Emerson Hot1 manual Troubleshooting, Problem Possible Cause What to do

Page 12

Please read Troubleshooting Guide and/or visit www.insinkerator.com before calling AnswerLine

TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE

WHAT TO DO

Water and steam spits

• Unit is boiling.

• Depress faucet lever to release some water from

forcefully from spout

May be normal during initial setup.

the tank.

without turning on the

• Adjust water temperature using dial on tank front.

 

dispenser faucet.

 

 

Remember that at higher altitudes, water boils

 

 

 

 

at lower temperatures.

 

 

 

Water is not hot

• The unit is unplugged.

• Make sure the unit is connected to a properly grounded

 

• The electric outlet is inoperative.

electric outlet.

 

• Make sure the circuit breaker fuse is functioning properly.

 

 

 

 

• Check that the outlet is not switched off.

 

 

 

Water is too hot

• Thermostat is not adjusted to

• Adjust the thermostat slowly, then depress or twist faucet handle

or not hot enough

your needs.

for 20 seconds to bring in fresh water to be heated at the new

 

 

setting. Allow 5-7 minutes for water to reach new temperature.

 

 

 

Water is dripping from

• The expansion chamber isn’t draining

• Unplug the unit. If the dripping doesn’t stop after a few

the spout/vent

properly due to low water pressure.

minutes, check the supply valve to ensure that is fully

intermittently

• The spout is blocked.

open and there are no obstructions in the water line

 

reducing the pressure below 30 psi (i.e., a poorly mounted

 

 

 

 

saddle valve, a clogged water filter, or a partially opened

 

 

shut-off valve).

 

 

• Unscrew spout end piece and clean out any debris.

 

 

 

Water is dripping

• Debris in the water line may be

• Unscrew spout end piece and clean out any debris.

from the spout/vent

in the faucet valve seat causing a

• Depress lever 7-10 times to flush faucet & lines.

constantly

slow water leak.

 

Divided stream

• Debris in the end piece.

• Unscrew spout end piece and clean out any debris.

If you are still experiencing trouble call the AnswerLine1-800-558-5700.

12

Image 12
Contents Instant Hot Water Dispenser What YOU should Know Before YOU Begin Water will be cold since tank has not been plugged in yet Dimensions Preparation That operates your disposerRequired minimum from center of hole to wall Installing the Dispenser Remove the spout by looseningSet screw in spout holder Approximately 2 full turnsWater Connection Options Compression valve or T-fitting option not suppliedSaddle valve option not supplied Shutoff valve option not suppliedConnecting Water to Dispenser Nut FerruleFill the Tank & Connect Power First, open the shutoff valve allWatertight. If there are any leaks Carefully re-tighten all connectionsWarranty Information Year WarrantyDisconnect power From unit WarrantyCare and USE Troubleshooting Problem Possible Cause What to doManual del usuario Componentes EN Este Paquete Cómo Usar Este Manual DE Instrucciones Dimensiones Preparación Mismo interruptor de pared que opera su surtidorMuchos propietarios reemplazan el Instalación DEL Surtidor Quite el tubo surtidor de aguaPorta-tubo surtidor Aproximadamente 2 vueltasOpciones DE Conexión DE Agua Conecte el tubo de cobre deConexión DE Agua AL Surtidor En primer lugar, abra por completo La válvula de cierre y observe si susConexiones son herméticas. Si hay Alguna fuga, vuelva a apretar conInformación DE LA Garantía Garantía de un añoCuidado Y USO Desconecte la energía de la unidadLos limpiadores con ácidos, abrasivos Solución DE Problemas Problema Causa Posible QUÉ HacerManuel du propriétaire Composants Dans CE Paquet Comment Utiliser CE Manuel D’INSTRUCTIONS Dimensions Préparation Installation DU Distributeur Options DE Raccord D’EAU Option à valve de compression ou raccord en T non fournisOption à robinet-vanne non fourni Option à robinet de sectionnement non fourniRaccorder L’EAU AU Distributeur Ouvrez d’abord le robinet de Regardez si vos raccords sontÉtanches. S’il y a des fuites Resserrez avec soin tous lesInformation SUR LA Garantie Garantie d’un anEntretien ET Utilisation Pour ajuster laCoupez le courant à l’appareil Dépannage Problème Causes Possibles Quoi Faire

Hot1 specifications

The Emerson Hot1 is a cutting-edge thermal imaging solution that redefines the standards of temperature measurement in industrial applications. Tailored for maintenance teams and facility managers, it offers a comprehensive suite of features and technologies that enhance operational efficiency and safety.

One of the standout features of the Hot1 is its exceptional thermal sensitivity, which allows users to detect minor temperature variations. This sensitivity is critical for identifying potential problems in equipment before they escalate into costly failures. With a temperature measurement range of -20°C to 1200°C, the Hot1 is versatile enough to be used in various environments, from electrical inspections to mechanical systems.

The Emerson Hot1 incorporates advanced imaging technology, providing users with crisp, high-resolution thermal images. The integration of a robust, built-in camera enables users to capture both thermal and visual images simultaneously, allowing for detailed documentation and precise analysis. This dual-image capability is ideal for thorough reporting, ensuring that stakeholders are well-informed about the state of equipment.

One of the key technologies behind the Hot1 is its predictive maintenance capability. By continuously monitoring temperature data, the device enables users to implement a proactive maintenance strategy. This minimizes downtime and maximizes productivity by addressing issues before they become critical failures. Furthermore, the Hot1’s integrated data logging feature allows users to store and analyze historical temperature trends, offering insights into equipment performance over time.

User-friendly design is another hallmark of the Emerson Hot1. Its intuitive interface simplifies operation, making it accessible for both seasoned professionals and newcomers. The ergonomic design ensures comfort during extended use, and the lightweight construction enhances portability.

Additionally, the Hot1 is equipped with connectivity options, including Wi-Fi and Bluetooth, allowing for seamless integration with mobile devices and computers. Users can quickly upload images and data for remote analysis, further facilitating collaboration and decision-making.

In summary, the Emerson Hot1 thermal imaging device stands out for its combination of high sensitivity, advanced imaging technology, and predictive maintenance capabilities. Its user-centric design and connectivity options make it an invaluable tool for industries seeking to enhance their maintenance strategies, improve safety, and reduce operational costs. The Emerson Hot1 is a testament to innovation in thermal imaging, setting a new benchmark for reliability and performance.