Manitowoc Ice Q130 manual Typical Water Supply Drain Installation

Page 14

Installation Instructions

Section 2

 

 

Water Supply and Drain Line Sizing/Connections

!Caution

Plumbing must conform to state and local codes.

Location

Water

Water

Ice Machine

Tubing Size Up to Ice

Temperature

Pressure

Fitting

Machine Fitting

 

 

 

 

 

 

Ice Making

40°F (4.4°C) Min.

20 psi (137.9 kPA) Min.

3/8” Female Pipe

3/8” (9.5 mm) minimum

Water Inlet

°

°

C) Max.

80 psi (551.5 kPA) Max.

Thread

inside diameter

90 F (32.2

 

 

 

 

 

 

 

 

3/8” Female Pipe

3/8” (9.5 mm) minimum

Condenser Water

40°F (4.4°C) Min.

20 psi (137.9 kPA) Min.

Thread

inside diameter

Q270 Only

Q270 Only

Inlet

90°F (32.2°C) Max.

150 psi (1034.2 kPA) Max.

1/2” Female Pipe

1/2” (12.7 mm)

 

 

 

 

 

 

 

 

 

 

Thread

minimum inside diameter

 

 

 

 

 

 

Condenser Water

---

 

---

1/2” Female Pipe

1/2” (12.7 mm) minimum

Drain

 

 

 

 

Thread

inside diameter

 

 

 

 

 

 

 

---

 

---

1/2” Female Pipe

1/2” (12.7 mm) minimum

Bin Drain

 

 

 

 

Thread

inside diameter

 

 

 

 

 

 

 

VENT TUBING 8”

(20CM) LONG

BIN DRAIN

CONDENSER

WATER DRAIN

TUBING 1/2” MIN. ID

(1.27CM)

CONDENSER

WATER INLET

TUBING

WATER

SHUTOFF

VALVE

ICE MAKING WATER

INLET TUBING 3/8”

MIN. ID (0.95CM)

Typical Water Supply Drain Installation

2-6

Part Number 000001130 12/08

Image 14
Contents Q130/Q210/Q270 UnderCounter Model Ice Machines Read These Before Proceeding Safety NoticesProcedural Notices Personal Injury PotentialTable of Contents Section Before Calling for Service Table of Contents Section OperationSection Maintenance Model Numbers AccessoriesSection General Information Model/Serial Number Location General Information Section Model/Serial Number LocationQ270 Models Ice Machine Model Number Serial NumberService Calls Commercial Warranty Coverage GeneralAuthorized Warranty Service GeneralGeneral Information Section General Section Installation InstructionsIce Machine Dimensions Q130/Q210 ICE MachinesSeries Heat of Rejection Ice Machine Air Conditioning Peak Installation Instructions Section Location of Ice MachineIce Machine Heat of Rejection Section Installation Instructions Leveling the Ice Machine Checking Ice Machine LevelInstallation Instructions Section Electrical Service Water Inlet Lines Section Installation Instructions Water Service/DrainsWater Supply Drain ConnectionsTypical Water Supply Drain Installation Personal Injury Potential Installation Instructions Section Installation Checklist Operation Component IdentificationOperation Section Ice Making Sequence of Operation Initial START-UP or START-UP After Automatic SHUT-OFFSection Operation Energized Parts Chart Siphon System Check Operation Section Operational ChecksSiphon System Water Float Valve CheckICE Bridge Thickness Check Section OperationWater Level Check Ice Thickness CheckOperation Section Cleaning and Sanitizing Procedure Section MaintenanceInterior Cleaning and Sanitizing Maintenance Section Float Valve Removal Q130 ModelsQ130 Water Distribution Tube Removal Q130 InstallationRemove the Water Trough Remove the ice damper Q210/Q270Remove the Bin Door Solution Type Water Mixed withSolution Type Water Mixed With Sanitizer Model Amount of Sanitizer Exterior CleaningICE Machine Inspection Water-Cooled Condenser Water Regulating Valve Cleaning the CondenserAir-Cooled Condenser WATER-COOLED ICE Machines Maintenance Section Removal From Service WinterizationSELF-CONTAINED AIR-COOLED ICE Machines Pry Open the Water Regulating ValveThis page Intentionally Left Blank Maintenance Section Problem Possible Cause To Correct Section Before Calling for ServiceChecklist Before Calling for Service Section Safety Limit FeatureDetermining Which Safety Limit Stopped The Ice Machine Safety LimitsSafety Limit Stand-By Mode Safety Limit NotesSafety Limit #1 Possible Cause Check/CorrectSafety Limit #2 This page Intentionally Left Blank