Manitowoc Ice S1800M manual Water Trough, Water Distribution Tube Removal

Page 29

Section 4

Maintenance

 

 

3. Water Distribution Tube

!Warning

Removing the distribution tube while the water pump is running will allow water to spray from ice machine. Disconnect the electrical power to the ice machine and dispenser at the electric service switch box and turn off the water supply.

NOTE: Distribution tube thumbscrews are retained by o- rings to prevent loss. Loosen thumbscrews but do not pull thumbscrews out of distribution tube.

A

B

4.Water Trough

A.Depress tabs on right and left side of the water trough.

B.Allow front of water trough to drop as you pull forward to disengage the rear pins.

DEPRESS TABS

Water Distribution Tube Removal

A.Remove outer half of distribution tube by loosening the four (4) thumbscrews (o-rings retain thumbscrews to distribution tube).

B.Pull inner half of water distribution tube forward to release slip joint from water pump tubing connection.

Part Number 80-1633-3

4-7

Image 29
Contents S1800M Model Ice Machines Installation Use and Care Manual Personal Injury Potential Read These Before ProceedingTable of Contents Section Before Calling For Service Table of Contents Section Ice Machine OperationSection Maintenance Section General Information How to Read a Model NumberModel Numbers Ice Cube SizesGeneral Information Section Accessories Model/Serial Number Location Section General Information Model/Serial Number LocationWarranty Coverage Ice Machine Dimensions Section Installation InstructionsGeneral S1800 WATER-COOLED ICE MachinesIce Machine Heat of Rejection Installation Instructions Section Location of Ice MachineVoltage Section Installation Instructions Electrical ServiceMinimum Circuit Ampacity Electrical RequirementsSelf Contained ICE Machine 115/1/60 or 208-230/1/60 For United Kingdom OnlySelf Contained ICE Machine 208-230/3/60 Self Contained ICE Machine 230/1/50Water Supply Cooling Tower ApplicationsWater Inlet Lines Drain ConnectionsWater Supply and Drain Line SIZING/CONNECTIONS Installation Instructions SectionTypical Water Supply Drain Installation Section Installation Instructions Installation Check List Potential Personal Injury Situation AuCS Automatic Cleaning SystemComponent Identification Section Ice Machine OperationSection Ice Machine Operation Initial START-UP or START-UP After Automatic SHUT-OFF Ice Machine Operation Section Sequence Of OperationHarvest Sequence 5. Water Purge Safety TimersHarvest Automatic SHUT-OFF 7. Automatic Shut-OffWater Level Ice Machine Operation Section Operational ChecksICE Thickness Check Ice Thickness CheckHarvest Sequence Water Purge Water Purge AdjustmentIce Machine Operation Section Exterior Cleaning Section MaintenanceIce Machine Inspection Water-Cooled Condenser Water Regulating ValveInstallation Maintenance Section GuardianSachet Replacement Frequency Sachet Replacement ProcedureStep Section Maintenance Interior Cleaning and SanitizingCleaning Procedure Sanitizing Procedure Maintenance SectionRemoval of Parts for CLEANING/SANITIZING Ice Thickness Probe Removal Water CurtainWater Curtain Removal Ice Thickness Probe Water Distribution Tube Removal Water Distribution TubeWater Trough Water Pump Removal Water Level ProbeWater Pump Water Dump Valve Dump Valve DisassemblyDrain Line Check Valve Evaporator Tray RemovalWater Inlet Valve SELF-CONTAINED WATER-COOLED ICE Machines Maintenance Section Removal from Service/WinterizationPry Open the Water Regulating Valve AUCS→ Accessory Checklist Section Before Calling For ServiceSafety Limit Feature Before Calling For Service SectionPage Manitowoc ICE, INC