Hoshizaki DCM-750BWH(-OS), DCM-750BAH(-OS) F. Water Supply and Drain Connections, See , 5, or

Page 18
F. Water Supply and Drain Connections

F. Water Supply and Drain Connections

See Fig. 4, 5, or 6

See Fig. 4, 5, or 6WARNING

1.Water supply and drain connections must be installed in accordance with applicable national, state, and local regulations.

2.Normal operating water temperature should be within 45°F to 90°F (7°C to 32°C). Operation of the icemaker, for extended periods, outside of this normal temperature range may affect icemaker performance.

3.To prevent damage to equipment, do not operate the icemaker when the water supply is off, or if the pressure is below 10 PSIG. Do not run the icemaker until the proper water pressure is reached.

A plumbing permit and services of a licensed plumber may be required in some areas.

External filters, strainers, or softeners may be required depending on water quality. Contact your local Hoshizaki distributor for recommendations.

Water supply pressure should be a minimum of 10 PSIG and a maximum of 113 PSIG. If the pressure exceeds 113 PSIG, the use of a pressure reducing valve is required.

The storage bin drain line, drip tray drain line, and water‑cooled condenser drain line (if applicable) must be run separately.

Drain lines must have 1/4" fall per foot (2 cm per 1 m) on horizontal runs to get a good flow. A vented tee connection is also required for proper flow.

Drain lines should not be piped directly to the sewer system. An air gap of a minimum of 2 vertical inches (5 cm) should be between the end of the drain pipes from the storage bin, drip tray, and water-cooled condenser (if applicable) and the floor drain.

18

Image 18
Contents Cubelet Icemaker / Dispenser Models DCM-750BAH-OS DCM-750BWH-OS INSTRUCTION MANUALHoshizakiHoshizaki America, Inc Peachtree City, GA •Complete and detailed explanation of the problemHOSHIZAKI AMERICA, INC 618 Highway 74 South Attn: Hoshizaki Technical Support DepartmentCONTENTS Important Safety Information I. Specifications A. Nameplate Rating HOSHIZAKI ICE MAKERHoshizaki America, Inc 2. DCM-750BAH-OS air-cooled 3. DCM-750BWH water-cooled 4. DCM-750BWH-OS water-cooled B. Dimensions/Connections 1. DCM-750BAH2. DCM-750BAH-OS 3. DCM-750BWH 4. DCM-750BWH-OS SD-700 SD-700 80-11/162050 SD-750 80-15/162057SD-700 26-1/2673 SD-750 26-3/4680 SD-750II. Installation and Operating Instructions A.Checks Before InstallationDCM-750B_H B. How to Remove PanelsFig. DCM-750B_H-OSD.Setup C. LocationE. Electrical Connection ELECTRICAL CONNECTIONF. Water Supply and Drain Connections See Fig. 4, 5, orDCM-750BAH-OS 1. IcemakerDCM-750BWH-OS Connection to an Open Drain System a Connection to an Open Drain System2. Water-CooledCondenser DCM-750BWH-OS Connection to a Closed Loop Systemb Connection to a Closed Loop System G. Final Checklist H. Startup I. Controls and Adjustments 1. Portion ControlIII. Cleaning and Maintenance A. Cleaning and Sanitizing InstructionsaCleaning Solution bCleaning Procedure1. Water System cSanitizing Solution bSanitizing Solution2. Dispensing Components cCleaning and Sanitizing Procedure Fig.B. Maintenance C. Preparing the Icemaker for Long Storage 6Close the drain valves 7Replace the panels in their correct positionsHOSHIZAKI AMERICA, INC