Manitowoc Ice Q130 manual Section Installation Instructions Leveling the Ice Machine

Page 11

Section 2

Installation Instructions

 

 

Leveling the Ice Machine

THREAD LEVELING

LEG INTO BASE OF

CABINET

Checking Ice Machine Level

1.Screw the leveling legs onto the bottom of the ice machine.

2.Screw the foot of each leg in as far as possible.

!Caution

The legs must be screwed in tightly to prevent them from bending.

3.Move the ice machine into its final position.

4.Level the ice machine to assure that the siphon system functions correctly. Use a level on top of the ice machine. Turn each foot as necessary to level the ice machine from front to back and side to side.

NOTE: An optional 2 ½" caster assembly is available for use in place of the legs on the Q130, Q210 and Q270. Installation instructions are supplied with the casters.

Part Number 000001130 12/08

2-3

Image 11
Contents Q130/Q210/Q270 UnderCounter Model Ice Machines Personal Injury Potential Safety NoticesProcedural Notices Read These Before ProceedingTable of Contents Section Before Calling for Service Table of Contents Section OperationSection Maintenance Model Numbers AccessoriesSection General Information Ice Machine Model Number Serial Number General Information Section Model/Serial Number LocationQ270 Models Model/Serial Number LocationGeneral Commercial Warranty Coverage GeneralAuthorized Warranty Service Service CallsGeneral Information Section Q130/Q210 ICE Machines Section Installation InstructionsIce Machine Dimensions GeneralSeries Heat of Rejection Ice Machine Air Conditioning Peak Installation Instructions Section Location of Ice MachineIce Machine Heat of Rejection Checking Ice Machine Level Section Installation Instructions Leveling the Ice MachineInstallation Instructions Section Electrical Service Drain Connections Section Installation Instructions Water Service/DrainsWater Supply Water Inlet LinesTypical Water Supply Drain Installation Personal Injury Potential Installation Instructions Section Installation Checklist Component Identification OperationInitial START-UP or START-UP After Automatic SHUT-OFF Operation Section Ice Making Sequence of OperationSection Operation Energized Parts Chart Water Float Valve Check Operation Section Operational ChecksSiphon System Siphon System CheckIce Thickness Check Section OperationWater Level Check ICE Bridge Thickness CheckOperation Section Cleaning and Sanitizing Procedure Section MaintenanceInterior Cleaning and Sanitizing Maintenance Section Float Valve Removal Q130 ModelsQ130 Water Distribution Tube Removal Q210/Q270 InstallationRemove the Water Trough Remove the ice damper Q130Remove the Bin Door Solution Type Water Mixed withSolution Type Water Mixed With Sanitizer Model Amount of Sanitizer Exterior CleaningICE Machine Inspection Water-Cooled Condenser Water Regulating Valve Cleaning the CondenserAir-Cooled Condenser Pry Open the Water Regulating Valve Maintenance Section Removal From Service WinterizationSELF-CONTAINED AIR-COOLED ICE Machines WATER-COOLED ICE MachinesThis page Intentionally Left Blank Maintenance Section Problem Possible Cause To Correct Section Before Calling for ServiceChecklist Safety Limit Feature Before Calling for Service SectionSafety Limit Notes Safety LimitsSafety Limit Stand-By Mode Determining Which Safety Limit Stopped The Ice MachinePossible Cause Check/Correct Safety Limit #1Safety Limit #2 This page Intentionally Left Blank