Section 2

Installation Instructions

 

 

Electrical Service

GENERAL

!Warning

All wiring must conform to local, state and national codes.

VOLTAGE

The maximum allowable voltage variation is ±10% of the rated voltage at ice machine start-up (when the electrical load is highest).

Important

Observe correct polarity of incoming line voltage.

Fuse/Circuit Breaker

A separate fuse/circuit breaker must be provided for each ice machine. Circuit breakers must be H.A.C.R. rated (does not apply in Canada).

MINIMUM CIRCUIT AMPACITY

The minimum circuit ampacity is used to help select the wire size of the electrical supply. (Minimum circuit ampacity is not the ice machine’s running amp load.)

!Warning

The ice machine must be grounded in accordance with national and local electrical codes.

S Series Ice Machines (* indicates preliminary data)

The wire size (or gauge) is also dependent upon location, materials used, length of run, etc., so it must be determined by a qualified electrician.

ELECTRICAL REQUIREMENTS

Refer to Ice Machine Model/Serial Plate for voltage/ amperage specifications.

Ice Machine

Voltage Phase

 

Water Cooled

Maximum Fuse/Circuit

 

Cycle

Minimum Circuit Amps

 

Breaker

 

 

 

 

 

 

208-230/1/60

40

 

22.1

S1800

208-230/3/60

20

 

12.0

 

230/1/50

40

 

20.5

Part Number 80-1633-3

2-3

Image 11
Contents S1800M Model Ice Machines Installation Use and Care Manual Personal Injury Potential Read These Before ProceedingTable of Contents Section Before Calling For Service Table of Contents Section Ice Machine OperationSection Maintenance Ice Cube Sizes How to Read a Model NumberSection General Information Model NumbersGeneral Information Section Accessories Model/Serial Number Location Section General Information Model/Serial Number LocationWarranty Coverage S1800 WATER-COOLED ICE Machines Section Installation InstructionsIce Machine Dimensions GeneralIce Machine Heat of Rejection Installation Instructions Section Location of Ice MachineElectrical Requirements Section Installation Instructions Electrical ServiceVoltage Minimum Circuit AmpacitySelf Contained ICE Machine 230/1/50 For United Kingdom OnlySelf Contained ICE Machine 115/1/60 or 208-230/1/60 Self Contained ICE Machine 208-230/3/60Drain Connections Cooling Tower ApplicationsWater Supply Water Inlet LinesWater Supply and Drain Line SIZING/CONNECTIONS Installation Instructions SectionTypical Water Supply Drain Installation Section Installation Instructions Installation Check List Potential Personal Injury Situation AuCS Automatic Cleaning SystemComponent Identification Section Ice Machine OperationSection Ice Machine Operation Initial START-UP or START-UP After Automatic SHUT-OFF Ice Machine Operation Section Sequence Of OperationAutomatic SHUT-OFF 7. Automatic Shut-Off Safety TimersHarvest Sequence 5. Water Purge HarvestIce Thickness Check Ice Machine Operation Section Operational ChecksWater Level ICE Thickness CheckHarvest Sequence Water Purge Water Purge AdjustmentIce Machine Operation Section Water-Cooled Condenser Water Regulating Valve Section MaintenanceExterior Cleaning Ice Machine InspectionSachet Replacement Procedure Maintenance Section GuardianInstallation Sachet Replacement FrequencyStep Section Maintenance Interior Cleaning and SanitizingCleaning Procedure Sanitizing Procedure Maintenance SectionRemoval of Parts for CLEANING/SANITIZING Ice Thickness Probe Removal Water CurtainWater Curtain Removal Ice Thickness Probe Water Distribution Tube Removal Water Distribution TubeWater Trough Water Pump Removal Water Level ProbeWater Pump Water Dump Valve Dump Valve DisassemblyDrain Line Check Valve Evaporator Tray RemovalWater Inlet Valve SELF-CONTAINED WATER-COOLED ICE Machines Maintenance Section Removal from Service/WinterizationPry Open the Water Regulating Valve AUCS→ Accessory Checklist Section Before Calling For ServiceSafety Limit Feature Before Calling For Service SectionPage Manitowoc ICE, INC