Miele DA 362-75 Turning on the fan, Selecting the power level, Intensive setting, Fan performance

Page 11

Operation

Turning on the fan

^Press the joystick once to the right.

The fan runs at power level “lI” and the second indicator of the fan power scale lights.

Selecting the power level

^Press the joystick to the right, to increase the fan speed.

The corresponding indicator of the fan power scale lights.

Level "1" to "3" (green indicators) are usually sufficient for normal cooking.

Intensive setting

Level "4" (yellow indicator) should be used for a short period when frying or cooking food with a strong aroma.

Fan performance

DA 362-75:

The maximum air flow capacity is

425 cfm. Factors such as narrow duct diameter and bends will affect this value.

DA 362-110:

The maximum air flow capacity is

850 cfm. Factors such as narrow duct diameter and bends will affect this value.

Level 1 operates at 40% capacity Level 2 operates at 60% capacity Level 3 operates at 80% capacity Level 4 operates at 100% capacity

There will also be a slight decrease in airflow for hoods operated in recirculation mode due to the active charcoal filter.

11

Image 11
Contents Operating and Installation Instructions Ventilation System Contents Important Safety Instructions Use Only if Evacuate and Call the Fire DepartmentTo reduce the risk of fire only use metal ductwork InstallationAir extraction Recirculation modeFunctional description Guide to the hood Overhead lighting Grease filter Charcoal filters Main power switchFan power scale Delay Shut Down JoystickOperation Fan performance Selecting the power levelIntensive setting Turning on the fanOverhead lighting Delayed Shut DownAutomatic Safety Shut Off Turning off the fanCharcoal filters Filter timersChecking the filter timers Grease filter timerReprogramming the grease filter timer Reprogramming the timersReprogramming the charcoal filter timer Stainless steel colored controls Cleaning and careCleaning the casing Stainless steelGrease filters Cleaning the grease filtersInserting the grease filters Active charcoal filters Remove the grease filter Changing the light bulbAfter Sales Service Page Installation Instructions Disposal of an old appliance Caring for the environmentDisposal of packing material This Appliance Must be Grounded Electrical dataCut out dimensions Appliance dimensionsAppliance dimensions Installation Installation Exhaust connection Air extraction mode Non-return flapsReducing collar For DA Recirculation mode Reducing collarRecirculation connection Installing the joystick Joystick extension Electrical connection Air extraction Air extraction Page Page Page Alteration rights reserved