Extron electronic DP DA2 manual Resetting Firmware to the Factory Default Version

Page 27
Resetting Firmware to the Factory Default Version

Figure 13. Firmware Loader Screen with a DP DA2 Added

12.If you want to remove a device from the Devices section, do the following:

a.Click on the names of the devices to be deleted, to highlight them.

b.Select Remove Selected Device(s) from the Edit menu.

c.On the Remove Device(s) window, select or deselect any devices on the list as desired, then click Remove.

To remove all devices, select Remove All Devices from the Edit menu.

13.Click Begin. The following indicators show the progress of the update:

The Transfer Time section shows the amounts of remaining and elapsed time for the update.

The Total Progress section displays a progress bar with Uploading... above it.

In the Devices section, the Progress column displays an incrementing percentage and another progress bar. The Status column displays Uploading.

14.The upload is complete when the Remaining Time field shows 00.00.00, the Progress column shows 100%, and Completed is displayed above the progress bar and in the Status column. Close the Firmware Loader window.

Resetting Firmware to the Factory Default Version

Occasionally the newly installed firmware may conflict with the system. If that occurs, it will be necessary to restore the original (factory-installed) firmware using the reset button, which is located in a recess on the base (see figure 14).

Use a small screwdriver to press the reset button for 10 seconds while powering on the DP DA2. The front panel power LED blinks amber three times, then lights solid amber, and finally blinks amber three more times while the reset occurs. When the reset is complete, the power LED lights solid green.

Reset Button

Figure 14. Firmware Reset Button on the Base of the DP DA2

DP DA2 • Updating Firmware

21

Image 27
Contents Distribution Amplifier DP DA2User Guide DisplayPortSicherheitsanweisungen Deutsch Safety InstructionsSafety Instructions English Instructions de sécurité FrançaisTrademarks Specifications AvailabilityFCC Class A Notice CopyrightSoftware Commands Conventions Used in this GuideNotifications Safety Instructions ContentsDP DA2 Contents About the DP DA2 DP DA2 Features DP DA2 FeaturesIntroduction About the DP DA2Application Diagram TouchLinkTCP/IP Panel Features Rear PanelFront Panel Power Supply Rear Panel FeaturesFunction Display Port ConnectorsRecording EDID Dual Mode DisplayPortEDID Minder EDID Store push button and LEDSummary DIP switchesDP DA2 Pin RS-232ControlMute Control Host PC PinConnecting to the USB Port Front Panel FeaturesPower LED Config USB PortDP DA2 Panel Features Figure 7. Installing the Software AutomaticallySignal and HDCP LEDs Signal LEDsHDCP LEDs Setup •Error Messages SIS CommandsIntroduction to SIS Introduction to SIS Symbols Used in this GuideSymbols Used in this Guide Error MessagesTable 1. ASCII to HEX Conversion Table Command and Response Table for SIS Commands Downloading DP DA2 Firmware Downloading and Installing Firmware LoaderUpdating Firmware Downloading and Installing Firmware LoaderFigure 9. Firmware Link on the Download Tab Downloading DP DA2 FirmwareFigure 10. Opening Firmware Loader Loading the Firmware to the DP DA2DP DA2 Updating Firmware DP DA2 Updating Firmware DP DA2 Updating Firmware Resetting Firmware to the Factory Default VersionDP DA2 Setup Guide Reference InformationIncluded Parts Optional PartsRack Mounting Desktop PlacementRack Mounting Procedure MountingExtron Warranty