2-5. THERMAL SENSOR
REPLACEMENT |
|
|
| 1. | Remove electrical power to unit. |
|
| To avoid electrical shock or property damage, move the |
|
| power switch to OFF and disconnect main circuit |
|
| breaker, or unplug cord at wall receptacle. |
| 2. | Remove the side panel closest to the controls. |
Step 2 | 3. | Unplug probe from control PC board. |
| ||
| 4. | Press down on the probe bracket and pull probe from |
|
| bracket, or using 3/8" socket, remove nut securing probe |
|
| bracket to unit and remove bracket and probe from unit. |
| 5. | Remove vent panels from inside unit. (See Cleaning |
|
| Section of Operator’s Manual.) |
Step 3 | 6. | Install new probe in reverse manner, exposing the probe |
|
| 1½” (38 mm) inside cabinet. |
1½ inch (38 mm) probe position is important. Improper positioning causes erroneous temperature readings.
7.Plug probe onto P2, a 2 pin connector.
Step 6