Miele DA 362-75 installation instructions Air extraction

Page 36

Air extraction

Never connect an exhaust hood to an active chimney, dryer vent, vent flue, or room venting ductwork. Seek professional advice before connecting an exhaust hood vent to an existing, inactive chimney or vent flue.

Important:

If the ductwork runs through rooms, ceilings, garages, etc. where temper- ature variations exist, it may need to be insulated to reduce condensation. In some cases, a condensate trap may also be required to collect and evaporate any condensate which may occur.

When installing a condensate trap, ensure that it is positioned vertically and if possible directly above the exhaust outlet.

36

Image 36
Contents Operating and Installation Instructions Ventilation System Contents Important Safety Instructions Use Evacuate and Call the Fire Department Only ifInstallation To reduce the risk of fire only use metal ductworkRecirculation mode Functional descriptionAir extraction Guide to the hood Main power switch Fan power scale Delay Shut DownJoystick Overhead lighting Grease filter Charcoal filtersOperation Selecting the power level Intensive settingTurning on the fan Fan performanceDelayed Shut Down Automatic Safety Shut OffTurning off the fan Overhead lightingFilter timers Checking the filter timersGrease filter timer Charcoal filtersReprogramming the timers Reprogramming the grease filter timerReprogramming the charcoal filter timer Cleaning and care Cleaning the casingStainless steel Stainless steel colored controlsCleaning the grease filters Grease filtersInserting the grease filters Active charcoal filters Changing the light bulb Remove the grease filterAfter Sales Service Page Installation Instructions Caring for the environment Disposal of packing materialDisposal of an old appliance Electrical data This Appliance Must be GroundedAppliance dimensions Cut out dimensionsAppliance dimensions Installation Installation Air extraction mode Non-return flaps Reducing collarExhaust connection Recirculation mode Reducing collar For DARecirculation connection Installing the joystick Joystick extension Electrical connection Air extraction Air extraction Page Page Page Alteration rights reserved