Hoshizaki DCM-750BAH(-OS), DCM-750BWH(-OS) DCM-750BWH-OS, Connection to a Closed Loop System, Fig

Page 21
b) Connection to a Closed Loop System

b) Connection to a Closed Loop System

Condenser water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" OD copper tubing is recommended for the condenser water supply line.

Condenser return outlet is 3/8" FPT. A minimum of 3/8" OD hard pipe is recommended for the condenser return line.

Shut-off valves and drain valves should be installed at both the condenser water supply inlet and condenser return outlet.

The water supply to the condenser should not drop below 4 GPM.

The pressure differential between the condenser water supply inlet and condenser return outlet must be no less than 10 PSIG.

When using a glycol blend, the solution mixture should be less than 30% glycol.

In order to maintain the proper high side pressure, the condenser water supply inlet temperature should not drop below 45°F (7°C) and the condenser return outlet temperature must be in the 104°F to 115°F (40°C to 46°C) range. Once the icemaker installation is complete, confirm the condenser return outlet temperature 5 minutes after a freeze cycle starts. If the outlet temperature is not in the proper range, adjust the water‑regulating valve to bring it into range.

Storage Bin

Drain Outlet

3/4" FPT

Drip Tray

Drain Outlet

3/4" FPT

Icemaker

Stand

Vent

Tube

Icemaker Water

 

Supply Inlet

Icemaker Water Supply

1/2" FPT

 

Line Shut-Off Valve

Condenser

Icemaker Water Supply

Return Outlet

3/8" FPT

Line Drain Valve

 

Condenser Return

 

Line Shut-Off Valve

 

Condenser Water Supply

 

Line Shut-Off Valve

 

Condenser Return

 

Line Drain Valve

DCM-750BWH(-OS)Connection to a Closed Loop SystemManual backgroundManual backgroundManual backgroundCondenser Water Supply Condenser Water Line Drain Valve Supply Inlet

1/2" FPT

Separate piping to approved drain. Leave a two-inch (5 cm) vertical air gap between the end of each pipe and the drain.

Two-inch (5 cm) air gap

Fig. 6

DCM-750BWH(-OS)

Floor Drain

 

Connection to a Closed Loop System

21

Image 21
Contents Cubelet Icemaker / Dispenser Models DCM-750BAH-OS DCM-750BWH-OS INSTRUCTION MANUALHoshizakiHoshizaki America, Inc HOSHIZAKI AMERICA, INC 618 Highway 74 South •Complete and detailed explanation of the problemPeachtree City, GA Attn: Hoshizaki Technical Support DepartmentCONTENTS Important Safety Information I. Specifications A. Nameplate Rating HOSHIZAKI ICE MAKERHoshizaki America, Inc 2. DCM-750BAH-OS air-cooled 3. DCM-750BWH water-cooled 4. DCM-750BWH-OS water-cooled 1. DCM-750BAH B. Dimensions/Connections2. DCM-750BAH-OS 3. DCM-750BWH 4. DCM-750BWH-OS SD-700 26-1/2673 SD-750 26-3/4680 SD-700 80-11/162050 SD-750 80-15/162057SD-700 SD-750A.Checks Before Installation II. Installation and Operating InstructionsFig. B. How to Remove PanelsDCM-750B_H DCM-750B_H-OSC. Location D.SetupELECTRICAL CONNECTION E. Electrical ConnectionSee Fig. 4, 5, or F. Water Supply and Drain Connections1. Icemaker DCM-750BAH-OSDCM-750BWH-OS Connection to an Open Drain System a Connection to an Open Drain System2. Water-CooledCondenser DCM-750BWH-OS Connection to a Closed Loop Systemb Connection to a Closed Loop System G. Final Checklist H. Startup 1. Portion Control I. Controls and AdjustmentsA. Cleaning and Sanitizing Instructions III. Cleaning and MaintenanceaCleaning Solution bCleaning Procedure1. Water System cSanitizing Solution bSanitizing Solution2. Dispensing Components Fig. cCleaning and Sanitizing ProcedureB. Maintenance C. Preparing the Icemaker for Long Storage 7Replace the panels in their correct positions 6Close the drain valvesHOSHIZAKI AMERICA, INC