voltage is 1650V (50Hz) for 2s. At the test, there will not flashover and breakdown occurring.

12.8.2.4 Ground resistor

Check the voltage drop between freezer ground connection point and accessible metal parts, using AC power of load empty voltage not over 12V and 10A current. Calculate the resistance according to the current and voltage drop. Ground connection resistance shall not exceed 0.1 ohm.

12.8.2.5 Leakage of current

When testing, give 1.06 times rated voltage to the freezer, and make the test at operation status. The test complies with GB4706.1-84, the leakage

current testing instrument is made in accordance with the stipulations. The leakage current measured shall not exceed 1.5mA.

12.8.2.6 Noise test

This test is carried out at semi sound eliminating room. The freezer is put to the geometrical center of room, on a 5-10mm thick elastic cushion. The freezer should be empty when testing. Turn the knob of temperature controller to middle or near to strong position and close the door. Test after

the freezer has running more than 30 minutes. The freezer noise power level, 250L and below, ≤52dB(A); 250L above ≤55dB(A)

MAINTENANCE SERVICE AND TROUBLE SHOOTING

Maintenance Service and Trouble Shooting

12.8.2.7 Test method of refrigeration performance

(1) 4 or 6 freezers can be tested simultaneously at the test room. The

52

PDF created with pdfFactory trial version www.pdffactory.com

Image 53
Contents BD-478A Contents First letter of Freezer in Chinese spelling Product Code Illumination and Series IntroductionFeatures FeaturesBD-388A BD-478A SpecificationsSafety Precautions Safety Precautions 1420*715*1470 1690*715*1470 Net Dimension1420*715*810 1690*715*810 ·Proper Air Circulation Installation and Accessory PartsElectrical Requirement Installation and Accessory Parts Food Storage Basket Defrosting and Draining The FreezerSystem Flow Chart Function Schedule Adjustable temperature dialBrief description of principle about BD-318A/428A Maintenance Service and Trouble ShootingReasons of electricity leakage of freezer Servicing freezerMaintenance Service and Trouble Shooting Maintenance Service and Trouble Shooting Troubleshooting by sounds Troubleshooting by touch System noise repair Poor freezing effect analysis and solutions How to handle the seal bar for poor sealing How to know there is problem with compressor Motor Why freezer cannot be used at low temperature environmentPage Page Procedure for temperature controller change Procedure for fan changeCommon freezer problems Operation of freezer is not normal Evacuation and fill machine is special only for R134a use Service procedureRepair equipment Requirements Changing procedure of R134a compressor Compressor installation and brazing procedures Product characters Application and maintenance of freezerPage Maintenance Safety notice of productStandard procedure of maintenance 12.5 It is not allowed to fill R134a by R12 filling equipment Freezer repair tool and equipment⑧ Switch off motor Procedure for filling equipmentFilling Freezer noise sourcesCompressor Resonance sound of compressor components Gas flowing sound How is the sound of water flowing generated?Why the freezer’s noise increases after using How to reduce freezer’s noise? Why freezer’s noise increases after stop use for sometime?Why freezer noise changes greater at night? Sometime?What are the national stipulations for freezer Noise? Why freezer noise measured at home is incorrect?Page Answer Why the noises of it type freezers are different?How to determine that the sound is noise or Normal? There are stipulations in Items 6.5.7.1 and 6.3.6.1.of GB/T Noise testMaintenance Service and Trouble Shooting 12.8Measuring technology of freezer performance parameter Test method and instrument Temperature with loadGround resistor Maintenance Service and Trouble Shooting Maintenance Service and Trouble Shooting Maintenance Service and Trouble Shooting Exploded View List of Parts QTY BD-388A/478A 392% 600% Lamp switch BD-388A/478A 010% 020%