Manitowoc Ice Q130 manual Section Maintenance, Interior Cleaning and Sanitizing

Page 23

Section 4

Maintenance

Interior Cleaning and Sanitizing

GENERAL

Clean and sanitize the ice machine every six months for efficient operation. If the ice machine requires more frequent cleaning and sanitizing, consult a qualified service company to test the water quality and recommend appropriate water treatment.

The ice machine must be taken apart for cleaning and sanitizing.

!Caution

Use only Manitowoc approved Ice Machine Cleaner (part number 94-0546-3) and Sanitizer (part number 94-0565-3). It is a violation of Federal law to use these solutions in a manner inconsistent with their labeling. Read and understand all labels printed on bottles before use.

CLEANING AND SANITIZING PROCEDURE

!Caution

Do not mix Ice Machine Cleaner and Sanitizer solutions together. It is a violation of Federal law to use these solutions in a manner inconsistent with their labeling.

!Warning

Wear rubber gloves and safety goggles (and/or face shield) when handling Ice Machine Cleaner or Sanitizer.

Ice machine cleaner is used to remove lime scale and mineral deposits. Ice machine sanitizer disinfects and removes algae and slime.

Step 1 Set the toggle switch to the OFF position after ice falls from the evaporator at the end of a Harvest cycle. Or, set the switch to the OFF position and allow the ice to melt off the evaporator.

!Caution

Never use anything to force ice from the evaporator. Damage may result.

Step 2 Remove all ice from the bin.

Step 3 To start a cleaning cycle, move the toggle switch to the WASH position.

Step 4 Add the proper amount of Manitowoc Ice Machine Cleaner to the water trough.

Model

Amount of Cleaner

Q130

1 ounces (30 ml)

Q210

2 ounces (60 ml)

Q270

2 ounces (60 ml)

Step 5 Wait until the clean cycle is complete (approximately 22 minutes) then place the toggle switch in the OFF position, disconnect power and water supplies to the ice machine.

!Warning

Disconnect electric power to the ice machine at the electric switch box before proceeding.

Step 6 Remove parts for cleaning.

A.Remove the Vinyl Hose

Disconnect the water hose from the distribution tube and water pump.

B.Remove Water Pump

Disconnect the water pump power cord.

DO NOT SOAK

WATER PUMP MOTOR IN

CLEANER OR SANITIZER

SOLUTIONS

Water Pump Removal

Loosen the screws securing the pump- mounting bracket to the bulkhead.

Lift the pump and bracket assembly off the mounting screws.

Part Number 000001130 12/08

4-1

Image 23
Contents Q130/Q210/Q270 UnderCounter Model Ice Machines Personal Injury Potential Safety NoticesProcedural Notices Read These Before ProceedingTable of Contents Section Before Calling for Service Table of Contents Section OperationSection Maintenance Model Numbers AccessoriesSection General Information Ice Machine Model Number Serial Number General Information Section Model/Serial Number LocationQ270 Models Model/Serial Number LocationGeneral Commercial Warranty Coverage GeneralAuthorized Warranty Service Service CallsGeneral Information Section Q130/Q210 ICE Machines Section Installation InstructionsIce Machine Dimensions GeneralSeries Heat of Rejection Ice Machine Air Conditioning Peak Installation Instructions Section Location of Ice MachineIce Machine Heat of Rejection Checking Ice Machine Level Section Installation Instructions Leveling the Ice MachineInstallation Instructions Section Electrical Service Drain Connections Section Installation Instructions Water Service/DrainsWater Supply Water Inlet LinesTypical Water Supply Drain Installation Personal Injury Potential Installation Instructions Section Installation Checklist Component Identification OperationInitial START-UP or START-UP After Automatic SHUT-OFF Operation Section Ice Making Sequence of OperationSection Operation Energized Parts Chart Water Float Valve Check Operation Section Operational ChecksSiphon System Siphon System CheckIce Thickness Check Section OperationWater Level Check ICE Bridge Thickness CheckOperation Section Cleaning and Sanitizing Procedure Section MaintenanceInterior Cleaning and Sanitizing Maintenance Section Float Valve Removal Q130 ModelsQ130 Water Distribution Tube Removal Q210/Q270 InstallationRemove the Water Trough Remove the ice damper Q130Remove the Bin Door Solution Type Water Mixed withSolution Type Water Mixed With Sanitizer Model Amount of Sanitizer Exterior CleaningICE Machine Inspection Water-Cooled Condenser Water Regulating Valve Cleaning the CondenserAir-Cooled Condenser Pry Open the Water Regulating Valve Maintenance Section Removal From Service WinterizationSELF-CONTAINED AIR-COOLED ICE Machines WATER-COOLED ICE MachinesThis page Intentionally Left Blank Maintenance Section Problem Possible Cause To Correct Section Before Calling for ServiceChecklist Safety Limit Feature Before Calling for Service SectionSafety Limit Notes Safety LimitsSafety Limit Stand-By Mode Determining Which Safety Limit Stopped The Ice MachinePossible Cause Check/Correct Safety Limit #1Safety Limit #2 This page Intentionally Left Blank