Start Up

Pre-Start Inspection:

1.Remove the front and side service panels.

2.Check that any shipping blocks have been removed.

3.Inspect the interior of the ice machine for loose screws or wires.

4.Check that no refrigerant lines are rubbing each other.

5.Check that the fan blades turn freely (Air Cooled).

6.Check that the unit is installed correctly according to the final check list on page 8.

Start Up:

1.Go through the pre-start inspection.

2.Open the hand valve, observe that water enters the water reservoir, fills the tube from the water reservoir to the evaporator and then shuts off. (Water cooled only, Turn the water supply ON to the water cooled condenser). Check for leaks.

3.Switch the master (mode) switch ON. The electrical start up sequence in automatic.

a.There should be a short (15 second) delay before the gear motor starts.

b.After the gear motor starts, the compressor will start.

4.On air cooled models, the condenser will begin to discharge warm air, on water cooled models, the water regulating valve will open and warm water will be discharged into the drain.

5.The unit should soon be making ice, if desired; the low side pressure may be checked: it should be 32 psig +/- 2 psig.

The suction line temperature at the compressor is normally very cold, nearly to the point of frost up to the compressor body, but not on it.

The air cooled discharge pressure will depend upon air and water temperatures, but should be between 200 psig and 280 psig.

The water cooled discharge pressure should be a constant at about 245 psig.

Note: The above pressures are for new, clean machines. You can expect to see some values higher, and some lower between different units.

6.There are no adjustments to make, so replace the panels.

7.Clean and/or sanitize the storage bin interior, wipe off the exterior with a clean, damp cloth.

8.Give the owner/user the service manual, instruct him/her in the operation of the unit, and make sure they know who to call for service.

9.Fill out the manufacturer’s registration and mail it to Ice-O-Matic.

Page 9

Image 15
Contents Denver, Colorado SERVICE AND INSTALLATION MANUAL MFI SeriesIce-O-Matic 11100 East 45th AvePage Page MFI SeriesIntroduction Keep this manual for future referencePage Table Of ContentsTable of Contents MFI SeriesConcealed Loss or Damage Freight Claim ProcedureInspect Promptly Visible Loss or DamageWarranty MFI SeriesPage Adjustments For the InstallerInstallation Guidelines Electrical SpecificationsFor The Installer MFI SeriesPage MFI Series Ice Machine SpecificationsBin Application For the InstallerWater Limitations LocationStorage Bin Ice machinePage For the InstallerMFI Series Allow 6 “Clearance for Air CirculationAIR COOLED MODELS For the PlumberWater Inlet WATER COOLED MODELSAir Cooled Models For the ElectricianElectrical Connections Water Cooled ModelsPage Final Check ListFor the Installer MFI SeriesMFI Series Start UpPre-StartInspection Start UpPage Component DescriptionAir Cooled Model Shown MFI SeriesPage MFI SeriesComponent Description Potential Relay The compressor start relayIce Sweep Bearing Breaker/Divider Auger MFI SeriesComponent Description PageShut Down To ResetElectrical Sequence Electrical SequencePage Operation WaterWater System MFI SeriesTypical Low Side Pressure High Pressure Cut Out- Automatic ResetLow Pressure Cut Out- Automatic Reset Operation PerformanceKEEP OUT OF THE REACH OF CHILDREN Sanitizing and CleaningICE MAKING SYSTEM In place cleaning scheduled at a minimum of twice a yearMFI Series Bearing MaintenanceBearing Maintenance Note Left Hand ThreadsMFI Series Sensor MaintenanceBin Control Sensor Water SensorPage Maintenance Air CooledClean the air cooled condenser MFI Series2. Turn off the water supply to the ice machine Auger Maintenance1. Disconnect electrical power to the ice machine AugerProbable Correction Service DiagnosisSymptom Possible CausePossible Cause Service DiagnosisSymptom MFI SeriesPage Control System Diagnostics4.High pressure cut out check MFI SeriesMFI Series R&R- Water Reservoir, Bin ControlWater Reservoir Bin Controls Ice Level SensorsPage To Remove the Breaker Bearing AssemblyR&R-Bearingand Breaker MFI SeriesPage R&R-AugerTo Remove the Auger MFI SeriesTo Replace the Water Seal R&R-WaterSealTo Remove the Water Seal Removal of the Water SealMFI Series R&R-EvaporatorTo Replace the Evaporator To Reassemble the Evaporator and AugerTo Inspect the Gear Motor To Remove and Repair the Gear Motor AssemblyR&R-GearMotor To Check the Gear MotorPage To Remove the Condenser Fan Motor AssemblyR&R-FanBlade and Motor MFI SeriesInstructions for Liquid Charging R404A Refrigeration System ServiceService RefrigerationPage MFI0500 Wiring DiagramWiring Diagram MFI0500 Air, MFI0500 Water MFI SeriesMFI0800 Wiring Diagram MFI SeriesPage Page MFI0805/1255 Wiring DiagramWiring Diagram MFI0805, MFI1255 Air MFI SeriesPage MFI1256 Wiring DiagramWiring Diagram MFI1256 Air MFI SeriesPage Service HistoryWhat to Do Before Calling for Service MFI Series