Emerson Hot1 Installing the Dispenser, Remove the spout by loosening, Set screw in spout holder

Page 6

2

INSTALLING THE DISPENSER

A

■ Remove the spout by loosening

 

the set screw in spout holder

 

approximately 2 full turns and

 

pull out spout.

Mount the unit through the 1 3/8" diameter (35 mm) hole in the sink. Make sure the valve lever is in the up position and feed the spout end of the dispenser through the sink mounting hole.

B Mounting

Nut

Rubber

Gasket

The dispenser must be mounted in the upright (vertical) position only.

While holding the dispenser in place with spout removed, slip the rubber gasket and mounting nut over the valve lever and hand tighten the nut on the threaded barrel.

C

Wing

Nut

Spout and spout holder should not be loose after mounting. First tighten mounting nut and then tighten wing nut securely.

Align spout so water runs into the sink and secure the dispenser by tightening the wing nut from the underside of the sink.

D

Spout

Rubber

Seal

Personal Injury: Failure to tighten set screw allows easy removal of spout. Operation of unit with spout removed could cause injury from hot water spray.

Reassemble the spout ensuring the rubber seal is in place on inner spout tube grove before re-inserting spout into tank outlet.

If rubber seal is not on spout, check inside tank outlet. Remove and install seal per diagram.

Push spout into dispenser as far as it will go and tighten set screw.

6

Image 6
Contents Instant Hot Water Dispenser What YOU should Know Before YOU Begin Water will be cold since tank has not been plugged in yet Dimensions Preparation That operates your disposerRequired minimum from center of hole to wall Set screw in spout holder Installing the DispenserRemove the spout by loosening Approximately 2 full turnsSaddle valve option not supplied Water Connection OptionsCompression valve or T-fitting option not supplied Shutoff valve option not suppliedConnecting Water to Dispenser Nut FerruleWatertight. If there are any leaks Fill the Tank & Connect PowerFirst, open the shutoff valve all Carefully re-tighten all connectionsWarranty Information Year WarrantyDisconnect power From unit WarrantyCare and USE Troubleshooting Problem Possible Cause What to doManual del usuario Componentes EN Este Paquete Cómo Usar Este Manual DE Instrucciones Dimensiones Preparación Mismo interruptor de pared que opera su surtidorMuchos propietarios reemplazan el Porta-tubo surtidor Instalación DEL SurtidorQuite el tubo surtidor de agua Aproximadamente 2 vueltasOpciones DE Conexión DE Agua Conecte el tubo de cobre deConexión DE Agua AL Surtidor Conexiones son herméticas. Si hay En primer lugar, abra por completoLa válvula de cierre y observe si sus Alguna fuga, vuelva a apretar conInformación DE LA Garantía Garantía de un añoCuidado Y USO Desconecte la energía de la unidadLos limpiadores con ácidos, abrasivos Solución DE Problemas Problema Causa Posible QUÉ HacerManuel du propriétaire Composants Dans CE Paquet Comment Utiliser CE Manuel D’INSTRUCTIONS Dimensions Préparation Installation DU Distributeur Option à robinet-vanne non fourni Options DE Raccord D’EAUOption à valve de compression ou raccord en T non fournis Option à robinet de sectionnement non fourniRaccorder L’EAU AU Distributeur Étanches. S’il y a des fuites Ouvrez d’abord le robinet deRegardez si vos raccords sont Resserrez avec soin tous lesInformation SUR LA Garantie Garantie d’un anEntretien ET Utilisation Pour ajuster laCoupez le courant à l’appareil Dépannage Problème Causes Possibles Quoi Faire

Hot1 specifications

The Emerson Hot1 is a cutting-edge thermal imaging solution that redefines the standards of temperature measurement in industrial applications. Tailored for maintenance teams and facility managers, it offers a comprehensive suite of features and technologies that enhance operational efficiency and safety.

One of the standout features of the Hot1 is its exceptional thermal sensitivity, which allows users to detect minor temperature variations. This sensitivity is critical for identifying potential problems in equipment before they escalate into costly failures. With a temperature measurement range of -20°C to 1200°C, the Hot1 is versatile enough to be used in various environments, from electrical inspections to mechanical systems.

The Emerson Hot1 incorporates advanced imaging technology, providing users with crisp, high-resolution thermal images. The integration of a robust, built-in camera enables users to capture both thermal and visual images simultaneously, allowing for detailed documentation and precise analysis. This dual-image capability is ideal for thorough reporting, ensuring that stakeholders are well-informed about the state of equipment.

One of the key technologies behind the Hot1 is its predictive maintenance capability. By continuously monitoring temperature data, the device enables users to implement a proactive maintenance strategy. This minimizes downtime and maximizes productivity by addressing issues before they become critical failures. Furthermore, the Hot1’s integrated data logging feature allows users to store and analyze historical temperature trends, offering insights into equipment performance over time.

User-friendly design is another hallmark of the Emerson Hot1. Its intuitive interface simplifies operation, making it accessible for both seasoned professionals and newcomers. The ergonomic design ensures comfort during extended use, and the lightweight construction enhances portability.

Additionally, the Hot1 is equipped with connectivity options, including Wi-Fi and Bluetooth, allowing for seamless integration with mobile devices and computers. Users can quickly upload images and data for remote analysis, further facilitating collaboration and decision-making.

In summary, the Emerson Hot1 thermal imaging device stands out for its combination of high sensitivity, advanced imaging technology, and predictive maintenance capabilities. Its user-centric design and connectivity options make it an invaluable tool for industries seeking to enhance their maintenance strategies, improve safety, and reduce operational costs. The Emerson Hot1 is a testament to innovation in thermal imaging, setting a new benchmark for reliability and performance.