Jackson CREW SERIES RACK CONVEYOR DISHMACHINES Parts Section Overloads Wash Motors, Drive Motors

Page 29

Technical Manual (07610‐003‐78‐18)

PARTS SECTION: OVERLOADS

WASH MOTORS:

Overloads are speci ied for 3 phase units only.

For GE brand, MT03* series overloads, the process for setting is as follows: Determine the Full Load Amps for the wash motor

Set the overload at the closest setting without going over for the FLA of the motor.

The overload already compensates for the FLA and will have a set point that is 125% of the FLA. Example: Wash Motor is rated at 10.0 FLA on the data plate. The replacement MT03* overload would be set at 10.0. It would actually trip at 12.5 Amps.

Wash Motor Voltage

Part Number

GE Part Number

Blue Selector switch should be set

 

 

 

208

05945-003-76-29

MT03N

to H for manual reset.

 

 

 

230

05945-003-76-29

MT03N

 

 

 

 

 

460

05945-003-76-27

MT03L

 

 

 

 

 

DRIVE MOTORS:

Overloads are speci ied for 3 phase units only.

For GE brand, MT03* series overloads, the process for setting is as follows: Determine the Full Load Amps for the drive motor.

Set the overload at the closest setting without going over for the FLA of the motor.

The overload already compensates for the FLA and will have a set point that is 125% of the FLA. Example: Drive Motor is rated at 1.0 FLA on the data plate. The replacement MT03* overload would be set at 1.0. It would actually trip at 1.25 Amps.

Drive Motor Voltage

Part Number

GE Part Number

 

 

 

 

 

208

05945-003-76-23

MT03F

Blue Selector switch should be set

 

 

 

230

05945-003-76-23

MT03F

to H for manual reset.

460

05945-003-76-21

MT03D

 

 

 

 

 

PRE‐WASH MOTORS:

Overloads are speci ied for 3 phase units only.

For GE brand, MT03* series overloads, the process for setting is as follows: Determine the Full Load Amps for the drive motor.

Set the overload at the closest setting without going over for the FLA of the motor.

The overload already compensates for the FLA and will have a set point that is 125% of the FLA. Example: Drive Motor is rated at 6.0 FLA on the data plate. The replacement MT03* overload would be set at 6.0. It would actually trip at 7.5 Amps.

Pre-Wash Motor

Part Number

GE Part Number

 

Voltage

 

 

Blue Selector switch should be set

 

 

 

208

05945-003-76-28

MT03M

to H for manual reset.

 

 

 

230

05945-003-76-28

MT03M

 

 

 

 

 

460

05945-003-76-26

MT03K

 

 

 

 

 

NOTE: Connections should be tightened to 7 in‐lbs.

Page Created: 05‐04‐2010

Revised: 02‐25‐2011

29

Image 29
Contents Crew Steam Heated Models Crew 44S Crew 66S Installation Manual for Export UnitsPage Revision Made By Applicable ECNs Details Letter Date Speci ications Table of ContentsElectrical Diagrams and Schematics Created 06‐30‐2011 Revised N/A Ventilation Duct CONN. Unload END 4x 16ID PRE‐WASH Inlet Water Conn /2 NPT‐F Table to Table 43 8 8512 7312 2312 1118 SIDE-LOADER Side Loader DimensionsBooster Heater Steam Consumption Steam Booster Heater DimensionsHOT Water Sanitizing Available Wash Tank Heaters With 18 kW Wash Heater Pre‐Wash Drive Rise ‐ 18 KW Booster Installation Instructions Installation Instructions Installation Instructions Created 05‐04‐2010 Revised N/A Chemical Disspenser Tube Connection Points to Rinse Injector XL S Curtain Installation InstructionsOperation Instructions Created 05‐04‐2010 Revised N/A Delime Instructions PLC1 TroubleshootingLED Parts Section Control BOX ComponentsQTY PRE‐WASH Motors Parts Section Overloads Wash MotorsDrive Motors FITTING, 3/4 90 Degree QT 8510 Snap Parts Section Miscellaneous Electrical ComponentsParts Section Wash Heater & Heater Shroud Assemblies GASKET, Suction Casting Parts Section Wash Heaters Voltage Phase Part Number ContactorParts Section Door Assembly Parts Section PRE-WASH Door Assembly Overall Assembly Parts Section Door Spring AssemblyParts Section Plumbing ASSEMBLY, Main Water Inlet Parts Section Wash Tank Fill Assembly QTY Description Part Number Parts Section PRE-WASH Tank Fill AssembliesParts Section Wash Manifold and ARM Assembly Pump & Motor Assembly Parts Section PRE-WASH Manifold and ARM Assemblies Lower Manifold R‐L Units Parts Section PRE-WASH Manifold and ARM AssemblyRinse Injector Connections Parts Section Rinse AssemblyELBOW, 90 Degree 1/2 Street Brass Typical Pawl DOG With Hardware Parts Section Pawl BAR AssembliesParts Section Pawl BAR Bracket Assembly Parts Section Pawl BAR Gutter Assembly Entire Assembly Parts Section Rack Paddle AssemblyParts Section Rinse Paddle Assemblies Entire Assembly L‐REntire Assembly R‐L Parts Section Drain Assembly Parts Parts Section COVERS, Guards and Panels PRE‐WASH TOP Panel Assembly W/HANDLE 05700‐003‐82‐49Parts Section Brackets Front Rack Rail Parts Section Miscellaneous PartsParts Section Ventilation Cowl Parts Created 06‐27‐2011 Revised N/A Parts Section Drive Assembly HUB, Drive 25 *NOTE Parts Section Side LoadersDetail B TUB WELDMENT, 23 SIDE‐LOADER L‐R Drive LINKAGE, Side Loader Parts Section Side Loader Drive LinkagePLATE, Steam Coil Spacer Parts Section Steam Heating Coil AssemblyQTY Parts Section Booster Heater Option ElectricParts Section Steam Booster Heater Option ‐PLATFORM, J120 Steam Booster Booster Heater Schematic 3‐PHASE Page Page Steam Booster Heater Schematic Temperature Board PLC1 SCHEMATIC, Photocell Table Limit Switch OptionCreated 05‐04‐2010 Revised N/A Technical Manual 07610‐003‐78‐18 Created 02‐25‐2011 Revised N/A SCHEMATIC, 44 Steam Heated 208/230 VOLT, 60 HZ, 1 Phase Technical Manual 07610‐003‐78‐18 Technical Manual 07610‐003‐78‐18 Created 02‐25‐2011 Revised N/A SCHEMATIC, 66 Steam Heated 208/230 VOLT, 60 HZ, 1 Phase SVC Services Maintenance & Repair CentersHawaii Indiana Certified Service Center EMR Service Division 106 Williamsport Circle SALISBURY, MD S.T. INC Authorized Appliance Ohio Oregon Rhode Island Whaley Foodservice Repairs GCS Service INC Metro Appliance Service