2. Water-Cooled Condenser
a) Connection to an Open Drain System
•Condenser water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" OD copper tubing is recommended for the condenser water supply line.
•A condenser water supply line
•Condenser drain outlet is 3/8" FPT. A minimum of 3/8" OD hard pipe is recommended for the condenser drain line.
•In some areas, a back flow preventer may be required in the condenser water supply line.
Storage Bin
Drain Outlet
3/4" FPT
Drip Tray
Drain Outlet
3/4" FPT
Icemaker
Stand
Vent
Tube
Icemaker Water |
|
Supply Inlet |
|
1/2" FPT | Icemaker Water Supply |
| |
Condenser | Line |
| |
Drain Outlet |
|
3/8" FPT |
|
| Icemaker Water Supply |
| Line Drain Valve |
Vent |
|
Tube | Condenser Water Supply |
| Line |
| Condenser Water |
| Supply Line Drain Valve |
Condenser Water Supply Inlet 1/2" FPT
Separate piping to approved drain. Leave a
Fig. 5
Floor Drain
DCM-750BWH(-OS)
Connection to an Open Drain System
20