WattMaster WHP | Section 2 |
|
|
Connect To Next WHP Controller And/Or MiniLink On Local Loop
Local Loop
9600 Baud
Outside Air
Temp. Sensor
WHP Loop Controller Expansion Board
C21 |
|
| U3 |
| D1 |
|
CX1 | U2 CX2 | CX3 |
|
| ||
RN1 | CX4 |
| ||||
| 1 |
|
|
|
|
|
| U1 |
|
| U4 |
|
|
TB1 |
|
|
|
| RLY1 | V1 |
COMM |
|
|
|
| D2 |
|
T |
|
|
|
| V2 | |
|
|
|
|
| ||
|
|
|
|
|
| |
SHLD |
|
|
|
| V3 | |
|
|
|
|
| ||
RCX5 |
|
|
|
| RLY2 | |
LD6 | U5 |
|
|
| D3 | |
|
| PAL |
| R1 | ||
|
|
|
| |||
COMM |
|
|
| 1 | ||
RAM | EPROM |
| R2 | |||
LD7 | COMM |
|
|
| RLY3 | |
1 | HH |
| R3 | |||
PWR |
| |||||
|
|
| (1 MEG) |
| ||
LD8 | RN3 | U6 | YS101816 REV. 2 | RN2 | D4 | R4 |
LED1 |
|
| ||||
LD9 |
| C1 |
|
|
| R5 |
LED2 | P1 |
|
|
| RLY4 | |
|
|
|
|
| ||
R1 | +VREF |
| CX6 |
| TB2 | |
|
|
| D5 | |||
| 5.11V |
|
|
|
|
R (24 VAC By Others)
R1 Compressor Enable
R2 Main Pump
R3 Standby Pump
N.C. Pilot Duty Relays
Return Water Temp Sensor
Supply Water Temp Sensor
See Note 4
| U7 TEST POINT |
|
|
| PHILIPS |
|
| |
| RV1 | EWDOG |
|
|
|
| ||
|
|
|
|
|
|
| ||
| VREF ADJ |
| R28 |
|
|
|
| |
INPUTS |
|
| ADDRESS |
| ADD | |||
| +VDC |
|
|
|
|
|
| 1 |
|
|
|
|
|
|
| 2 | |
| RN5 |
|
|
|
|
| ||
|
|
|
|
|
| 4 | ||
| AIN1 |
| PU1 |
|
|
|
| |
|
|
|
|
|
| 8 | ||
| AIN2 |
| D6 |
|
|
|
| 16 |
|
| PU2 |
|
|
|
| 32 | |
| AIN3 |
| D7 |
|
|
|
| TOKEN |
|
| PU3 |
|
|
|
| NETWORK | |
| AIN4 |
|
| SW1 |
|
| ||
|
| PU4 |
|
|
| |||
|
|
|
|
|
|
| ||
| AIN5 |
| D9 |
|
|
|
|
|
|
| PU5 |
|
|
|
|
| |
| GND C10 | D11 |
| VDC |
| VDC |
| |
| PU7 | X2 | ||||||
| GND |
| D14 |
|
|
|
| JP1 |
| C12 |
|
|
|
|
|
| |
| AOUT1 | U13 |
|
|
|
| R15 | |
|
|
|
|
|
|
| ||
| AOUT2 |
|
|
|
|
|
| C14 |
| AIN7 |
|
| CX13 |
|
| R19 | |
| GND | C17 | D15 |
|
|
| ||
|
|
|
| U15 |
| C15 | ||
TB3 | PJ1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| R22 |
|
|
|
|
|
|
|
| R24 |
C2 |
|
|
|
|
|
| X1 |
|
|
|
|
C3 | 1 |
| RLY5 |
|
|
| RN4 |
|
|
|
|
| U9 |
|
|
| CX8 |
CX10 |
|
| C7 |
|
|
U10 |
| D10 | R7 |
|
|
|
|
| L1 | D13 | R10 |
C11 | CX12 |
|
|
|
|
|
| D12 |
|
| |
|
|
| R13 |
|
|
|
|
| SC1 |
|
|
U12 |
|
|
|
|
|
CX14 |
|
|
|
|
|
U14 |
|
|
|
|
|
|
|
| D19 |
|
|
|
|
|
|
| D16 |
R11
V4
V5
U8
NE5090NPB3192
0PS
R6
C9 |
|
9936 | U11 |
MC34064A |
|
C13
C16
TB4
GND
(By Others)
Alarm Indicator
Required VA For Transformer
Loop Controller = 8VA Min.
GND
Optional Pressure Transmitter
Proof of Flow
| C20 | R25 |
| CX15 | |
| R26 | PJ3 |
PRESSURE | PJ2 | |
SENSOR |
|
|
EXPANSION |
|
D17 | D18 | C18 | C19 |
|
|
| 7824CT |
|
|
| M |
T'STAT VR1 | VR2 |
24VAC
Line Voltage
24VAC
See Note 1
Manual Reset
Phase
Loss
Pump VFD | - | |
+ | ||
| ||
|
| |
|
| |
Optional | - | |
+ | ||
Modulating Heat |
Notes:
1.)24 VAC Must Be Connected So
That All Ground Wires Remain
Common.
2.)All Wiring To Be In Accordance With Local And National Electrical Codes And Specifications.
3.)All Communication Wiring To Be 2 Conductor Twisted Pair With Shield. Use Belden #82760 Or Equivalent.
4.)When a Water Pressure Transmitter Is Used, a 250 Ohm Resistor is Installed Between AIN3 & GND and The Pull Up Resistor PU3 is Removed.
| N.C. Pilot Duty Relays |
| (By Others) |
Heating/Cooling #1 | R4 |
Heating/Cooling #2 | R5 |
Heating/Cooling #3 | R6 |
Heating/Cooling #4 | R7 |
24 VAC |
|
Heating/Cooling #1 | R8 |
Heating/Cooling #2 | R9 |
Heating/Cooling #3 | R10 |
Heating/Cooling #4 | R11 |
24 VAC |
|
Fire Alarm Contact (N.C.)(See Note 5) | |
Request to Run Contact (N.O.) | |
| Relay Contacts |
| (By Others) |
GND | 24VAC |
4RLY IO BD. YS101790
4RLY IO BD. YS101790
AIN1
AIN2
AIN3
AIN4
GND
AOUT1
4 ANALOG IN MOD I/O BD. YS101784
5.)If a Fire Alarm Contact is Not Connected to AIN1 on The Analog Expansion Board, Then a Jumper Must Installed Between AIN1 and GND.
WHP Loop Controller Expansion Board
WHP Loop Controller Wiring
Figure2-4:
Installation and Wiring |