Manitowoc Ice S1800M manual Section Before Calling For Service, Checklist

Page 35

Section 5

Before Calling For Service

 

 

Section 5

Before Calling For Service

Checklist

If a problem arises during operation of your ice machine, follow the checklist below before calling service. Routine adjustments and maintenance procedures are not covered by the warranty.

Problem

Possible Cause

To Correct

Ice machine does not operate.

No electrical power to the ice machine

Replace the fuse/reset the breaker/turn

 

and/or condensing unit.

on the main switch.

 

High pressure cutout tripping.

Clean condenser coil. (See Section 4)

 

ICE/OFF/CLEAN toggle switch set

Move the toggle switch to the ICE

 

improperly.

position.

 

Water curtain stuck open.

Water curtain must be installed and

 

 

swinging freely. (See Section 4)

Ice machine stops, and can be restarted

Safety limit feature stopping the ice

Refer to “Safety Limit Feature” on the

by moving the toggle switch to OFF and

machine.

next page.

back to ICE.

 

 

Ice machine does not release ice or is

Ice machine is dirty.

Clean and sanitize the ice machine.

slow to harvest.

 

(See Section 4)

 

Ice machine is not level.

Level the ice machine. (See Section 2)

 

Low air temperature around ice machine

Air temperature must be at least 35°F

 

head section.

(1.6°C).

Ice machine does not cycle into harvest

The six-minute freeze time lock-in has

Wait for the freeze lock-in to expire.

mode.

not expired yet.

 

 

Ice thickness probe is dirty.

Clean and sanitize the ice machine.

 

 

(See Section 4)

 

Ice thickness probe is disconnected.

Connect the wire.

 

Ice thickness probe is out of adjustment.

Adjust the ice thickness probe.

 

 

(See Section 3)

 

Uneven ice fill (thin at the top of

Verify sufficient water level in sump

 

evaporator).

trough. Contact a qualified service

 

 

company to check refrigeration system.

Ice quality is poor (soft or not clear).

Poor incoming water quality.

Contact a qualified service company to

 

 

test the quality of the incoming water and

 

 

make appropriate filter

 

 

recommendations.

 

Water filtration is poor.

Replace the filter.

 

Ice machine is dirty.

Clean and sanitize the ice machine.

 

 

(See Section 4)

 

Water dump valve is not working.

Disassemble and clean the water dump

 

 

valve. (See Section 4)

 

Water softener is working improperly (if

Repair the water softener.

 

applicable).

 

Part Number 80-1633-3

5-1

Image 35
Contents S1800M Model Ice Machines Installation Use and Care Manual Personal Injury Potential Read These Before ProceedingTable of Contents Section Before Calling For Service Table of Contents Section Ice Machine OperationSection Maintenance Ice Cube Sizes How to Read a Model NumberSection General Information Model NumbersGeneral Information Section Accessories Model/Serial Number Location Section General Information Model/Serial Number LocationWarranty Coverage S1800 WATER-COOLED ICE Machines Section Installation InstructionsIce Machine Dimensions GeneralIce Machine Heat of Rejection Installation Instructions Section Location of Ice MachineElectrical Requirements Section Installation Instructions Electrical ServiceVoltage Minimum Circuit AmpacitySelf Contained ICE Machine 230/1/50 For United Kingdom OnlySelf Contained ICE Machine 115/1/60 or 208-230/1/60 Self Contained ICE Machine 208-230/3/60Drain Connections Cooling Tower ApplicationsWater Supply Water Inlet LinesWater Supply and Drain Line SIZING/CONNECTIONS Installation Instructions SectionTypical Water Supply Drain Installation Section Installation Instructions Installation Check List Potential Personal Injury Situation AuCS Automatic Cleaning SystemComponent Identification Section Ice Machine OperationSection Ice Machine Operation Initial START-UP or START-UP After Automatic SHUT-OFF Ice Machine Operation Section Sequence Of OperationAutomatic SHUT-OFF 7. Automatic Shut-Off Safety TimersHarvest Sequence 5. Water Purge HarvestIce Thickness Check Ice Machine Operation Section Operational ChecksWater Level ICE Thickness CheckHarvest Sequence Water Purge Water Purge AdjustmentIce Machine Operation Section Water-Cooled Condenser Water Regulating Valve Section MaintenanceExterior Cleaning Ice Machine InspectionSachet Replacement Procedure Maintenance Section GuardianInstallation Sachet Replacement FrequencyStep Section Maintenance Interior Cleaning and SanitizingCleaning Procedure Sanitizing Procedure Maintenance SectionRemoval of Parts for CLEANING/SANITIZING Ice Thickness Probe Removal Water CurtainWater Curtain Removal Ice Thickness Probe Water Distribution Tube Removal Water Distribution TubeWater Trough Water Pump Removal Water Level ProbeWater Pump Water Dump Valve Dump Valve DisassemblyDrain Line Check Valve Evaporator Tray RemovalWater Inlet Valve SELF-CONTAINED WATER-COOLED ICE Machines Maintenance Section Removal from Service/WinterizationPry Open the Water Regulating Valve AUCS→ Accessory Checklist Section Before Calling For ServiceSafety Limit Feature Before Calling For Service SectionPage Manitowoc ICE, INC