Ice-O-Matic R&R-GearMotor, To Check the Gear Motor, To Inspect the Gear Motor, MFI Series

Page 35
R&R-Gear Motor

MFI Series

R&R-Gear Motor

To Check the Gear Motor:

1.Remove wires from terminals 1 and 2

2.Use an ohmeter to check for continuity. If there is none, replace only the motor. If there is continuity but the motor will not start, check the motor’s start switch.

3.Remove motor end bell or motor stator. With ohmeter wires attached to 1 and 2 move centrifugal switch actuator up and down to simulate motor rotation. If the ohmeter does not show any change, replace the switch or motor. If the ohmeter showns an open circuit, replace the switch or motor.

To Remove and Repair the Gear Motor Assembly:

(Assuming that the procedures through removal of the water seal have been performed)

1.Remove the electrical wires from the gear drive motor.

2.Unscrew the four (4) cap screws holding the gear motor to the base of the machine.

remove the gear motor from the machine.

Note: Bench test the gear motor, check for oil leaks, noise and amp draw.

To Inspect the Gear Motor:

1.Remove the cap screws holding the gear motor case halves together and pry the two cases apart.

2.To lift off the cover, lift up until you can feel internal contact, then pull the cover towards the output gear end, and lift up the cover (with drive motor attached) up and away from the gear motor case. Note: The gearcase cover, output bearings and output shaft are a pressed together assembly.

3.Inspect the oil gears and bearings. If there is evidence of water in the oil (rusty metal, too much oil, white oil) replace the oil and damaged parts.

4.The oil charge is 14 ounces. Do not overfill.

5.Reassemble and bench test the gear motor, check for oil leaks, noise and amp draw.

Cover and Output

Gear Assembly

Water Shed

Centrifugal Switch

Auger Drive

Motor

Rotor Bearing

Page 29

Image 35
Contents Denver, Colorado SERVICE AND INSTALLATION MANUAL MFI SeriesIce-O-Matic 11100 East 45th AvePage Page MFI SeriesIntroduction Keep this manual for future referencePage Table Of ContentsTable of Contents MFI SeriesConcealed Loss or Damage Freight Claim ProcedureInspect Promptly Visible Loss or DamagePage WarrantyMFI Series Adjustments For the InstallerInstallation Guidelines Electrical SpecificationsPage For The InstallerMFI Series MFI Series Ice Machine SpecificationsBin Application For the InstallerWater Limitations LocationStorage Bin Ice machinePage For the InstallerMFI Series Allow 6 “Clearance for Air CirculationAIR COOLED MODELS For the PlumberWater Inlet WATER COOLED MODELSAir Cooled Models For the ElectricianElectrical Connections Water Cooled ModelsPage Final Check ListFor the Installer MFI SeriesMFI Series Start UpPre-StartInspection Start UpPage Component DescriptionAir Cooled Model Shown MFI SeriesPage MFI SeriesComponent Description Potential Relay The compressor start relayIce Sweep Bearing Breaker/Divider Auger MFI SeriesComponent Description PageShut Down To ResetElectrical Sequence Electrical SequencePage Operation WaterWater System MFI SeriesTypical Low Side Pressure High Pressure Cut Out- Automatic ResetLow Pressure Cut Out- Automatic Reset Operation PerformanceKEEP OUT OF THE REACH OF CHILDREN Sanitizing and CleaningICE MAKING SYSTEM In place cleaning scheduled at a minimum of twice a yearMFI Series Bearing MaintenanceBearing Maintenance Note Left Hand ThreadsMFI Series Sensor MaintenanceBin Control Sensor Water SensorPage Maintenance Air CooledClean the air cooled condenser MFI Series2. Turn off the water supply to the ice machine Auger Maintenance1. Disconnect electrical power to the ice machine AugerProbable Correction Service DiagnosisSymptom Possible CausePossible Cause Service DiagnosisSymptom MFI SeriesPage Control System Diagnostics4.High pressure cut out check MFI SeriesMFI Series R&R- Water Reservoir, Bin ControlWater Reservoir Bin Controls Ice Level SensorsPage To Remove the Breaker Bearing AssemblyR&R-Bearingand Breaker MFI SeriesPage R&R-AugerTo Remove the Auger MFI SeriesTo Replace the Water Seal R&R-WaterSealTo Remove the Water Seal Removal of the Water SealMFI Series R&R-EvaporatorTo Replace the Evaporator To Reassemble the Evaporator and AugerTo Inspect the Gear Motor To Remove and Repair the Gear Motor AssemblyR&R-GearMotor To Check the Gear MotorPage To Remove the Condenser Fan Motor AssemblyR&R-FanBlade and Motor MFI SeriesInstructions for Liquid Charging R404A Refrigeration System ServiceService RefrigerationPage MFI0500 Wiring DiagramWiring Diagram MFI0500 Air, MFI0500 Water MFI SeriesPage MFI0800 Wiring DiagramMFI Series Page MFI0805/1255 Wiring DiagramWiring Diagram MFI0805, MFI1255 Air MFI SeriesPage MFI1256 Wiring DiagramWiring Diagram MFI1256 Air MFI SeriesPage Service HistoryWhat to Do Before Calling for Service MFI Series