GE Monogram GXSF30H installation instructions Support Screen

Page 25

GEAppliances.com

GENERAL ELECTRIC PARTS CATALOG

 

 

 

G

 

 

 

X

 

 

 

S

 

 

 

F

 

 

 

3

 

 

 

0

 

 

 

H

REF. NO.

GE PART NO.

PART DESCRIPTION

(01)

0111

WS19X10005

SUPPORT SCREEN

1

0112

WS03X10013

SCREEN

1

0113

WS22X10020

FLOW PLUG, .10 GPM

1

0114

WS08X10005

GASKET & ASPIRATOR

1

0115

WS03X10015

CONE SCREEN

1

0116

WS22X10021

PLUG, FILL FLOW, .30 GPM

1

0117

WS03X10017

FERRULE NUT

1

0118

WS15X10034

NOZZLE/VENTURI BODY

1

0119

WS03X10018

RETAINER

1

0120

WS03X10019

SEAL, O-RING, 1/4″ X 3/8″

2

0121

WS15X10010

BODY, VALVE

1

0122

WS03X10020

SPRING

1

0123

WS22X10022

PLUG, DRAIN SEAL

1

0124

WS15X10009

NOZZLE/VENTURI ASM.

1

0130

WS35X10005

SEAL KIT, 3/4″

1

0132

WS22X10023

ADAPTER, DRAIN HOSE

1

0133

WS03X10021

O-RING, 5/8″ X 13/16″

1

0134

WS03X10022

PLUG, FLOW, RINSE CONTROL

1

0135

WS03X10023

CLIP

1

0136

WS26X10003

CAM & GEAR

1

0137

WS26X10004

BEARING

1

0138

WS26X10005

PLATE, MOTOR, 3/4″

1

0139

WS02X10015

SCREW, #6-20 X 3/8″

2

0140

WS26X10011

MOTOR ASM.

1

0141

WS02X10016

SCREW, #6-20 X 7/8″

2

0142

WS60X10001

NUT, INSTALLATION

2

0143

WS60X10002

TUBE, INSTALLATION

2

0144

WS60X10003

WASHER

2

0145

WS60X10004

CLIP

2

0146

WS28X10017

HARNESS WIRE, SENSOR ASSY., 3/4″

1

0147

WS19X10006

TURBINE & SUPPORT ASM.

1

0150

WS03X10024

SEAL, O-RING

1

0151

WS15X10012

BYPASS ASM.

1

0152

WS03X10025

SEAL, O-RING

2

0153

WS60X10006

ADAPTER

2

0999

49-50160

OWNER’S MANUAL

1

 

WS35X10044

INSTALLATION KIT

1

NOTE: Codes in the State of Massachusetts require installation by a licensed plumber and do not permit the use of the saddle valve. For installation, use plumbing code 248-CMR of the Commonwealth of Massachusetts.

25

Image 25
Contents Write the model and serial numbers here Model # Serial # 7277886 215C1173P016 49-50160-108-05 JRSafety Precautions Important Installation Recommendations Installation instructionsUnpacking and Inspection Where to Install the Softener Plan How You Will Install the SoftenerTools and Materials Required for Installation Optional 3-Valve Bypass Installation Illustration Typical Installation IllustrationInstall Bypass Valve Step-by-step installation instructionsMove the Softener Assembly Into Installation Position Plumb in and OUT Pipes to and from SoftenerInstall the Brine Tank Overflow Fittings and Hose 4A. Connecting a Rigid Valve Drain TubeInstall Grounding Clamp Connect to Electrical PowerSET Present Time of DAY Programming the ControlSET Water Hardness Number SET Recharge Starting TimeError Signals Optional Control SettingsSYSTEM/ELECTRONIC Diagnostics Salt EfficiencySpecifications/Dimensions Sanitizing ProceduresAbout the water softener system Breaking a Salt Bridge Cleaning the Nozzle and Venturi AssemblyDo not overtighten the cap Feature Memory Feature Optional Recharge ControlsFeature/Service Automatic Electronic Diagnostics Normal Operation, Control DisplaysService Timer/Softener, Service Checkout Procedure Service Electronic Demand Time Features and ServicePossible Defect Visual ChecksOpen a Nearby Soft Water Faucet If the code was changed, make ALL the timer settingsIf the water softening system does not draw brine, check Cleaning Iron Out of the Water Softening System Care and cleaning of the water softening systemChecking the Salt Storage Level and Refilling However, you must keep the tank supplied with saltProblem Possible Causes What To Do No soft water Before you call for service…That does not mix soft and hard water Not using any salt After installationWater feels slippery Water softening systemSalty tasting or Brown/yellow colored Water after installationBrown/yellow Colored water Resin beads showingGEAppliances.com Parts list GEAppliances.com General Electric Parts Catalog Parts catalogSupport Screen For The Period Of We Will Replace What Is Not CoveredWarrantor General Electric Company. Louisville, KY For The Period We Will Replace GE Water Softening System Warranty. For Customers in CanadaPage Información de seguridad Instrucciones para la Advertencia No use con agua que AdvertenciaAdvertencia No use con Instrucciones de instalaciónDesempacado e inspección Recomendaciones importantes para la instalaciónDónde instalar el Descalcificador Planifique la instalación del DescalcificadorHerramientas y materiales necesarios para la instalación Principal Ilustración de instalación normalInstale LA Válvula DE Bypass Instrucciones de instalación paso por paso4A. Cómo Conectar UN Tubo DE Drenaje DE Válvula Rígida DE LA VálvulaAgregue Agua Y SAL AL Tanque DE Salmuera Instale LA Abrazadera DE TierraConecte EL Suministro Eléctrico Ajuste LA Hora DEL DÍA Programación del controlAjuste EL Nivel DE Dureza DEL Agua Ajuste LA Hora DE Inicio DE RecargaAjustes opcionales de control Señales DE ErrorDiagnóstico ELECTRÓNICO/DEL Sistema Eficiencia DE LA SALProcedimientos de desinfección Especificaciones/DimensionesSobre el sistema de descalcificación de agua Cómo romper un puente de sal Junta Tapón de flujo Cómo limpiar la ensambladura de la boquilla y el VenturiFunción Memoria Operación normal, Pantalla de controlCaracterística/Servicio Diagnóstico electrónico automático Recargue Esta NocheInspecciones Visuales VisualizadoServicio Diagnóstico electrónico iniciado manualmente Recharge recargo Servicio Inspección manual del avance de la racargaPrecaución Antes de llamar para solicitar servicio… No HAY Agua DESCALCIFICADA-Problemas más comunesVeces el agua El agua sabe a sal o tiene Notas Notas Notas 146 999 Lista de partesGEAppliances.com Catálogo DE Partes DE General Electric Catálogo de partesPASADOR, Expansión Por el período de Reemplazamos Garantía GE para el Sistema de Descalcificación de AguaLo que no está cubierto Garante General Electric Company. Louisville, KYSolicite una reparación Soporte al Consumidor Página Web de GE AppliancesGarantías ampliadas Piezas y accesoriosParts and Accessories Schedule ServiceConsumer Support GE Appliances Website Real Life Design Studio