Miele DA 362-75 installation instructions Recirculation connection

Page 32

Installation

Recirculation connection

^ DA 362-75:

 

In recirculation mode, one cut out

 

must be made, where the ducting

 

ends, for the installation of the

 

recirculation vents, b.

 

If installing the hood over an island or

 

in a cabinet at ceiling height, a

 

suitable cut-out has to be made in

 

the front panel, d.

^ DA 362-110:

In recirculation mode, 2 cut outs must be made, where the ducting ends, for the installation of the recirculation vents, b.

If installing the hood over an island or in a cabinet at ceiling height, a suitable cut-out has to be made in the front panel, d.

^ The exhaust connection, a, and the recirculation vent, b, are joined together with a pipe or flexible duct, c, cut to size.

When installing the recirculation vents make sure that the slats point towards the center of the room and not to a wall or the ceiling.

^ Install the active charcoal filters (see "Cleaning and Care").

32

Image 32
Contents Operating and Installation Instructions Ventilation System Contents Important Safety Instructions Use Evacuate and Call the Fire Department Only ifInstallation To reduce the risk of fire only use metal ductworkAir extraction Recirculation modeFunctional description Guide to the hood Main power switch Fan power scale Delay Shut DownJoystick Overhead lighting Grease filter Charcoal filtersOperation Selecting the power level Intensive settingTurning on the fan Fan performanceDelayed Shut Down Automatic Safety Shut OffTurning off the fan Overhead lightingFilter timers Checking the filter timersGrease filter timer Charcoal filtersReprogramming the timers Reprogramming the grease filter timerReprogramming the charcoal filter timer Cleaning and care Cleaning the casingStainless steel Stainless steel colored controlsCleaning the grease filters Grease filtersInserting the grease filters Active charcoal filters Changing the light bulb Remove the grease filterAfter Sales Service Page Installation Instructions Disposal of an old appliance Caring for the environmentDisposal of packing material Electrical data This Appliance Must be GroundedAppliance dimensions Cut out dimensionsAppliance dimensions Installation Installation Exhaust connection Air extraction mode Non-return flapsReducing collar Recirculation mode Reducing collar For DARecirculation connection Installing the joystick Joystick extension Electrical connection Air extraction Air extraction Page Page Page Alteration rights reserved