Extron electronic DP DA2 manual Rear Panel Features, Power Supply

Page 10
Rear Panel Features

Rear Panel Features

Power Supply

The provided 12 VDC power supply connects to this 2-pole, 3.5 mm captive screw connector. The front panel power LED lights green when the unit is receiving power.

1.Connect the captive screw connector from the power supply to the power receptacle.

 

POWER

Rear Panel

12V

 

 

 

0.6 A MAX

Power Receptacle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Supply DC Power Cord

Captive Screw Connector

Manual background

+12 VDC

POWER 12V Manual backgroundManual backgroundManual background

0.6 A MAX

Smooth Manual backgroundManual background Ridges

A

A

SECTION A–A

Power Supply

Output Cord

3/16"

(5 mm) Max.

External

Power Supply

AC Power Cord (12 VDC, 1 A )

Figure 4. Power Connections

ATTENTION: Power supply voltage polarity is critical. Incorrect voltage polarity can damage the equipment. Identify the negative (or ground) lead by the ridges on the side of the cord (see the figure above).

Always use a power supply supplied by or specified by Extron. Use of an unauthorized power supply voids all regulatory compliance certification and may cause damage to the supply and the end product.

Unless otherwise stated, the AC to DC adapters are not suitable for use in air handling spaces or in wall cavities. The power supply is to be located within the same vicinity as the Extron AV processing equipment in an ordinary location, Pollution Degree 2, secured to the equipment rack within the dedicated closet, podium, or desk.

The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI/NFPA 70, article 75 and the Canadian Electrical Code part 1, section 16. The power supply shall not be permanently fixed to building structure or similar structure.

NOTES:

The ideal length of exposed wire in the stripping process is 3/16 inch (5 mm). If longer than 3/16 inch, the exposed wires may touch, causing a short circuit. If shorter than 3/16 inch, the wires can be easily pulled out even if tightly fastened.

Do not tin the wires. Tinned wire does not hold its shape and comes loose over time.

2.Connect the AC power cord of the power supply unit to a 110 or 220 VAC electrical source. When the unit is receiving power, the front panel LED shows a green light.

DP DA2 • Panel Features

4

Image 10
Contents DisplayPort DP DA2User Guide Distribution AmplifierInstructions de sécurité Français Safety InstructionsSafety Instructions English Sicherheitsanweisungen DeutschCopyright Specifications AvailabilityFCC Class A Notice TrademarksConventions Used in this Guide Software CommandsNotifications Contents Safety InstructionsDP DA2 Contents About the DP DA2 DP DA2 FeaturesIntroduction About the DP DA2 DP DA2 FeaturesTouchLink Application DiagramTCP/IP Rear Panel Panel FeaturesFront Panel Rear Panel Features Power SupplyDisplay Port Connectors FunctionEDID Store push button and LED Dual Mode DisplayPortEDID Minder Recording EDIDDIP switches SummaryHost PC Pin RS-232ControlMute Control DP DA2 PinConfig USB Port Front Panel FeaturesPower LED Connecting to the USB PortFigure 7. Installing the Software Automatically DP DA2 Panel FeaturesSignal LEDs Signal and HDCP LEDsHDCP LEDs Setup Introduction to SIS Symbols Used in this Guide SIS CommandsIntroduction to SIS •Error MessagesError Messages Symbols Used in this GuideTable 1. ASCII to HEX Conversion Table Command and Response Table for SIS Commands Downloading and Installing Firmware Loader Downloading and Installing Firmware LoaderUpdating Firmware Downloading DP DA2 FirmwareDownloading DP DA2 Firmware Figure 9. Firmware Link on the Download TabLoading the Firmware to the DP DA2 Figure 10. Opening Firmware LoaderDP DA2 Updating Firmware DP DA2 Updating Firmware Resetting Firmware to the Factory Default Version DP DA2 Updating FirmwareOptional Parts Reference InformationIncluded Parts DP DA2 Setup GuideMounting Desktop PlacementRack Mounting Procedure Rack MountingExtron Warranty