Technical Manual (07610‐003‐78‐18)
Electrical Requirements for 66” Units
66” with 18 kW Wash Heater
|
|
| Pre‐Wash | Wash | Drive | Wash |
|
|
|
Volts | Phase | Freq | Motor | Motor | Motor | Heater | FLA | MCA | MOP |
|
|
| Amps | Amps | Amps | Amps |
|
|
|
208 | 1 | 60 | 10.2 A | 10.0 A | 1.8 A | 86.5 A | 108.5 A | 111.1 A | 121.3 A |
|
|
|
|
|
|
|
|
|
|
230 | 1 | 60 | 9.4 A | 10.0 A | 1.8 A | *71.9 A | 93.1 A | 95.6 A | 105.6 A |
|
|
|
|
|
|
|
|
|
|
240 | 1 | 60 | 9.4 A | 10.0 A | 1.8 A | 75.0 A | 96.2 A | 98.7 A | 108.7 A |
|
|
|
|
|
|
|
|
|
|
208 | 3 | 60 | 6.8 A | 8.6 A | 1.1 A | 50.0 A | 66.5 A | 68.7 A | 77.3 A |
|
|
|
|
|
|
|
|
|
|
230 | 3 | 60 | 6.4 A | 8.4 A | 1.1 A | *41.5 A | 57.4 A | 59.5 A | 67.9 A |
|
|
|
|
|
|
|
|
|
|
240 | 3 | 60 | 6.4 A | 8.4 A | 1.1 A | 43.4 A | 59.3 A | 61.4 A | 69.8 A |
|
|
|
|
|
|
|
|
|
|
460 | 3 | 60 | 3.2 A | 4.2 A | 0.6 A | **20.8 A | 28.8 A | 29.9 A | 34.1 A |
|
|
|
|
|
|
|
|
|
|
480 | 3 | 60 | 3.2 A | 4.2 A | 0.6 A | 21.7 A | 29.7 A | 30.8 A | 35.0 A |
|
|
|
|
|
|
|
|
|
|
66” Steam
|
|
| Pre‐Wash | Wash | Drive |
|
|
|
Volts | Phase | Freq | Motor | Motor | Motor | FLA | MCA | MOP |
|
|
| Amps | Amps | Amps |
|
|
|
208 | 1 | 60 | 10.2 A | 10.0 A | 1.8 A | 22.0 A | 24.6 A | 34.8 A |
|
|
|
|
|
|
|
|
|
230 | 1 | 60 | 9.4 A | 10.0 A | 1.8 A | 21.2 A | 23.7 A | 33.7 A |
|
|
|
|
|
|
|
|
|
208 | 3 | 60 | 6.8 A | 8.6 A | 1.1 A | 16.5 A | 18.7 A | 27.3 A |
|
|
|
|
|
|
|
|
|
230 | 3 | 60 | 6.4 A | 8.4 A | 1.1 A | 15.9 A | 18.0 A | 26.4 A |
|
|
|
|
|
|
|
|
|
460 | 3 | 60 | 3.2 A | 4.2 A | 0.6 A | 8.0 A | 9.1 A | 13.3 A |
|
|
|
|
|
|
|
|
|
*Denotes 240 Volt heating elements that have been down‐rated when 230 Volts is applied. ** Denotes 480 Volt heating elements that have been down‐rated when 460 Volts is applied.
Page Created: 02‐25‐2011
Revised: N/A
15