Installation, cont’d

Control pass-through

The DVI DL 201 Tx/Rx cannot be controlled by RS-232 or IR controls. However, they are able to pass signals from a control device to a remote device that is controlled by those signals.

NThe RS-232 and IR communications are via a passive pass-through only; the transmitter and receiver neither generate nor respond to these signals.

Use the three-pole, 3.5 mm captive screw connector on the transmitter to input RS232 or IR signals from a control device. Use the corresponding connector on the receiver to pass signals to the output display.

Tx Rx

Tx Rx

3-Pole

Captive Screw

Connector

3/16" (5 mm)

MAX

CThe ideal length of exposed wire in the stripping process is 3/16" (5 mm). If longer than 3/16", the exposed wires may touch, causing a short circuit. If shorter than 3/16", the wires can be easily pulled out even if tightly fastened.

Do not tin the wires. Tinned wire does not hold its shape and comes loose over time.

2-18 DVI DL 201 Tx/Rx • Installation

Image 30
Contents DVI DL 201 Tx/Rx Dual Link DVI Transmitter and ReceiverPrecautions Safety Instructions English安全须知 中文 FCC Class a NoticePage Connect the display to the local monitor output Power on the source deviceQuick Start Guide -­ DVI DL 201 Tx/Rx Amber while the Edid information is readQuick Start Guide -­ DVI DL 201 Tx/Rx, cont’d To use DDC pass-through routed to the local monitorTable of Contents Table of Contents, cont’d One DVI DL 201 Tx/RxAbout this Manual DVI DL 201 Tx/Rx FeaturesIntroduction About the DVI DL 201 Tx/RxTypical Application for the DVI DL 201 Tx/Rx Extron DVI DL 201 TxIntroduction, cont’d Two Mounting the DVI DL 201 Tx/Rx InstallationTabletop placement Rack mountingRack mounting procedures Installing the DVI DL 201 Tx on a rack shelfInstallation, cont’d Under-desk mountingUnder-desk mounting the DVI DL 201 Tx Through-desk mounting Through-desk mounting the DVI DL 201 RxPole mounting Projector mounting the DVI DL 201 RxDVI DL 201 Tx/Rx Installation Installation, cont’d Panel Features DVI DL 201 Tx front panel featuresDVI DL 201 Tx front panel features DVI DL 201 Tx rear panel features DVI DL 201 TxDVI DL 201 Rx front panel features DVI DL 201 Rx front panel featuresDVI DL 201 Rx rear panel features DVI DL 201 Rx rear panel featuresInstallation, cont’d Cable Connections and Switches DVI-D inputDVI-D output Pin Signal Twisted pair output/input Terminating shielded cable Connections TIA/EIASingle Link/Dual Link DVI Video ResolutionSingle Link Mode Dual Link Mode 60 HzDDC switches Off positionControl pass-through Signal S, from the control device to RS-232 signalsIR signals Tx to Tx Rx to Rx Ground toPower input Connecting power to DVI DL 201 Tx/RxThree Configuration and Operation ConfigurationUsing the Edid Minder to read and store Edid from a display Connect the source device to the transmitter Input Using the Edid Minder with the default EdidSet the Edid Minder switch to the on up Connect the display device to the receiverConfiguration and Operation, cont’d Using pass-through mode with DDC routed to a local monitorPower on the display device Power on the local monitor, if required Configuration and Operation, cont’d Setup TroubleshootingDVI DL 201 Tx/Rx Configuration and Operation Configuration and Operation, cont’d AAppendix a Video SpecificationsReference Information Video input and loop-through transmitterVideo output receiver Control/remote external device pass-throughGeneral Warranty Years parts and labor Enclosure dimensionsDepth excludes connectors #60 ‑604 ‑20Accessory Part number Optional AccessoriesIncluded parts Replacement Part number Included PartsReference Information Extron’s Warranty USA, Canada, South America Japan Central AmericaExtron Electronics. All rights reserved