Miele DA 362-75 Functional description, Air extraction, Recirculation mode

Page 7

Functional description

The ventilation hood offers two modes of operation:

. . . Air extraction:

The air is drawn in and cleaned by the grease filters and directed outside.

The hood comes equipped with a non-return flap. This flap automatically closes when the hood is turned off so that no exchange of outside air and room air can occur.

When the hood is turned on, the air pressure of the exhaust fan auto- matically opens the flap blowing the inside air and cooking odors outside.

. . . Recirculation mode:

Air is drawn through the grease filters and active charcoal filters. The filtered air is then recirculated back into the kitchen through a vent at the top of the hood’s chimney.

The active charcoal filters may be purchased from your Miele dealer or Miele’s Technical Service Department.

Before using the hood in recirculation mode, ensure that the active charcoal filters are in place, see "Cleaning and Care".

7

Image 7
Contents Operating and Installation Instructions Ventilation System Contents Important Safety Instructions Use Only if Evacuate and Call the Fire DepartmentTo reduce the risk of fire only use metal ductwork InstallationFunctional description Recirculation modeAir extraction Guide to the hood Overhead lighting Grease filter Charcoal filters Main power switchFan power scale Delay Shut Down JoystickOperation Fan performance Selecting the power levelIntensive setting Turning on the fanOverhead lighting Delayed Shut DownAutomatic Safety Shut Off Turning off the fanCharcoal filters Filter timersChecking the filter timers Grease filter timerReprogramming the grease filter timer Reprogramming the timersReprogramming the charcoal filter timer Stainless steel colored controls Cleaning and careCleaning the casing Stainless steelGrease filters Cleaning the grease filtersInserting the grease filters Active charcoal filters Remove the grease filter Changing the light bulbAfter Sales Service Page Installation Instructions Disposal of packing material Caring for the environmentDisposal of an old appliance This Appliance Must be Grounded Electrical dataCut out dimensions Appliance dimensionsAppliance dimensions Installation Installation Reducing collar Air extraction mode Non-return flapsExhaust connection For DA Recirculation mode Reducing collarRecirculation connection Installing the joystick Joystick extension Electrical connection Air extraction Air extraction Page Page Page Alteration rights reserved