Extron electronic DVI DL 201 Rx Quick Start Guide -­ DVI DL 201 Tx/Rx, Power on the source device

Page 5
ON ON
i. j.

Quick Start Guide —­ DVI DL 201 Tx/Rx

The DVI DL 201 Tx/Rx extends DVI-D signals up to 100' (30 m) at resolutions up to 2560x1600 @ 60 Hz, using twisted pair (TP) cable. Install, connect, and operate the DVI DL 201 Tx/Rx as follows:

Step 1

Turn off all equipment or disconnect it from power sources. Mount the transmitter and receiver as desired (see page 2-2).

Step 2

Determine how the source device will obtain the EDID information and perform one of the following procedures:

To capture the EDID of a desired display and store it in the EDID Minder for future use:

a.

Connect the display to the local monitor output of

 

 

MINDEREDID

DEFAULTEDID

 

REMOTEDDC

 

the transmitter.

 

 

 

b.

Power on the transmitter and the local monitor.

ON

 

 

 

 

 

 

 

 

 

c.

Configure the DDC switches as shown in the figure

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

at right and described on page 3-2.

 

 

 

 

 

 

 

 

 

 

d.

Press and release the EDID "Store" button (see

OFF

 

1

 

2

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the figure at right). The rear panel LED turns

 

EDID

 

 

 

 

 

amber while the EDID information is read and

STORE

 

 

 

 

 

 

stored from the local monitor. Afterwards, the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED turns green.

 

 

 

 

 

 

 

 

 

 

e.

Power off and disconnect the display from the

 

 

 

 

 

 

 

 

 

 

 

transmitter.

 

 

 

 

 

 

 

 

 

 

f.

Connect the transmitter to the receiver.

 

 

 

 

 

 

 

 

 

 

g.

Connect a source device to the transmitter.

 

 

 

 

 

 

 

 

 

 

h.

Connect a display device to the receiver and, if required, a local

 

monitor to the transmitter.

 

 

 

 

 

 

 

 

 

 

 

Power on the display device(s), the transmitter, and the receiver.

Power on the source device.

To use the default EDID (2560x1600 @ 60 Hz):

a. Configure the DDC switches as shown in the figure at right and described on page 3-3.

b. Connect a source device to the transmitter. c. Connect a display device to the receiver and, if

required, a local monitor to the transmitter. OFF d. Connect the transmitter and receiver.

e. Power on the transmitter, receiver, and display devices.

EDID MINDER

DEFAULT EDID

REMOTE DDC

1

2

3

f. Power on the source device.

DVI DL 201 Tx/Rx • Quick Start Guide QS-1

Image 5
Contents Dual Link DVI Transmitter and Receiver DVI DL 201 Tx/RxSafety Instructions English PrecautionsFCC Class a Notice 安全须知 中文Page Quick Start Guide -­ DVI DL 201 Tx/Rx Power on the source deviceConnect the display to the local monitor output Amber while the Edid information is readTo use DDC pass-through routed to the local monitor Quick Start Guide -­ DVI DL 201 Tx/Rx, cont’dTable of Contents Table of Contents, cont’d DVI DL 201 Tx/Rx OneIntroduction DVI DL 201 Tx/Rx FeaturesAbout this Manual About the DVI DL 201 Tx/RxExtron DVI DL 201 Tx Typical Application for the DVI DL 201 Tx/RxIntroduction, cont’d Two Tabletop placement InstallationMounting the DVI DL 201 Tx/Rx Rack mountingInstalling the DVI DL 201 Tx on a rack shelf Rack mounting proceduresUnder-desk mounting the DVI DL 201 Tx Installation, cont’dUnder-desk mounting Through-desk mounting the DVI DL 201 Rx Through-desk mountingProjector mounting the DVI DL 201 Rx Pole mountingDVI DL 201 Tx/Rx Installation DVI DL 201 Tx front panel features Installation, cont’d Panel FeaturesDVI DL 201 Tx front panel features DVI DL 201 Tx DVI DL 201 Tx rear panel featuresDVI DL 201 Rx front panel features DVI DL 201 Rx front panel featuresDVI DL 201 Rx rear panel features DVI DL 201 Rx rear panel featuresDVI-D output Installation, cont’d Cable Connections and SwitchesDVI-D input Pin Signal Terminating shielded cable Twisted pair output/inputTIA/EIA ConnectionsSingle Link Mode Dual Link Mode Video ResolutionSingle Link/Dual Link DVI 60 HzOff position DDC switchesControl pass-through IR signals RS-232 signalsSignal S, from the control device to Tx to Tx Rx to Rx Ground toConnecting power to DVI DL 201 Tx/Rx Power inputThree Using the Edid Minder to read and store Edid from a display Configuration and OperationConfiguration Set the Edid Minder switch to the on up Using the Edid Minder with the default EdidConnect the source device to the transmitter Input Connect the display device to the receiverPower on the display device Configuration and Operation, cont’dUsing pass-through mode with DDC routed to a local monitor Power on the local monitor, if required Troubleshooting Configuration and Operation, cont’d SetupDVI DL 201 Tx/Rx Configuration and Operation Configuration and Operation, cont’d AAppendix a Reference Information SpecificationsVideo Video input and loop-through transmitterGeneral Video output receiverControl/remote external device pass-through Depth excludes connectors Enclosure dimensionsWarranty Years parts and labor #60 ‑604 ‑20Included parts Replacement Part number Optional AccessoriesAccessory Part number Included PartsReference Information USA, Canada, South America Japan Central America Extron’s WarrantyExtron Electronics. All rights reserved
Related manuals
Manual 2 pages 7.32 Kb

DVI DL 201 Tx, DVI DL 201 Rx specifications

Extron Electronics is renowned for its high-quality audio-visual solutions, and their DVI DL 201 TX/RX and DVI DL 201 RX are no exception. These devices are designed to facilitate digital video signal transmission over long distances, making them ideal for professional AV setups in educational institutions, corporate environments, and large venues.

The Extron DVI DL 201 TX (transmitter) and DVI DL 201 RX (receiver) feature advanced technology that supports DVI Dual Link video signals. This capability allows for the transmission of high-resolution video up to 2560x1600 at 60Hz, ensuring crisp and clear visuals essential for modern presentations and video playback.

One of the standout features of the DVI DL 201 series is its ability to extend DVI signals up to 200 feet (60 meters) using a single CAT 6 cable. This long-distance capability is particularly beneficial in expansive installations where traditional cabling may not suffice. The use of Exton’s advanced technology allows these devices to maintain signal integrity even at longer distances, mitigating concerns about video degradation.

The DVI DL 201 TX/RX is equipped with hot-plug detection, ensuring that both the transmitter and receiver can automatically recognize connected devices without the need for manual intervention. This enhances ease of use and simplifies the setup process for system integrators. Additionally, the devices are designed with a compact form factor, allowing for flexibility in installation without taking up excessive space.

Another notable characteristic of the DVI DL 201 series is its compatibility with a range of DVI sources and displays, making it a versatile solution in mixed technology environments. This flexibility, combined with their durability, makes these devices a reliable choice for any AV installation.

Furthermore, Extron incorporates thorough engineering in their products, ensuring that both the DVI DL 201 TX and RX meet high standards of performance and reliability. The devices are backed by Extron’s comprehensive support and warranty services, providing peace of mind for end-users.

In conclusion, the Extron DVI DL 201 TX/RX and DVI DL 201 RX introduce a robust solution for extending DVI signals, ensuring high-quality video transmission across considerable distances. With their advanced features and technologies, they are an excellent choice for any professional AV application.