e)Pump-Out Frequency Control (dip switch 5 & 6)
The pump motor drains the water tank at the frequency set by the
The
Dip Switch Setting | Frequency | ||
No. 5 | No. 6 | ||
| |||
OFF | OFF | every cycle | |
ON | OFF | every 2 cycles | |
OFF | ON | every 5 cycles | |
ON | ON | every 10 cycles |
f) Freeze Timer (dip switch 9 & 10)
CAUTION
Adjust to proper specification, or the unit may not operate correctly.
The freeze timer setting determines the maximum allowed freeze time to prevent possible
The freeze timer is factory adjusted and no adjustment is required.
Dip Switch Setting | Time | |
No. 9 | No. 10 | (minutes) |
| ||
|
|
|
OFF | OFF | 60 |
OFF | ON | 50 |
ON | OFF | 70 |
ON | ON | 60 |
g) Bin Control
CAUTION
Dip Switch No. 7 must be set to the ON position. If No. 7 is set to the OFF position, the machine will run continuously, causing a
This machine uses a
(1) Explanation of Operation
A resistor wire harness connects the bin control to the K4 connector on the control board. When the bin control is calling for ice (proximity switch closed), a 7.9 KΩ reading is sent to the control board to continue operation. When the bin control is activated in the bin full position (proximity switch open), a 15.8 KΩ signal is sent to the control board to
15