Carrier 30XW325-400 manual Model number nomenclature, A30-4744

Page 5

Model number nomenclature

 

 

 

30XW

325

6

– –

– 4 – 3 B

 

 

30XW – AquaForce® Water-Cooled

 

 

 

 

Packaging/Charging Options

 

 

 

Screw Chiller

 

 

 

 

B

R-134a Refrigerant with Bag (Std)

 

 

 

 

 

 

 

 

C

R-134a Refrigerant with Crate Over Bag

 

 

 

 

 

 

 

 

D

Nitrogen Refrigerant with Bag

Design Series

 

 

 

 

F

Nitrogen Refrigerant with Crate Over Bag

Unit Size (Nominal Tons) (kW)

 

 

 

 

Controls/Communications Options

325 – 325 (1133)

 

 

 

 

-

Navigator™ Display

350 – 350 (1206)

 

 

 

 

0

Navigator Display, EMM

400 – 400 (1354)

 

 

 

 

1

Navigator Display, GFCI Service Option

 

 

 

 

 

 

 

 

2

Navigator Display, EMM, GFCI Service Option

Voltage

 

 

 

 

3

Touch Pilot™ Display (Std)

 

 

 

 

4

Touch Pilot, EMM

1

575-3-60

 

 

 

 

5

Touch Pilot, GFCI Service Option

2

380-3-60

 

 

 

 

6

Touch Pilot, EMM, GFCI Service Option

4

230-3-60

 

 

 

 

7

Navigator Display, BACnet™ Translator

6

460-3-60

 

 

 

 

8

Navigator Display, EMM, BACnet Translator

7

200-3-60

 

 

 

 

9

Navigator Display, GFCI Service Option,

 

 

 

 

 

 

 

 

B

BACnet Translator

Condenser Options

 

 

 

 

Navigator Display, EMM, GFCI Service Option,

 

 

 

 

 

 

BACnet Translator

-

2

Pass, NIH, 150 psig (1034 kPa), Victaulic, Discharge Connections (Std)

C

Touch Pilot Display (Std), BACnet Translator

0

2

Pass, NIH, 150 psig (1034 kPa), Victaulic, Suction Connections

 

D

Touch Pilot Display, EMM, BACnet Translator

1

2

Pass, NIH, 150 psig (1034 kPa), Flange, Discharge Connections

 

F

Touch Pilot Display, GFCI Service Option,

2

2

Pass, NIH, 150 psig (1034 kPa), Flange, Suction Connections

 

 

 

 

BACnet Translator

3

2

Pass, NIH, 300 psig (2068 kPa), Victaulic, Discharge Connections

 

G

Touch Pilot Display, EMM, GFCI Service Option,

4

2

Pass, NIH, 300 psig (2068 kPa), Victaulic, Suction Connections

 

 

 

BACnet Translator

5

2

Pass, NIH, 300 psig (2068 kPa), Flange, Discharge Connections

 

H

Navigator Display, LON Translator

6

2

Pass, NIH, 300 psig (2068 kPa), Flange, Suction Connections

 

 

J

Navigator Display, EMM, LON Translator

7

2

Pass, MWB, 150 psig (1034 kPa), Victaulic, Discharge Connections

 

K

Navigator Display, GFCI Service Option,

8

2

Pass, MWB, 150 psig (1034 kPa), Victaulic, Suction Connections

 

 

 

LON Translator

9

2

Pass, MWB, 300 psig (2068 kPa), Victaulic, Discharge Connections

 

L

Navigator Display, EMM, GFCI Service Option,

B

2

Pass, MWB, 300 psig (2068 kPa), Victaulic, Suction Connections

 

 

 

LON Translator

C

2

Pass, MWB, 150 psig (1034 kPa), Flange, Discharge Connections

 

M

Touch Pilot Display (Std), LON Translator

D

2

Pass, MWB, 150 psig (1034 kPa), Flange, Suction Connections

 

N

Touch Pilot Display, EMM, LON Translator

F

2

Pass, MWB, 300 psig (2068 kPa), Flange, Discharge Connections

 

P

Touch Pilot Display, GFCI Service Option,

G

2

Pass, MWB, 300 psig (2068 kPa), Flange, Suction Connections

 

 

 

LON Translator

H

1

Pass, NIH, 150 psig (1034 kPa), Flange, Discharge Leaving

 

 

Q

Touch Pilot Display, EMM, GFCI Service

J

1

Pass, NIH, 300 psig (2068 kPa), Flange, Discharge Leaving

 

 

 

 

Option, LON Translator

K– 1 Pass, MWB, 150 psig (1034 kPa), Flange, Discharge Leaving

L– 1 Pass, MWB, 300 psig (2068 kPa), Flange, Discharge Leaving

 

 

 

 

Electrical Options

Heat Machine

-

Single Point, XL Starter, Terminal Block

0

 

(Std 380, 460, 575-v)

-

Std Condenser/Comfort Cooling (Std)

Single Point, Wye-Delta Starter, Terminal

M – Heat Machine Condenser/Comfort Cooling

3

Block (Std 200,230-v)

 

 

 

 

Dual Point, XL Starter, Terminal Block

 

 

 

 

4

Dual Point, Wye-Delta Starter, Terminal Block

Evaporator Options

7

Single Point, XL Starter, Non-Fused Disconnect

-

2 Pass, NIH, 150 psig (1034 kPa), Victaulic, Discharge Connections (Std)

8

Single Point, Wye-Delta, Non-Fused Disconnect

0

2 Pass, NIH, 150 psig (1034 kPa), Victaulic, Suction Connections

C

Dual Point, XL Starter, Non-Fused Disconnect

1

2 Pass, NIH, 150 psig (1034 kPa), Flange, Discharge Connections

D

Dual Point, Wye-Delta Starter, Non-Fused

2

2

Pass, NIH, 150 psig (1034 kPa), Flange, Suction Connections

H

Disconnect

3

2

Pass, NIH, 300 psig (2068 kPa), Victaulic, Discharge Connections

Single Point, XL Starter, Terminal Block, CPT

4

2

Pass, NIH, 300 psig (2068 kPa), Victaulic, Suction Connections

J

Single Point, Wye-Delta Starter, Terminal

5

2

Pass, NIH, 300 psig (2068 kPa), Flange, Discharge Connections

M

Block, CPT

6

2

Pass, NIH, 300 psig (2068 kPa), Flange, Suction Connections

Dual Point, XL Starter, Terminal Block, CPT

7

2

Pass, MWB, 150 psig (1034 kPa), Victaulic, Discharge Connections

N

Dual Point, Wye-Delta Starter, Terminal

8

2

Pass, MWB, 150 psig (1034 kPa), Victaulic, Suction Connections

R

Block, CPT

9

2

Pass, MWB, 300 psig (2068 kPa), Victaulic, Discharge Connections

Single Point, XL Starter, Non-Fused

B

2

Pass, MWB, 300 psig (2068 kPa), Victaulic, Suction Connections

S

Disconnect, CPT

C

2

Pass, MWB, 150 psig (1034 kPa), Flange, Discharge Connections

Single Point, Wye-Delta, Non-Fused

D

2

Pass, MWB, 150 psig (1034 kPa), Flange, Suction Connections

 

 

Disconnect, CPT

F

2

Pass, MWB, 300 psig (2068 kPa), Flange, Discharge Connections

W – Dual Point, XL Starter, Non-Fused

G

2

Pass, MWB, 300 psig (2068 kPa), Flange, Suction Connections

X

Disconnect, CPT

H

1

Pass, NIH, 150 psig (1034 kPa), Flange, Discharge Leaving

Dual Point, Wye-Delta Starter, Non-Fused

J

1

Pass, NIH, 300 psig (2068 kPa), Flange, Discharge Leaving

 

 

Disconnect, CPT

K– 1 Pass, MWB, 150 psig (1034 kPa), Flange, Discharge Leaving

L– 1 Pass, MWB, 300 psig (2068 kPa), Flange, Discharge Leaving

 

M – 3 Pass, NIH, 150 psig (1034 kPa), Flange, Discharge Leaving

Refrigeration Circuit Options*

 

N

3 Pass, NIH, 150 psig (1034 kPa), Flange, Suction Leaving

4

Standard Unit

 

P

3 Pass, NIH, 300 psig (2068 kPa), Flange, Discharge Leaving

6

With Suction Service Valves

 

Q – 3

Pass, NIH, 300 psig (2068 kPa), Flange, Suction Leaving

D – With Minimum Load Control

 

R – 3

Pass, MWB, 150 psig

(1034 kPa), Flange, Discharge Leaving

G – With Suction Service Valves and Minimum

 

S – 3

Pass, MWB, 150 psig

(1034 kPa), Flange, Suction Leaving

 

Load Control

 

T – 3

Pass, MWB, 300 psig

(2068 kPa), Flange, Discharge Leaving

N – With Condenser Insulation for Heat Machine

 

V – 3 Pass, MWB, 300 psig

(2068 kPa), Flange, Suction Leaving

Q – With Suction Service Valves and Condenser

 

 

 

 

 

 

 

 

Insulation for Heat Machine

 

 

 

LEGEND

 

 

X – With Minimum Load Control and Condenser

CPT

Control Power Transformer

 

MWB

Marine Waterbox

 

Insulation for Heat Machine

 

Z – With Suction Service Valves, Minimum Load

EMM

Energy Management Module

NIH

Nozzle-In-Head

 

Control and Condenser Insulation for

GFCI

Ground Fault Circuit Interrupter

XL

Across-the-Line Start

 

 

Heat Machine

LON — Local Operating Network

 

 

 

 

 

 

 

 

 

*Evaporator insulation is standard.

 

 

 

 

a30-4744

Quality Assurance

Certified to ISO 9001:2000

5

Image 5
Contents Small footprint Features/BenefitsTable of contents Refrigerant isolation valves Optional suction service valvesMarine container shipment Heat exchangersSmooth Rotary Compressor Touch Pilot DisplayTWIN-SCREW Design Optional Navigator DisplayA30-4744 Model number nomenclatureCapacity ratings 30XW325-400 Unit Physical Data English Physical data30XW325-400 Unit Physical Data SI Factory-installed options Options and accessoriesA30-4684.eps A30-4685Field-installed accessories Field-supplied and field-installed insulationA30-4686 FIELD-SUPPLIED and FIELD-INSTALLED Insulation30XW Unit Dimensions DimensionsStandard 30XW Unit Dimensions 30XW Unit and Waterbox Dimensions4755 A30A30-4747 A30-4748A30-4751 A30-4725A30-4749 A30-4752Evaporator and Condenser Flow Rates Selection procedurePerformance data 30XW325-400 Evaporator NIH Flange 30XW325-400 Evaporator Marine Waterbox30XW325-400 Condenser Marine Waterbox A30-469430XW325-400 Evaporator NIH Victaulic 30XW325-400 Condenser NIH Victaulic A30-469630XW325-400 Condenser NIH Flange Control sequence ControlsMicroprocessor Safeties A30-4697 Typical control wiring schematics30XW Unit Control Wiring Schematic Application data Variable evaporator flow rates Water loop volumeEvaporator fouling factor Condenser minimum flow rateElectric utility interests A30-4700 WiringTypical Piping and Wiring for 30XW Evaporator and Condenser Electrical data Standard Single Input Power ConfigurationSupply Optional Dual Input Power ConfigurationNO. Power ICF REC Fuse Control Circuit Unit 30HX Unit Voltage Compressor Compressor a Compressor B Size Compressor Electrical DataRLA LRA WD RLAHvac Guide Specifications Guide specificationsGuide specifications Page Carrier Corporation Syracuse, New York