853]

 

2 Pass

Flange

 

 

 

 

14,834 [6729]

15,030 [6729]

15,274 [6928]

 

 

 

 

 

 

 

NIH/NIH

Victaulic

13-65/16[4123]

 

 

 

14,319 [6495]

14,515 [6495]

14,759 [6695]

 

 

 

 

 

 

 

Flange

14-47/16[4380]

 

 

 

14,651 [6646]

14,847 [6646]

15,091 [6845]

 

 

 

 

 

 

 

 

NIH/MWB

Victaulic

14-23/16[4323]

 

 

 

14,498 [6576]

14,694 [6576]

14,938 [6776]

 

 

Flange

14-615/16[4443]

 

 

 

14,739 [6685]

14,935 [6685]

15,179 [6885]

 

 

 

 

 

 

 

 

MWB/NIH

Victaulic

14-213/16[4339]

 

 

 

14,489 [6572]

14,685 [6572]

14,929 [6772]

Opposite Ends

 

Flange

14-83/16[4475]

3-113/8[1210]

6-611/16

[1999]

14,746 [6689]

14,768 [6689]

15,012 [6809]

 

 

 

MWB/MWB

Victaulic

14-1011/16[4539]

14,668 [6653]

14,864 [6653]

15,108 [6853]

 

 

 

 

 

 

 

Flange

 

 

 

14,834 [6729]

15,030 [6729]

15,274 [6928]

 

 

NIH/NIH

Flange

14-55/8[4410]

 

 

 

14,828 [6726]

15,024 [6726]

15,268 [6925]

 

1 or

NIH/MWB

Flange

 

 

 

 

15,223 [6905]

14,768 [6896]

15,012 [6809]

 

3 Pass

MWB/NIH

Flange

14-1011/16[4539]

 

 

 

15,244 [6915]

15,440 [6894]

15,684 [7114]

 

 

MWB/MWB

Flange

 

 

 

 

15,581 [7067]

15,777 [7063]

16,021 [7267]

NOTES:

1.Operating weight includes weight of water, refrigerent, and oil.

2. Denotes center of gravity.

3.Dimensions shown in ft-in. [mm] unless noted.

4.The recommended service clearance around the machine is 3 ft [914.4 mm].

5.Victaulic nozzles are standard on all units. A flow switch can be factory-installed in evaporator inlet victaulic nozzle.

6.Maximum fluid side pressure of condenser or evaporator is 150 psig [1034 kPa] (standard) or 300 psig [2068 kPa] (optional).

7.Operating weight includes weight of water, refrigerant, and oil.

12

Image 12
Contents Features/Benefits Small footprintTable of contents Optional suction service valves Refrigerant isolation valvesMarine container shipment Heat exchangersTouch Pilot Display Smooth Rotary CompressorTWIN-SCREW Design Optional Navigator DisplayModel number nomenclature A30-4744Capacity ratings Physical data 30XW325-400 Unit Physical Data English30XW325-400 Unit Physical Data SI Options and accessories Factory-installed optionsA30-4684.eps A30-4685Field-supplied and field-installed insulation Field-installed accessoriesFIELD-SUPPLIED and FIELD-INSTALLED Insulation A30-4686Dimensions 30XW Unit DimensionsStandard 30XW Unit Dimensions 30XW Unit and Waterbox DimensionsA30 4755A30-4747 A30-4748A30-4725 A30-4751A30-4749 A30-4752Selection procedure Performance dataEvaporator and Condenser Flow Rates 30XW325-400 Evaporator Marine Waterbox 30XW325-400 Evaporator NIH FlangeA30-4694 30XW325-400 Evaporator NIH Victaulic30XW325-400 Condenser Marine Waterbox A30-4696 30XW325-400 Condenser NIH Flange30XW325-400 Condenser NIH Victaulic Controls MicroprocessorControl sequence Safeties Typical control wiring schematics 30XW Unit Control Wiring SchematicA30-4697 Application data Water loop volume Variable evaporator flow ratesEvaporator fouling factor Condenser minimum flow rateElectric utility interests Wiring Typical Piping and Wiring for 30XW Evaporator and CondenserA30-4700 Standard Single Input Power Configuration Electrical dataOptional Dual Input Power Configuration NO. Power ICF REC Fuse Control Circuit UnitSupply Compressor Electrical Data 30HX Unit Voltage Compressor Compressor a Compressor B SizeRLA LRA WD RLAGuide specifications Hvac Guide SpecificationsGuide specifications Page Carrier Corporation Syracuse, New York