Design Guide
THE INSTALLATION SPACE
The finished cutout width must be 35-1/2".
Finished Width
|
|
|
|
|
|
|
|
|
| Wall View | |||||||
|
|
|
|
| 7" |
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| 10" |
|
|
| Electrical |
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| Area |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
| 24" Cutout Depth |
|
|
| Floor to Bottom | |||||||||||
Finished |
|
|
|
|
| of Electrical | |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Opening |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| 5" |
|
|
| Water Supply |
| 5" |
|
| |||||
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
| 3 1/2" |
|
| 3 1/2" |
|
|
| |||||||||
|
|
|
Water And Electrical Locations
35"
Case Width
*84"
36"
Frame to Frame
Width
DIMENSIONS AND CLEARANCES
*Shipping height. The height may
be adjusted from
Product Clearances
These refrigerators are equipped with a 2 position door stop. The factory set 130° door swing can be adjusted to 90° if clearance to adjacent cabinets or walls is restricted.
The opening must be prepared with the electrical and water supply located as shown.
The cutout depth must be 24".
Designed for industry standard flush installation. The refrigerator will project forward, slightly beyond adjacent cabinetry, depending on your installation.
Additional Specifications
•A 115 volt 60Hz., 15 or 20 amp power supply is required. An individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded
Note: GFI (ground fault interrupter) is not recommended.
•Water line can enter the opening through the floor or back wall. The water line should be 1/4" O.D. copper tubing between the cold water line and water connection location, long enough to extend to the front of the refrigerator. Installation of an easily accessible shut off valve in the water line is recommended.
| 130° Door Swing | 90° Door Swing | |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 25" |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Minimum |
|
|
| 23 | ||||||||
|
|
| to Wall |
|
|
| Behind | ||||||||
|
|
|
|
|
|
|
|
|
| Frame | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
| 130° |
|
|
|
|
| 90° |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 4" Minimum | ||||||
|
|
|
|
|
|
|
|
| to Wall |
Allow 25" minimum clearance for a full 130° door swing. Allow 15" for pan removal.
4" minimum clearance is required when door swing is adjusted to 90°. If the 90° door stop position is used, pan access is maintained, but pan removal is re- stricted bottom pans.
See illustrations pages 4 and 5 to determine door swing interaction with adjacent cabinets or countertops.
ZUG2, ZUGSS2 Unified Grille Panel Kit
•If you are installing two refrigerators, side by side, the installation space must be
Note: Additional cutout width may be required when side panels are used. Add side panel thickness to the finished cutout to calculate
•The water and electrical locations for each product must be located as shown.
•A separate 115V, 60Hz., 15 or 20 amp power supply is recommended for each product.
10"
Opening
5" Water Supply
26"
|
|
|
|
|
|
|
|
|
| Wall View | |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| 7" |
|
| |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
10"
Floor to Bottom
of Electrical
Water Supply 5"
26"
3