Ice-O-Matic R&R-Bearingand Breaker, To Remove the Breaker Bearing Assembly, MFI Series, Page

Page 31
R&R-Bearing and Breaker

MFI Series

R&R-Bearing and Breaker

Note: Removal of the auger, water seal, evaporator and gear motor must begin at the top of the assembly.

To Remove the Breaker Bearing Assembly:

1. Disconnect electrical power.

2. Remove panels.

3. Push back bail clamp and remove ice chute cover.

4. Unscrew and remove ice sweep.

5. Lift up and remove ice chute.

6. The breaker may be removed from the auger and evaporator without disturbing the auger. a. Unscrew breaker cover from breaker (Note: Left Hand Threads)

b. Unscrew auger stud from top of auger. (Fig. 1)

c. Unscrew four (4) Allen head cap screws holding breaker to evaporator. (Fig 2)

d. Lift up, and remove breaker/bearing assembly from auger and evaporator. (Fig 3)

7.Service the bearing. Check for rust, rough spots and damage.

a.The bearing is pressed into the breaker, to remove the bearing and replace it, an arbor press is needed.

b.Replace lower seals before installing new bearing in breaker. Note: Seals must be pressed in with a tool pushing against the outer edge only, they will not install by hand.

c.Replace parts as required. Re-grease bearings with Ice-O-Matic PN6051062-01 bearing grease.

d.Replace top seal and check the O-Rings, replace if cut or torn.

8.Reverse to reassemble: Specific tools and materials are required to install properly.

a.Add food grade grease such as Ice-O-Matic PN6051036-01 to the seal area before installing on the auger.

b.Check the seal to shaft areas for cuts or rough spots, none are permitted.

Fig. 1

Fig. 2

Fig. 3

 

 

Bearing

 

Ice Sweep

Seals

Auger Stud

Breaker Cover

Page 25

Image 31
Contents Denver, Colorado SERVICE AND INSTALLATION MANUAL MFI SeriesIce-O-Matic 11100 East 45th AvePage Page MFI SeriesIntroduction Keep this manual for future referencePage Table Of ContentsTable of Contents MFI SeriesConcealed Loss or Damage Freight Claim ProcedureInspect Promptly Visible Loss or DamageMFI Series WarrantyPage Adjustments For the InstallerInstallation Guidelines Electrical SpecificationsMFI Series For The InstallerPage MFI Series Ice Machine SpecificationsBin Application For the InstallerWater Limitations LocationStorage Bin Ice machinePage For the InstallerMFI Series Allow 6 “Clearance for Air CirculationAIR COOLED MODELS For the PlumberWater Inlet WATER COOLED MODELSAir Cooled Models For the ElectricianElectrical Connections Water Cooled ModelsPage Final Check ListFor the Installer MFI SeriesMFI Series Start UpPre-StartInspection Start UpPage Component DescriptionAir Cooled Model Shown MFI SeriesPage MFI SeriesComponent Description Potential Relay The compressor start relayIce Sweep Bearing Breaker/Divider Auger MFI SeriesComponent Description PageShut Down To ResetElectrical Sequence Electrical SequencePage Operation WaterWater System MFI SeriesTypical Low Side Pressure High Pressure Cut Out- Automatic ResetLow Pressure Cut Out- Automatic Reset Operation PerformanceKEEP OUT OF THE REACH OF CHILDREN Sanitizing and CleaningICE MAKING SYSTEM In place cleaning scheduled at a minimum of twice a yearMFI Series Bearing MaintenanceBearing Maintenance Note Left Hand ThreadsMFI Series Sensor MaintenanceBin Control Sensor Water SensorPage Maintenance Air CooledClean the air cooled condenser MFI Series2. Turn off the water supply to the ice machine Auger Maintenance1. Disconnect electrical power to the ice machine AugerProbable Correction Service DiagnosisSymptom Possible CausePossible Cause Service DiagnosisSymptom MFI SeriesPage Control System Diagnostics4.High pressure cut out check MFI SeriesMFI Series R&R- Water Reservoir, Bin ControlWater Reservoir Bin Controls Ice Level SensorsPage To Remove the Breaker Bearing AssemblyR&R-Bearingand Breaker MFI SeriesPage R&R-AugerTo Remove the Auger MFI SeriesTo Replace the Water Seal R&R-WaterSealTo Remove the Water Seal Removal of the Water SealMFI Series R&R-EvaporatorTo Replace the Evaporator To Reassemble the Evaporator and AugerTo Inspect the Gear Motor To Remove and Repair the Gear Motor AssemblyR&R-GearMotor To Check the Gear MotorPage To Remove the Condenser Fan Motor AssemblyR&R-FanBlade and Motor MFI SeriesInstructions for Liquid Charging R404A Refrigeration System ServiceService RefrigerationPage MFI0500 Wiring DiagramWiring Diagram MFI0500 Air, MFI0500 Water MFI SeriesMFI Series MFI0800 Wiring DiagramPage Page MFI0805/1255 Wiring DiagramWiring Diagram MFI0805, MFI1255 Air MFI SeriesPage MFI1256 Wiring DiagramWiring Diagram MFI1256 Air MFI SeriesPage Service HistoryWhat to Do Before Calling for Service MFI Series