Ice-O-Matic installation manual Bearing Maintenance, Note Left Hand Threads, MFI Series, Page

Page 23
Bearing Maintenance

MFI Series

Bearing Maintenance

Bearing Maintenance:

The bearing in the breaker should also be checked at least two (2) times per year.

Switch the machine OFF and check the bearing.

1. Remove the chute cover.

2.Unscrew the ice sweep

3.Removing the water shed and unscrewing the breaker cover.

Note: Left Hand Threads

4. Unscrewing the auger stud

5.Inspect the bearing. There should be plenty of grease in sight. If grease is needed the bearing and breaker should be removed to check the action of the bearing.

It should rotate freely.

6.To remove the breaker, remove the lower ice chute then take out all four (4) Allen head cap screws and pull the breaker off the auger and evaporator.

7.If the bearing only needs grease, inject grease into the bearing using a grease needle.

See Removal and Replacement Section to replace bearings and seals.

Page 17

Image 23
Contents Denver, Colorado SERVICE AND INSTALLATION MANUAL MFI SeriesIce-O-Matic 11100 East 45th AvePage Page MFI SeriesIntroduction Keep this manual for future referencePage Table Of ContentsTable of Contents MFI SeriesConcealed Loss or Damage Freight Claim ProcedureInspect Promptly Visible Loss or DamagePage WarrantyMFI Series Adjustments For the InstallerInstallation Guidelines Electrical SpecificationsPage For The InstallerMFI Series MFI Series Ice Machine SpecificationsBin Application For the InstallerWater Limitations LocationStorage Bin Ice machinePage For the InstallerMFI Series Allow 6 “Clearance for Air CirculationAIR COOLED MODELS For the PlumberWater Inlet WATER COOLED MODELSAir Cooled Models For the ElectricianElectrical Connections Water Cooled ModelsPage Final Check ListFor the Installer MFI SeriesMFI Series Start UpPre-StartInspection Start UpPage Component DescriptionAir Cooled Model Shown MFI SeriesPage MFI SeriesComponent Description Potential Relay The compressor start relayIce Sweep Bearing Breaker/Divider Auger MFI SeriesComponent Description PageShut Down To ResetElectrical Sequence Electrical SequencePage Operation WaterWater System MFI SeriesTypical Low Side Pressure High Pressure Cut Out- Automatic ResetLow Pressure Cut Out- Automatic Reset Operation PerformanceKEEP OUT OF THE REACH OF CHILDREN Sanitizing and CleaningICE MAKING SYSTEM In place cleaning scheduled at a minimum of twice a yearMFI Series Bearing MaintenanceBearing Maintenance Note Left Hand ThreadsMFI Series Sensor MaintenanceBin Control Sensor Water SensorPage Maintenance Air CooledClean the air cooled condenser MFI Series2. Turn off the water supply to the ice machine Auger Maintenance1. Disconnect electrical power to the ice machine AugerProbable Correction Service DiagnosisSymptom Possible CausePossible Cause Service DiagnosisSymptom MFI SeriesPage Control System Diagnostics4.High pressure cut out check MFI SeriesMFI Series R&R- Water Reservoir, Bin ControlWater Reservoir Bin Controls Ice Level SensorsPage To Remove the Breaker Bearing AssemblyR&R-Bearingand Breaker MFI SeriesPage R&R-AugerTo Remove the Auger MFI SeriesTo Replace the Water Seal R&R-WaterSealTo Remove the Water Seal Removal of the Water SealMFI Series R&R-EvaporatorTo Replace the Evaporator To Reassemble the Evaporator and AugerTo Inspect the Gear Motor To Remove and Repair the Gear Motor AssemblyR&R-GearMotor To Check the Gear MotorPage To Remove the Condenser Fan Motor AssemblyR&R-FanBlade and Motor MFI SeriesInstructions for Liquid Charging R404A Refrigeration System ServiceService RefrigerationPage MFI0500 Wiring DiagramWiring Diagram MFI0500 Air, MFI0500 Water MFI SeriesPage MFI0800 Wiring DiagramMFI Series Page MFI0805/1255 Wiring DiagramWiring Diagram MFI0805, MFI1255 Air MFI SeriesPage MFI1256 Wiring DiagramWiring Diagram MFI1256 Air MFI SeriesPage Service HistoryWhat to Do Before Calling for Service MFI Series