Henny Penny 290 manual Power Section, Heating of Shortening Section

Page 6

Model 290

Problem

Cause

Correction

POWER SECTION

With switch in POWER position, the fryer is com- pletely inoperative (NO POWER)

Open circuit

Check to see that unit is plugged in

Check the breaker or fuse at supply box

Check voltage at wall receptacle

Check MAIN POWER switch; replace if defective

Check cord and plug

Check 15 amp fuses

HEATING OF SHORTENING SECTION

Shortening will not heat

Blown fuse or tripped

Reset breaker or replace fuse

 

 

 

circuit breaker at supply

 

 

 

box or control panel

 

Blown fuse in PC board

Replace glass fuse in board

 

Faulty POWER/PUMP switch.

Check POWER/PUMP switch

 

 

 

per maintenance section on

 

 

 

the POWER/PUMP switch

 

Faulty cord and plug

Check cord and plug

 

 

• Check power at receptacle

 

Faulty drain switch

Check drain switch per

 

 

 

maintenance section on

 

 

 

drain switches

 

Faulty PC Board

Remove and replace control

 

 

 

panel

 

Faulty high limit control switch

Check high limit control

 

 

 

switch per maintenance

 

 

 

section on the high limit

 

Drain valve open

Close drain valve

 

Possible faulty temperature probe

Replace temperature probe

 

Faulty contactor

Check contactor per maintenance

 

 

 

section on contactors

 

 

 

 

1203

1-6

Image 6 Contents
Introduction TroubleshootingSafety Hazardous Situation WHICH, if not To isolate a malfunction, proceed as follows Cooking Section Problem Cause Correction Cooking Section 103 Power Section Heating of Shortening SectionProblem Cause Correction Heating of Shortening Section Shortening FOAMING/DRAINING Section Error Codes Display Cause Panel Board CorrectionDisplay Cause Panel Board Correction