Carrier 30XW325-400 manual Features/Benefits, Small footprint

Page 1

Product Data

AQUAFORCE® 30XW325-400 Water-Cooled Liquid Screw Chillers

325 to 400 Nominal Tons

(1133 to 1354 kW)

®

Carrier's AquaForce 30XW chillers provide a great combination of perfor- mance and compact footprint for cooling and heat recovery applica- tions. These chillers provide excellent reliability and efficiency at true operat- ing conditions without compromising the environment.

Chlorine-free R-134a HFC refrigerant

Positive displacement, twin screw compressors

AHRI (Air Conditioning, Heating, and Refrigeration Institute) certified efficiencies to 0.468 kW per ton IPLV (integrated part load value)

Dual independent refrigerant circuits

Compact footprint, less than 48 in. (1219 mm) wide

Easy to use controls

Features/Benefits

Quality design and construction make the AquaForce 30XW chillers an excellent choice for modern, efficient chilled water plants.

Small footprint

The 30XW chillers feature a compact footprint and are delivered as a single complete package less than 48 in.

(1219 mm) wide for easy installation and minimal indoor space. The 30XW chiller footprints may be up to 30% smaller when compared to other chill- ers and may require less mechanical room floor space and smaller concrete pads.

Copyright 2009 Carrier Corporation

Form 30XW-2PD

Image 1
Contents Small footprint Features/BenefitsTable of contents Refrigerant isolation valves Optional suction service valvesMarine container shipment Heat exchangersSmooth Rotary Compressor Touch Pilot DisplayTWIN-SCREW Design Optional Navigator DisplayA30-4744 Model number nomenclatureCapacity ratings 30XW325-400 Unit Physical Data English Physical data30XW325-400 Unit Physical Data SI Factory-installed options Options and accessoriesA30-4684.eps A30-4685Field-installed accessories Field-supplied and field-installed insulationA30-4686 FIELD-SUPPLIED and FIELD-INSTALLED Insulation30XW Unit Dimensions DimensionsStandard 30XW Unit Dimensions 30XW Unit and Waterbox Dimensions4755 A30A30-4747 A30-4748A30-4751 A30-4725A30-4749 A30-4752Performance data Selection procedureEvaporator and Condenser Flow Rates 30XW325-400 Evaporator NIH Flange 30XW325-400 Evaporator Marine Waterbox30XW325-400 Evaporator NIH Victaulic A30-469430XW325-400 Condenser Marine Waterbox 30XW325-400 Condenser NIH Flange A30-469630XW325-400 Condenser NIH Victaulic Microprocessor ControlsControl sequence Safeties 30XW Unit Control Wiring Schematic Typical control wiring schematicsA30-4697 Application data Variable evaporator flow rates Water loop volumeEvaporator fouling factor Condenser minimum flow rateElectric utility interests Typical Piping and Wiring for 30XW Evaporator and Condenser WiringA30-4700 Electrical data Standard Single Input Power ConfigurationNO. Power ICF REC Fuse Control Circuit Unit Optional Dual Input Power ConfigurationSupply 30HX Unit Voltage Compressor Compressor a Compressor B Size Compressor Electrical DataRLA LRA WD RLAHvac Guide Specifications Guide specificationsGuide specifications Page Carrier Corporation Syracuse, New York