GE Monogram GXSF30H installation instructions Care and cleaning of the water softening system

Page 17

Care and cleaning of the water softening system.

GEAppliances.com

Checking the Salt Storage Level and Refilling

 

Brine (salt dissolved in water) is needed for each and every recharge. The water for making brine is metered into the salt storage area by the water softening system valve and control.

However, you must keep the tank supplied with salt.

When to refill with salt: Check the salt level a few weeks after you install the water softening system and periodically after that. Refill when the tank gets less than 1/3 full. In humid areas it is best to refill with less salt and more often, to avoid forming a salt bridge (see page 12). Never allow the softening system to use all the salt before you refill it. Without salt, you will soon have hard water.

Use clean water softening salts only, at least 99.5% pure. NUGGET, PELLET or coarse SOLAR salts are recommended. Do not use rock, block, granulated or ice cream making salts.

They contain dirt and sediments, or mush and cake, and will create maintenance problems.

CAUTION: Water softening salt with iron removing additives: Some salts may have an additive to help the water softening system handle iron in the water supply. Although this additive may help to keep the water softening system resin clean, it may also release corrosive fumes that weaken and shorten the life of some water softening system parts. GE recommends using only Diamond Crystal® Red•Out® brand salt.

Cleaning Iron Out of the Water Softening System

Your water softening system takes hardness minerals (calcium and magnesium) out of the water. Also, it can control some (see the Specification Guidelines section) “clear water” iron. With clear water iron, water from a faucet is clear when first put into a glass. After 15 to 30 minutes, the water begins to cloud or turn rust colored. A water softening system will not remove any iron that makes the water cloudy or rusty as it comes from the faucet (called red water iron). To take red water iron out of water, or over the maximum of clear water iron,

an iron filter or other equipment is needed.

GE recommends using only Diamond Crystal® Red•Out® brand salts with Iron Fighter® additive to help keep the resin bed clean of clear iron. If your water supply has clear water iron, periodic resin bed cleaning is needed. GE recommends using Super Iron Out® brand resin bed cleaner to thoroughly clean your resin bed if your iron content is high. Clean the bed at least every six months, or more often if iron appears in the soft water between cleanings.

IMPORTANT: It is important to mix the resin bed cleaner with water (following the manufacturer’s instructions), pour it into the brinewell tube (see page 5) and recharge the softener immediately. Do not pour the resin bed cleaner in with the salt, as it will not be as effective in cleaning the resin, and can cause damage to the softener if it is left in the brine tank for an extended period due to the corrosive gases that are formed.

17

Image 17
Contents Write the model and serial numbers here Model # Serial # 7277886 215C1173P016 49-50160-108-05 JRSafety Precautions Unpacking and Inspection Installation instructionsImportant Installation Recommendations Tools and Materials Required for Installation Plan How You Will Install the SoftenerWhere to Install the Softener Optional 3-Valve Bypass Installation Illustration Typical Installation IllustrationInstall Bypass Valve Step-by-step installation instructionsMove the Softener Assembly Into Installation Position Plumb in and OUT Pipes to and from SoftenerInstall the Brine Tank Overflow Fittings and Hose 4A. Connecting a Rigid Valve Drain TubeInstall Grounding Clamp Connect to Electrical PowerSET Present Time of DAY Programming the ControlSET Water Hardness Number SET Recharge Starting TimeError Signals Optional Control SettingsSYSTEM/ELECTRONIC Diagnostics Salt EfficiencySpecifications/Dimensions Sanitizing ProceduresAbout the water softener system Do not overtighten the cap Cleaning the Nozzle and Venturi AssemblyBreaking a Salt Bridge Feature Memory Feature Optional Recharge ControlsFeature/Service Automatic Electronic Diagnostics Normal Operation, Control Displays Service Timer/Softener, Service Checkout Procedure Service Electronic Demand Time Features and Service Possible Defect Visual ChecksOpen a Nearby Soft Water Faucet If the code was changed, make ALL the timer settingsIf the water softening system does not draw brine, check Cleaning Iron Out of the Water Softening System Care and cleaning of the water softening systemChecking the Salt Storage Level and Refilling However, you must keep the tank supplied with saltThat does not mix soft and hard water Before you call for service…Problem Possible Causes What To Do No soft water Not using any salt After installationWater feels slippery Water softening systemSalty tasting or Brown/yellow colored Water after installationBrown/yellow Colored water Resin beads showingGEAppliances.com Parts list GEAppliances.com General Electric Parts Catalog Parts catalogSupport Screen Warrantor General Electric Company. Louisville, KY What Is Not CoveredFor The Period Of We Will Replace For The Period We Will Replace GE Water Softening System Warranty. For Customers in CanadaPage Información de seguridad Instrucciones para la Advertencia No use con agua que AdvertenciaAdvertencia No use con Instrucciones de instalaciónDesempacado e inspección Recomendaciones importantes para la instalaciónHerramientas y materiales necesarios para la instalación Planifique la instalación del DescalcificadorDónde instalar el Descalcificador Principal Ilustración de instalación normalInstale LA Válvula DE Bypass Instrucciones de instalación paso por paso4A. Cómo Conectar UN Tubo DE Drenaje DE Válvula Rígida DE LA VálvulaConecte EL Suministro Eléctrico Instale LA Abrazadera DE TierraAgregue Agua Y SAL AL Tanque DE Salmuera Ajuste LA Hora DEL DÍA Programación del controlAjuste EL Nivel DE Dureza DEL Agua Ajuste LA Hora DE Inicio DE RecargaAjustes opcionales de control Señales DE ErrorDiagnóstico ELECTRÓNICO/DEL Sistema Eficiencia DE LA SALProcedimientos de desinfección Especificaciones/DimensionesSobre el sistema de descalcificación de agua Cómo romper un puente de sal Junta Tapón de flujo Cómo limpiar la ensambladura de la boquilla y el VenturiFunción Memoria Operación normal, Pantalla de controlCaracterística/Servicio Diagnóstico electrónico automático Recargue Esta NocheInspecciones Visuales VisualizadoServicio Diagnóstico electrónico iniciado manualmente Recharge recargo Servicio Inspección manual del avance de la racargaPrecaución Antes de llamar para solicitar servicio… No HAY Agua DESCALCIFICADA-Problemas más comunesVeces el agua El agua sabe a sal o tiene Notas Notas Notas 146 999 Lista de partesGEAppliances.com Catálogo DE Partes DE General Electric Catálogo de partesPASADOR, Expansión Por el período de Reemplazamos Garantía GE para el Sistema de Descalcificación de AguaLo que no está cubierto Garante General Electric Company. Louisville, KYSolicite una reparación Soporte al Consumidor Página Web de GE AppliancesGarantías ampliadas Piezas y accesoriosParts and Accessories Schedule ServiceConsumer Support GE Appliances Website Real Life Design Studio