Extron electronic manual QGE 100 List section

Page 27

QGE 100 List section

The QGE 100 List section displays information on all QGEs detected by the Administrator software at startup. The figure below shows an example of a QGE 100 List section in which two QGEs are displayed: one connected in multicast mode and one in unicast mode.

QGEs that appear grayed-out on this list are not connected; they are showing details from the last time they were connected. Click Refresh to update the connection.

Figure 14. QGE 100 List Example

TIP: You can adjust the width of each column of the QGE 100 List by dragging the

vertical bars between the column headings. You can also change the order of the columns by dragging column headings to the desired locations.

The following parameters are displayed for each detected QGE 100:

Parameter

Description

 

 

 

 

QGE 100

Name of the QGE 100 (if assigned)

 

 

IP Address

IP address of the QGE

Type

This field always displays Hardware.

 

 

TCP Connection

(Unicast mode only) IP address of the viewing device. If multicast

 

mode is being used, this field displays No.

 

 

Max FR

The frame rate limit that is currently set

Max BW

The bandwidth rate limit that is currently set

 

 

Version

Firmware version of the QGE

 

 

Protocol

Current operating mode (TCP Unicast or UDP Multicast)

Multicast Group

(Multicast mode only) The multicast IP address that is currently set

 

 

Multicast Errors

(Multicast mode only) When logging is enabled, the number

 

of multicast errors (if any) reported by the QGE. Two values are

 

displayed:

 

Recent=n (n = errors reported since the last check.)

 

Total=n (n = all errors reported since logging began.)

 

To set up error logging, see “Multicast Error Logging” on

 

page 44.

 

 

Status

The status of the source. This can be one of the following:

 

Ready (The unit is functioning normally.)

 

Waiting for Apply (Settings have been changed but have not

 

been applied.)

 

Committing (New settings are being saved to flash memory.)

 

Rebooting (The source is restarting to implement new settings.)

 

 

QGE 100 • Software Configuration and Control

21

Image 27
Contents QGE Safety Instructions English FCC Class a Notice Software Commands Conventions Used in this GuideNotifications Contents QGE 100 Contents About the QGE 100 Encoder About this GuideSingle or Multiple Users QGE 100 SoftwareQGE 100 Data Stream FeaturesFunctional Overview Image Capture and DistributionOperating System Managing the NetworkEdid Management QGE 100 connected with a local monitorQGE 100 connected with no local monitor Digital and Analog Representation Supported Source FormatsMulticast Streaming Application DiagramsInstallation Overview Installation OperationQGE 100 Rear Panel Rear Panel FeaturesPin Function Connecting the Source Computer to the QGEFor an analog source computer Analog Monitor Cable with FerriteConnection Procedure Connecting the QGE 100 to the NetworkEthernet Connection Indicators Connecting Power to the UnitIf mounting the QGE 100 on a rack Connection DiagramsConnections with a Digital Source Digital Source Connection DiagramConnections with an Analog Source Analog Connection DiagramQGE 100 Front Panel Front Panel FeaturesComputer System Requirements Accessing the Software ProgramsUsing the QGE 100 Administrator Program Installing the SoftwareStarting the Administrator Program Tasks section QGE 100 Administrator Main Application WindowQGE 100 List section Recent connections Configure QGE 100 Properties sectionMenu bar Option DescriptionTools menu Other QGE 100 window itemsViewing a QGE 100 Source Administrator Viewer windowMenu Option Toolbar Icon Description Administrator Viewer menu OptionsAdding QGEs to the list Managing the QGE 100 ListRefreshing the list Saving the listDeleting a QGE from the list Deleting the QGE 100 ListLoading a saved QGE 100 List Changing the Password Logging In and Out Administrator LevelConfiguring a QGE Configuring performance settingsConfiguring network settings Setting Description Network Settings WindowNetwork Settings Section for UDP Multicast Configuration Configuring UDP multicast settingsDetect Quantum Sources Window Configuring the QGE for Use with a Quantum Elite ProcessorQGE 100 Software Configuration and Control Starting the Viewer Program Using the QGE 100 Viewer ProgramPort QGE 100 Viewer WindowConnections Menus and toolbarOption Toolbar Icon Description RecentView menu Connecting using the Channel list Connecting to a QGE 100 SourceRefreshing the Channel List Connecting using the Connect dialog boxConnecting to a QGE 100 on another subnet Disconnecting from a QGELearning Dialog Example Learning DialogsConfiguring keyboard and mouse control options Mouse and Keyboard Control of the Source ComputerEnabling Mouse and Keyboard Control From the Special Context menu Field To enter a valueTo end the current control session, do any of the following Starting and stopping a mouse and keyboard control sessionUsing the Special Context menu Multicast Error LoggingSync SpecificationsVideo input Video processingIP, TCP, UDP, Dhcp GeneralAccessories Part Number Part Numbers and AccessoriesOptional Accessories Included Parts Replacement Part NumberOther Rack Mounting Requirements Power supplyMounting the QGE 100 Encoder UL Guidelines for Rack MountingClass Name Valid Address Range Identifier Arrangement What is an IP Address?IP Addressing Choosing IP AddressesClass Name Subnet Mask Subnet MaskPinging for the IP Address Ping to determine the Extron IP addressLocal and remote devices Subnetting, a PrimerPinging to determine the web IP address GatewaysUnmasked octets are compared indicated by ? in figure IP addresses and octetsSubnet masks and octets Determining whether devices are on the same subnetData stream bottlenecks Troubleshooting PerformancePerformance Criteria Things that Impact Performance CriteriaSource scaling Optimizing the Encoder Parameters Europe USA, Canada, South America Japan Central AmericaEurope, Africa, and the Middle China East Asia Middle East
Related manuals
Manual 4 pages 54.09 Kb

QGE 100 specifications

The Extron QGE 100 is a high-performance network switch engineered specifically for AV system integration. With its advanced capabilities, this device plays a crucial role in managing AV data traffic, ensuring reliable performance and efficiency in various settings such as corporate environments, educational institutions, and healthcare facilities.

One of the key features of the QGE 100 is its support for Power over Ethernet (PoE). This allows the switch to deliver both data and power to connected devices over a single Ethernet cable, simplifying installations and reducing the need for additional power sources. This is particularly beneficial for devices like IP cameras, wireless access points, and AV devices in scenarios where accessibility to power outlets may be limited.

The QGE 100 also provides a robust Layer 2 switching functionality, which is essential for managing data flow within the network. Its capability to handle multiple VLANs ensures that AV traffic can be segregated effectively, thus improving network performance and security. The switch features IGMP Snooping, a protocol that optimizes multicast traffic management, ensuring that video streams reach the intended recipients without unnecessary bandwidth consumption.

In terms of connectivity, the Extron QGE 100 is equipped with multiple Gigabit Ethernet ports, facilitating high-speed data transmission for AV content. The switch's user-friendly management interface allows for straightforward configuration, monitoring, and troubleshooting, streamlining operations across AV environments. Additionally, it supports link aggregation, enhancing bandwidth and redundancy when connecting multiple devices.

The QGE 100 is also designed with reliability in mind, featuring a fanless operation that minimizes noise and ensures a long lifespan. Its compact form factor allows for easy rack mounting in equipment racks, maintaining a clean and organized setup.

Another vital characteristic of the QGE 100 is its compatibility with Extron's comprehensive suite of AV control and management products. This integration capability provides users with a cohesive solution for managing their AV systems, further enhancing the overall user experience.

In conclusion, the Extron QGE 100 network switch is an essential tool for any AV system requiring efficient connectivity, power delivery, and data management. Its sophisticated features and technologies make it a valuable asset in modern AV installations, ensuring robust performance and ease of use.