Extron electronic QGE 100 manual Multicast Error Logging, Using the Special Context menu

Page 50

Using the Special Context menu

The Special Context pop-up menu contains commands that you can select to send to the source computer during a mouse and keyboard control session. (You can display this menu only during a control session.)

Figure 32. Special Context Pop-up Menu

To use the Special Context menu:

1.Press the key combination specified on the Mouse & Keyboard Options window (by default, this is <Ctrl> + <F2>). The Special Context menu pops up and a mouse pointer appears on the Viewer window.

2.Move the mouse pointer to the desired menu option and click the command to issue it to the source computer, or click End Keyboard And Mouse to end the control session.

To close the Special Context menu, press <Esc> on your viewing computer keyboard.

Multicast Error Logging

Using either the QGE 100 Viewer or Administrator, you can set up the QGE to log error conditions that occur while the encoder is operating in multicast mode. When logging is enabled, the number of recent errors (since last check) and total errors (since logging began) are recorded in the Multicast Errors column of the QGE 100 List on the Administrator main window. This log can be used for trouble-shooting.

To set up error logging via either software program:

1.From the Tools menu, select Logging. The Logging Options window opens.

Figure 33. Logging Options Window

2.Select the Enable Multicast Error Logging check box.

3.In the Logging Interval field, enter the number of seconds (1 through 9) that will elapse between log entries. (The default is 9.)

4.Click OK.

QGE 100 • Software Configuration and Control

44

Image 50
Contents QGE Safety Instructions English FCC Class a Notice Notifications Software CommandsConventions Used in this Guide Contents QGE 100 Contents About this Guide About the QGE 100 EncoderQGE 100 Software Single or Multiple UsersImage Capture and Distribution FeaturesFunctional Overview QGE 100 Data StreamManaging the Network Operating SystemQGE 100 connected with no local monitor Edid ManagementQGE 100 connected with a local monitor Supported Source Formats Digital and Analog RepresentationApplication Diagrams Multicast StreamingInstallation Operation Installation OverviewRear Panel Features QGE 100 Rear PanelConnecting the Source Computer to the QGE Pin FunctionAnalog Monitor Cable with Ferrite For an analog source computerConnecting the QGE 100 to the Network Connection ProcedureConnecting Power to the Unit Ethernet Connection IndicatorsConnection Diagrams If mounting the QGE 100 on a rackDigital Source Connection Diagram Connections with a Digital SourceAnalog Connection Diagram Connections with an Analog SourceFront Panel Features QGE 100 Front PanelAccessing the Software Programs Computer System RequirementsStarting the Administrator Program Using the QGE 100 Administrator ProgramInstalling the Software QGE 100 Administrator Main Application Window Tasks sectionQGE 100 List section Option Description Configure QGE 100 Properties sectionMenu bar Recent connectionsOther QGE 100 window items Tools menuAdministrator Viewer window Viewing a QGE 100 SourceAdministrator Viewer menu Options Menu Option Toolbar Icon DescriptionSaving the list Managing the QGE 100 ListRefreshing the list Adding QGEs to the listLoading a saved QGE 100 List Deleting a QGE from the listDeleting the QGE 100 List Logging In and Out Administrator Level Changing the PasswordConfiguring network settings Configuring a QGEConfiguring performance settings Network Settings Window Setting DescriptionConfiguring UDP multicast settings Network Settings Section for UDP Multicast ConfigurationConfiguring the QGE for Use with a Quantum Elite Processor Detect Quantum Sources WindowQGE 100 Software Configuration and Control Using the QGE 100 Viewer Program Starting the Viewer ProgramQGE 100 Viewer Window PortRecent Menus and toolbarOption Toolbar Icon Description ConnectionsView menu Connecting to a QGE 100 Source Connecting using the Channel listDisconnecting from a QGE Connecting using the Connect dialog boxConnecting to a QGE 100 on another subnet Refreshing the Channel ListLearning Dialogs Learning Dialog ExampleEnabling Mouse and Keyboard Control Configuring keyboard and mouse control optionsMouse and Keyboard Control of the Source Computer Field To enter a value From the Special Context menuStarting and stopping a mouse and keyboard control session To end the current control session, do any of the followingMulticast Error Logging Using the Special Context menuVideo processing SpecificationsVideo input SyncGeneral IP, TCP, UDP, DhcpIncluded Parts Replacement Part Number Part Numbers and AccessoriesOptional Accessories Accessories Part NumberUL Guidelines for Rack Mounting Power supplyMounting the QGE 100 Encoder Other Rack Mounting RequirementsChoosing IP Addresses What is an IP Address?IP Addressing Class Name Valid Address Range Identifier ArrangementPing to determine the Extron IP address Subnet MaskPinging for the IP Address Class Name Subnet MaskGateways Subnetting, a PrimerPinging to determine the web IP address Local and remote devicesDetermining whether devices are on the same subnet IP addresses and octetsSubnet masks and octets Unmasked octets are compared indicated by ? in figureThings that Impact Performance Criteria Troubleshooting PerformancePerformance Criteria Data stream bottlenecksSource scaling Optimizing the Encoder Parameters Asia Middle East USA, Canada, South America Japan Central AmericaEurope, Africa, and the Middle China East Europe
Related manuals
Manual 4 pages 54.09 Kb

QGE 100 specifications

The Extron QGE 100 is a high-performance network switch engineered specifically for AV system integration. With its advanced capabilities, this device plays a crucial role in managing AV data traffic, ensuring reliable performance and efficiency in various settings such as corporate environments, educational institutions, and healthcare facilities.

One of the key features of the QGE 100 is its support for Power over Ethernet (PoE). This allows the switch to deliver both data and power to connected devices over a single Ethernet cable, simplifying installations and reducing the need for additional power sources. This is particularly beneficial for devices like IP cameras, wireless access points, and AV devices in scenarios where accessibility to power outlets may be limited.

The QGE 100 also provides a robust Layer 2 switching functionality, which is essential for managing data flow within the network. Its capability to handle multiple VLANs ensures that AV traffic can be segregated effectively, thus improving network performance and security. The switch features IGMP Snooping, a protocol that optimizes multicast traffic management, ensuring that video streams reach the intended recipients without unnecessary bandwidth consumption.

In terms of connectivity, the Extron QGE 100 is equipped with multiple Gigabit Ethernet ports, facilitating high-speed data transmission for AV content. The switch's user-friendly management interface allows for straightforward configuration, monitoring, and troubleshooting, streamlining operations across AV environments. Additionally, it supports link aggregation, enhancing bandwidth and redundancy when connecting multiple devices.

The QGE 100 is also designed with reliability in mind, featuring a fanless operation that minimizes noise and ensures a long lifespan. Its compact form factor allows for easy rack mounting in equipment racks, maintaining a clean and organized setup.

Another vital characteristic of the QGE 100 is its compatibility with Extron's comprehensive suite of AV control and management products. This integration capability provides users with a cohesive solution for managing their AV systems, further enhancing the overall user experience.

In conclusion, the Extron QGE 100 network switch is an essential tool for any AV system requiring efficient connectivity, power delivery, and data management. Its sophisticated features and technologies make it a valuable asset in modern AV installations, ensuring robust performance and ease of use.