Jackson AXL2-CMR, AXL2-CML technical manual CAM Timer Operation

Page 27

SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS

CAM TIMER OPERATION

The Conserver XL Series cam timer is a 1 minute, 30 second, 8-cam timer (cam 8 is a spare) that controls the operation of the dishmachine. The following is a description of the set points for each cam and the function of each switch.

CAM 1: Cam 1 is a cut cam with a single notch and serves as the cycle/reset control.

FUNCTION: When the machine is in the operation mode the notch is the home position. The machine will remain idle until the door is opened, then cam 1 moves to the start position and holds until the door is closed. The closing of the door will start the next cycle. The cam will rotate a complete cycle, and return to the home position and hold.

CAM 2: Cam 2 is a cut cam and provides the wash cycle timing.

FUNCTION: The wash cam works off the normally open contacts of Cam 2. This requires the microswitch be held closed by the cam. It will close and energize the wash pump 2 seconds after the cycle switch is activated. The pump will operate through the wash cycle (40 seconds) then shut down for the dwell period (20 seconds). As the cam rotates it energizes the pump for the rinse cycle (25 seconds). When cam 1 reaches it’s home position it will de-energize cam 2, shutting down the wash pump.

NOTE: The last 6 cams are adjustable. The following instructions will require that the timer position have the cams to the front and the motor to the left.

CAM 3: Cam 3 is an adjustable cam and controls the drain valve.

FUNCTION: The drain solenoid works off the normally closed contacts of cam 3. When the cycle is initiated, the microswitch will be held open until it is allowed to drop into the notch of the cam. This energizes the drain solenoid which drains the machine. After a 12 second delay the cam reverses the microswitch, de-energizing the drain solenoid. This cam may require adjusting due to varying water pressure. The drain solenoid must remain open long enough to remove whatever water the fill valve solenoid allows in the machine. This could vary due to the water supply line pressure.

SETTINGS: The right side of cam 3 must be set to pick up the switch arm just before the wash/rinse cycle cam switch drops. It will hold the drain solenoid open to drain all the water in the tank from the unit during the dwell period. Any adjustment made to the drain should be made to the left side of cam 3. The cam must be moved back into the wash time until all of the water is drained from the machine.

CAM 4: Cam 4 is an adjustable cam and controls the fill valve and therefore the amount of water used.

FUNCTION: The fill valve cam works off the normally closed contacts of cam 4. This requires the switch to be held open by the cam and allowed to drop into the notch to operate the fill valve. This energizes the fill solenoid which opens to start filling the machine with fresh water. After a 10 second delay, the cam reverses the microswitch, de-energizing the fill solenoid. The fill cam may require adjustment due to varying water pressure. The fill solenoid must remain open a sufficient length of time to fill the machine to the correct level.

SETTINGS: The right side of cam 4 must be set to allow the switch arm to drop 2 seconds before the drain solenoid is de-ener- gized which flushes the detergent residue from the unit. It will hold the fill solenoid open until the cam switch arm is raised. At that time the fill solenoid is de-energized, shutting off the incoming water. The tub will be filled to the correct level. Any adjust- ment made to the timing of the fill solenoid should be made with the left side of cam 4. To increase the water level, open the notch of the cam and for decreasing the level of the notch should be closed.

CAM 5: Cam 5 is an adjustable cam and controls the sanitizer pump.

FUNCTION: The sanitizer pump cam works off the normally closed contacts of cam 5. This requires the switch arm to be held open by the cam and allowed to drop into the notch to operate the pump. The time that the sanitizer pump will remain ener- gized must be determined in the field to suit the chemical used and water conditions.

SETTINGS: The left side of cam 5 must be set to allow the switch arm to drop in past the starting point of the fill cam and after the drain solenoid has closed. The adjustment for sanitizer volume must be made with the right side of the cam. To increase the volume the notch should be increased or to decrease the amount of sanitizer the notch should be closed slightly in incre- ments until the correct level is reached.

Conserver XL Series Technical Manual 7610-002-10-23

Issued: 11-28-2007 Revised: N/A

20

Image 27
Contents INSTALLATION/OPERATION Technical Manual ONE Year Limited Parts & Labor Warranty Manufacturers WarrantyStop Pare Arret Revision Made Applicable Details Date ECN Nomenclature for the Models Covered in this Manual Model Serial No Installation Date Service Rep. Name Phone NoTable of Contents Service Repair Centers Electrical DiagramsSection Specification Information Wash Pump Capacity Specification InformationOperating Cycle Seconds Wash Time Tank Capacity MinimumOperating Cycle Seconds TemperaturesDimensions Conserver AXL Dimensions Conserver AXL2 Dimensions Conserver AXL2-CML Rdimensions Conserver AXL2-CMR Dimensions Conserver XL Starting with S/N 04D10286 Dimensions Conserver XL2 Adjustable Bullet Feet Dimensions Conserver XL2-CML1232mm Dimensions Conserver XL2-CMRXLS Bowl Option Straight Through Installation Table DimensionsSection INSTALLATION/OPERATION Instructions Installation Instructions INSTALLATION/OPERATION InstructionsElectrical Instructions First-aid instructions Priming Chemical Feeder PumpsOperation Instructions INSTALLATION/OPERATION Instructions CAM Timer Operation INSTALLATION/OPERATION Instructions Mechanical Timer Timing Sequence Seconds Into Cycle INSTALLATION/OPERATION Instructions Universal Timer Programming Instructions Section Preventative Maintenance Preventative Maintenance Preventative MaintenanceSection Troubleshooting Section Troubleshooting Common Problems Domestic UnitsProblem Machine cycles continuously Problem Machine will not fill, other functions work Problem Wash motor runs continuouslyProblem Machine will not hold water Problem Machine will not drain Problem Machine runs with door openProblem Low pumped water pressure Problem Machine keeps tripping the service breakerProblem Prime switch does not activate sanitizer pump Problem Detergent not feeding rinse aid feeds okayProblem Rinse aid not feeding, detergent feeds okay Common Problems Export Units Problem Machine will not fill, other functions work Problem Machine runs with door open Problem Prime switch does not activate sanitizer pump Section Parts Section Parts Section Control BOX Assemblies Universal TimerQTY Description Control BOX Assemblies Mechanical Timer Control BOX Assembly with Mechanical Timer XLS Bowl Option Parts Section Timer Motor Microswitch Qty 05930-01-65-81 Mechanical 8 CAM Timer04320-002-82-28 Chemical Feeder Pump AssemblyHood Assembly Conserver XL2 Hood Assembly Cantilever ARM Double Bracket Mount Arm, Cantilever, Conserver XL Prior to S/N 04D10286 Conserver XL2 Cantilever ARM Assembly Single Bracket Mount False Panel Weldment 101 Conserver XL2 TUB Assembly Left Front View Conserver XL2 Series TUB Assembly Right Front View Conserver XL2 Series Frame Weldment & Accumulator Plumbing Assembly Incoming Plumbing AssembliesConserver AXL Incoming Coil & Housing only Solenoid Valve & 3/4 NPT Vacuum Breaker Repair Parts KitsComplete Vacuum Breaker Assembly Complete 110 Volt Solenoid Valve AssemblyConserver XL Wash Motor Assembly Other parts not shown Motor & Pump AssemblyWash Manifold Assembly Drain Solenoid Assembly Miscellaneous Parts CML Assembly Options Represents an item not shown CMR Assembly Options Hood Weldment Conserver XL2-CMR Shown Conserver XL Hood Assembly Prior to S/N 04D10286 05930-111-51-68 Conserver XL Door & Wrap Assemblies Prior to S/N 04D10286Lower Frame, Conserver XL False panel positioned in unit False Panel InstallationSection Electrical Schematics Conserver AXL 115 Volt 60 Hertz Single Phase Electrical SchematicsConserver AXL2 115 Volt 60 Hertz Single Phase Conserver AXL2-CML/CMR 115 Volt 60 Hertz Single Phase Conserver AXL2-CML/CMR 208-230 Volt 60 Hertz Single Phase Conserver Axls 115 Volt 60 Hertz Single Phase Conserver AXLS2 115 Volt 60 Hertz Single Phase Conserver XL Mechanical Timer 115 Volt 60 Hertz Single Phase Electrical Schematics Electrical Schematics Electrical Schematics Section Jackson Maintenance Repair Centers Alabama to Florida Jackson Maintenance & Repair CentersFlorida to Maryland Service COMaryland to NEW York Jackson Service CompaNEW York to Pennsylvania Certified Service Center Rons ServiceRhode Island to Wisconsin Rhode Island Whaley Foodservice GCS Service INC RepairsWisconsin to WYOMING/INTERNATIONAL

XL2-CML, XL2-CMR, AXL2-CMR, AXL2-CML, AXL2 specifications

The Jackson XL2, AXL, AXL2, AXL2-CML, and AXL2-CMR represent a remarkable lineage of advanced electric guitars designed for superior playability, tonal versatility, and innovative technology. These instruments cater to musicians of all levels, from aspiring guitarists to seasoned professionals, offering a blend of classic styling and modern features.

The Jackson XL2 model is characterized by its sleek body design and a set-neck construction that enhances sustain and allows for effortless access to higher frets. The guitar comes equipped with high-output pickups that deliver powerful tones, making it ideal for rock and metal genres. Its distinctive headstock design not only adds to its aesthetic appeal but also aids in tuning stability.

Moving to the AXL series, these guitars incorporate a double-cutaway body shape that provides excellent comfort while playing. The AXL models are known for their versatility, sporting a range of pickup configurations that allow for a wide spectrum of sounds. Players can expect a balance between aggressive tones and smooth, melodic qualities, making it suitable for various playing styles.

The AXL2 builds upon its predecessor’s capabilities, featuring an improved ergonomic design that enhances comfort during long playing sessions. The inclusion of enhanced electronics provides greater tonal options, and the instrument's lightweight construction ensures ease of handling. The AXL2-CML variant introduces a sleek matte finish, appealing to modern aesthetics while retaining robust playability.

For those seeking even more specialized features, the AXL2-CMR variant is designed with custom routing options and unique pickup placements that cater to the needs of advanced players. This version offers superior tonal clarity and response, making it perfect for intricate playing styles and complex musical compositions.

All these models showcase an attention to detail in craftsmanship, employing premium materials that ensure durability and longevity. With innovations such as locking tuners, push-pull coil-splitting features, and more, the Jackson XL2, AXL, AXL2, AXL2-CML, and AXL2-CMR cater to musicians looking for reliability and performance on stage or in the studio. Whether you are looking for raw power, tonal versatility, or refined aesthetics, these guitars meet a broad range of musical needs, making them indispensable for any guitarist.