SANITIZING PROCEDURE

Use sanitizer to remove algae or slime. Do not use it to remove lime scale or other mineral deposits.

Step 1 Set the toggle switch to the OFF position after ice falls from the evaporator at the end of a Harvest cycle. Or, set the switch to the OFF position and allow the ice to melt off the evaporator.

!Caution

Never use anything to force ice from the evaporator. Damage may result.

!Warning

Disconnect electric power to the ice machine (and dispenser if applicable) at the electric switch box before proceeding.

Step 2

Remove all ice from the bin.

Step 3

Refer to Removal of Parts For Cleaning/

Sanitizing and remove ice machine parts. Step 4 Mix a solution of water and sanitizer.

Solution Type

Water

Mixed With

Sanitizer

4 gal. (15 l)

3 oz (90 ml) sanitizer

Step 5 Use the sanitizing solution and a sponge or cloth to sanitize (wipe) all parts and interior surfaces of the ice machine. Sanitize the following areas:

A.Side walls

B.Base (area above water trough)

C.Evaporator plastic parts

D.Bin or dispenser

Step 6 Rinse all sanitized areas with clear water.

Step 7 Install the removed parts, restore power and place toggle switch in the ice position.

Step 8 T o start a sanitizing cycle, move the toggle switch to the CLEAN position. The water will flow through the water dump valve and down the drain. The Clean light will turn on to indicate the ice machine is in the sanitizing mode.

Step 9 Wait about two minutes or untill water starts to flow over the evaporator.

Step 10 Add the proper amount of Manitowoc Ice Machine Sanitizer to the water trough by pouring between the water curtain and evaporator.

Model

Amount of Sanitizer

S1400M

9 ounces (266 ml)

Step 11 The ice machine will automatically time out a ten minute sanitizing cycle, followed by six rinse cycles, and stop. The Clean light will turn off to indicate the sanitizing cycle is completed. This entire cycle lasts approximately 30 minutes.

Step 12 When the sanitizing process stops, move the toggle switch to ICE position.

4-4

Part Number 80-1631-3

Image 26
Contents S1400M Model Ice Machines Installation Use and Care Manual Read These Before Proceeding Personal Injury PotentialTable of Contents Section Before Calling For Service Table of ContentsSection Maintenance Section Ice Machine OperationModel Numbers How to Read a Model NumberSection General Information Ice Cube SizesGeneral Information Section Accessories Section General Information Model/Serial Number Location Model/Serial Number LocationWarranty Coverage General Section Installation InstructionsIce Machine Dimensions S1400M WATER-COOLED ICE MachinesInstallation Instructions Section Location of Ice Machine Ice Machine Heat of RejectionMinimum Circuit Ampacity Section Installation Instructions Electrical ServiceVoltage Electrical RequirementsSelf Contained ICE Machine 208-230/3/60 For United Kingdom OnlySelf Contained ICE Machine 115/1/60 or 208-230/1/60 Self Contained ICE Machine 230/1/50Water Inlet Lines Cooling Tower ApplicationsWater Supply Drain ConnectionsWater Supply and Drain Line SIZING/CONNECTIONS Installation Instructions SectionTypical Water Supply Drain Installation Section Installation Instructions Installation Check List AuCS Automatic Cleaning System Potential Personal Injury SituationSection Ice Machine Operation Component IdentificationIce Machine Operation Section Sequence Of Operation Initial START-UP or START-UP After Automatic SHUT-OFFHarvest Safety TimersHarvest Sequence 5. Water Purge Automatic SHUT-OFF 7. Automatic Shut-OffICE Thickness Check Ice Machine Operation Section Operational ChecksWater Level Ice Thickness CheckWater Purge Adjustment Harvest Sequence Water PurgeIce Machine Operation Section Ice Machine Inspection Section MaintenanceExterior Cleaning Water-Cooled Condenser Water Regulating ValveSachet Replacement Frequency Maintenance Section GuardianInstallation Sachet Replacement ProcedureStep Section Maintenance Interior Cleaning and SanitizingCleaning Procedure Maintenance Section Sanitizing ProcedureRemoval of Parts for CLEANING/SANITIZING Ice Thickness Probe Removal Water CurtainWater Curtain Removal Ice Thickness Probe Water Distribution Tube Removal Water Distribution TubeWater Trough Water Pump Removal Water Level ProbeWater Pump Dump Valve Disassembly Water Dump ValveEvaporator Tray Removal Drain Line Check ValveWater Inlet Valve SELF-CONTAINED WATER-COOLED ICE Machines Maintenance Section Removal from Service/WinterizationPry Open the Water Regulating Valve AUCS→ Accessory Section Before Calling For Service ChecklistBefore Calling For Service Section Safety Limit FeaturePage Manitowoc ICE, INC

S1400M specifications

The Manitowoc Ice S1400M is a cutting-edge ice machine designed for high volume ice production, widely popular in the restaurant and hospitality industries. This model is part of Manitowoc’s acclaimed line of ice machines, known for their durability, efficiency, and innovative features that simplify ice making while enhancing operational performance.

One of the most notable features of the S1400M is its impressive production capacity. This unit is capable of producing up to 1,400 pounds of ice per day, making it a reliable choice for businesses with high ice demands. Whether it's for cocktails, beverages, or food preservation, the S1400M ensures that there is always enough ice available to meet customer needs.

The S1400M employs Manitowoc's advanced ice-making technology, which includes a state-of-the-art 100% stainless steel evaporator. This not only enhances the longevity of the unit but also helps produce cleaner and clearer ice. The unit utilizes a patented built-in actuator that completely purges the evaporator during the harvest cycle, ensuring that the ice is free from contaminants and undesirable residues.

Furthermore, the Manitowoc S1400M is designed with energy efficiency in mind. It operates with the Energy Star certification, which means it meets strict energy efficiency guidelines set by the U.S. Environmental Protection Agency. This reduces operational costs and environmental impact, making the S1400M an excellent investment for eco-conscious businesses.

This model is also equipped with an intuitive ice thickness control system, allowing for customization of ice size according to specific needs. Users can easily set the machine to produce either half-cube or full-cube ice, catering to varying beverage requirements. Additionally, the S1400M features a user-friendly interface and digital display, providing operators with real-time machine status updates and alerts for maintenance or service needs.

Another important aspect of the S1400M is its flexible installation options. This unit can be paired with a variety of bins and dispensers, allowing businesses to optimize their space while ensuring the functionality of their ice supply. Its compact design is ideal for establishments with limited space, making it a versatile choice for bars, restaurants, and hotels.

In summary, the Manitowoc Ice S1400M represents the perfect blend of power, efficiency, and technological advancement. With its high production capacity, durable construction, customizable ice production, and energy-saving features, the S1400M stands out as a leading choice for any business requiring consistent and high-quality ice.