Haier BD-478A service manual Test method and instrument, Temperature with load

Page 52

temperature with load.

Type tests include items (1), (2), (8), (9), (10), (13), (17), (18), (20), (21) and the followings: (22) total effective volume; (23) ice producing ability; (24) frost melting performance; (25) heat insulation performance and anti dew;

(26)gas tightness of door seal; (27) duration of door bar and handle; (28) strength of supporting bracket and similar parts; (29) internal freezer material and smell; (30) firmness of freezer and transportation test.

12.8.2 Test method and instrument

12.8.2.1 Sealing performance test of refrigeration system

In this test, freezer is put to positive pressure room, temperature is 16-32. Leakage inspection instrument is set to 0.5g of yearly leakage, check every position of refrigeration system. Leakage at any point shall not greater than 0.5g. Leakage inspection instrument normally used includes H-25 of American GE product and Halogen instrument HLD4000 made by a German company.

12.8.2.2 Insulation resistor

This test is to check the insulation performance of freezer. The resistance is measured with a voltage of 500V DC added to live parts and accessible metal parts. The resistance must be not less than 2 million ohm.

MAINTENANCE SERVICE AND TROUBLE SHOOTING

Maintenance Service and Trouble Shooting

12.8.2.3 Electrical intensity

This test is to check the electrical intensity of live parts and all accessible metal parts. The testing equipment is flashover and breakdown unit,

51

PDF created with pdfFactory trial version www.pdffactory.com

Image 52
Contents BD-478A Contents Product Code Illumination and Series Introduction First letter of Freezer in Chinese spellingFeatures FeaturesSpecifications BD-388A BD-478ASafety Precautions Safety Precautions 1420*715*810 1690*715*810 Net Dimension1420*715*1470 1690*715*1470 Installation and Accessory Parts ·Proper Air CirculationElectrical Requirement Installation and Accessory Parts Defrosting and Draining The Freezer Food Storage BasketSystem Flow Chart Adjustable temperature dial Function ScheduleMaintenance Service and Trouble Shooting Brief description of principle about BD-318A/428AServicing freezer Reasons of electricity leakage of freezerMaintenance Service and Trouble Shooting Maintenance Service and Trouble Shooting Troubleshooting by sounds Troubleshooting by touch System noise repair Poor freezing effect analysis and solutions How to handle the seal bar for poor sealing Why freezer cannot be used at low temperature environment How to know there is problem with compressor MotorPage Page Procedure for fan change Procedure for temperature controller changeCommon freezer problems Operation of freezer is not normal Repair equipment Requirements Service procedureEvacuation and fill machine is special only for R134a use Changing procedure of R134a compressor Compressor installation and brazing procedures Application and maintenance of freezer Product charactersPage Safety notice of product MaintenanceStandard procedure of maintenance 12.5 Freezer repair tool and equipment It is not allowed to fill R134a by R12 filling equipmentProcedure for filling equipment ⑧ Switch off motorCompressor Freezer noise sourcesFilling Resonance sound of compressor components How is the sound of water flowing generated? Gas flowing soundWhy the freezer’s noise increases after using Why freezer’s noise increases after stop use for sometime? How to reduce freezer’s noise?Why freezer noise changes greater at night? Sometime?Why freezer noise measured at home is incorrect? What are the national stipulations for freezer Noise?Page Why the noises of it type freezers are different? AnswerHow to determine that the sound is noise or Normal? Noise test There are stipulations in Items 6.5.7.1 and 6.3.6.1.of GB/TMaintenance Service and Trouble Shooting 12.8Measuring technology of freezer performance parameter Temperature with load Test method and instrumentGround resistor Maintenance Service and Trouble Shooting Maintenance Service and Trouble Shooting Maintenance Service and Trouble Shooting Exploded View List of Parts QTY BD-388A/478A 392% 600% Lamp switch BD-388A/478A 010% 020%